98%
921
2 minutes
20
Several studies have reported methods to estimate the parturition date of dogs using ultrasonographic measurements. However, these prediction models were mainly determined using ultrasonographic measurements of naturally pregnant small- and medium-sized dogs, and no such studies have been performed using dogs carrying cloned fetuses produced via somatic cell nuclear transfer. The present study evaluated the abilities of three reference formulas (Luvoni and Grioni, Milani et al., and Groppetti et al.), all of which were developed using data from naturally occurring pregnancies, to accurately predict the parturition date in surrogates carrying cloned German Shepherd (GS) fetuses. All three formulas were based on the use of inner chorionic cavity diameter (ICC) measurements, obtained via ultrasonography. For evaluation, a total of 54 ICC measurements were collected from 14 pregnant bitches carrying cloned GS fetuses. We found that the clinical accuracy of the breed-specific Groppetti et al. formula was highest among those of the three formulas tested, with 87% and 100% of the estimated parturition dates (calculated based on the ICC measurements) being within 1 and 2 days, respectively, of the actual delivery date. By contrast, the Luvoni and Grioni formula showed relatively low accuracy, and the Milani et al. formula showed higher accuracy than that reported previously for natural pregnancies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8498844 | PMC |
http://dx.doi.org/10.1292/jvms.21-0154 | DOI Listing |
J Refract Surg
September 2025
From the Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany and.
Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.
Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).
Am J Ophthalmol
September 2025
Dean McGee Eye Institute, University of Oklahoma, Oklahoma City, Oklahoma, USA. Electronic address:
Purpose: To compare refractive prediction accuracy using simulated keratometry (SimK) measurements obtained from a Scheimpflug tomographer (Pentacam AXL, Oculus) versus keratometry (K) measurements obtained from an optical biometer utilizing telecentric keratometry (IOLMaster 700 (IOLM700), Carl Zeiss Meditec AG) applied to modern IOL power calculation formulas.
Design: Retrospective accuracy and validity analysis METHODS: Setting: Private practice center STUDY POPULATION: Five hundred eighty-nine eyes with preoperative SimK and K measurements undergoing phacoemulsification and implantation of monofocal IOL (Clareon SY60WF IOL, Alcon Laboratories, Inc.).
Phys Chem Chem Phys
September 2025
School of Physics, Changchun University of Science and Technology, Changchun 130022, China.
The design of carbon allotropes that simultaneously exhibit mechanical robustness and quantum functionalities remains a longstanding challenge. Here, we report a comprehensive first-principles study of cT16, a three-dimensional sp-hybridized carbon network with topologically interlinked graphene-like sheets. The structure features high ideal tensile and shear strengths, with pronounced anisotropy arising from strain-induced bond rehybridization and interlayer slipping mechanisms.
View Article and Find Full Text PDFDocosahexaenoic acid (DHA) is essential for brain and cognitive development in toddlers; however, global intakes often fall below recommended levels. This study evaluated the bioavailability of DHA from commercial toddler formulas fortified with either microencapsulated high-DHA fish oil powder or high-DHA fish oil. A double-blind, randomized controlled trial was conducted in 120 healthy Indonesian toddlers aged 2-3 years.
View Article and Find Full Text PDFJ Hand Surg Glob Online
November 2025
Institute of Orthopedics and Traumatology, Military Hospital 175, Ho Chi Minh City, Vietnam.
Purpose: We present a novel protocol for wrist function assessment that integrates both objective factors (range of motion and grip strength) and subjective domains (pain, motor function, and quality of life) into the composite Wrist Function Score - 175 (WFS-175) score.
Methods: The protocol consists of three main steps: (1) data collection, which involves measuring the wrist range of motion in six directions using a goniometer and grip strength, including maximum strength, endurance, and recovery, using a Jamar dynamometer, alongside concurrent subjective assessment with a standardized questionnaire; (2) standardization of all data onto a unified scoring scale, applying a linear formula to calculate the total WFS-175 score (maximum 175 points), with the following components: range of motion (30 points), grip strength (40 points), pain (25 points), motor function (40 points), and quality of life (40 points); and (3) input of results into the AppSheet/Google Sheets system, which provides automated calculation, storage, reporting, and graphical visualization for longitudinal tracking of functional recovery.
Results: This protocol yields a standardized assessment form that enables precise calculation of the WFS-175 score.