98%
921
2 minutes
20
Objective: To determine the optimal and safest proximal sealing length (PSL) during thoracic endovascular aortic repair (TEVAR), depending on anatomical aortic arch types and proximal landing zones (LZs).
Methods: This was a single centre retrospective observational study of consecutive TEVAR patients (2008-2020). All aortic pathologies requiring Ishimaru landing zone (LZ) 0 - 3 were included; results were stratified by aortic arch type. The PSL was measured as the length of complete aortic wall to endograft apposition at the level of the proximal neck. The primary endpoint was proximal failure (type 1A endoleak, endograft migration, or re-intervention requiring proximal graft extension). Freedom from proximal failure was estimated with Kaplan-Meier curves. An "optimal" sealing length (PSL cutoff maximising sensitivity + specificity for proximal failure) and "safest length" (PSL cutoff determining ≥ 90% sensitivity) were identified using receiver operating characteristic curve analysis.
Results: One hundred and forty patients received TEVAR; mean ± standard deviation PSL was 29 ± 9 mm. Freedom from proximal endograft failure at five years (median 31 months) was 82.4% (95% confidence interval [CI] 72 - 95); the shorter the PSL, the greater was the risk of failure (hazard ratio 0.90, 95% CI 0.84 - 0.97; p = .004). Overall optimal and safest PSL were 25 mm (sensitivity 78%, specificity 66%) and 30 mm (sensitivity 92%, specificity 30%), respectively. In type I arch, the optimal PSL was 22 mm (sensitivity 50%, specificity 87%). In type II, the optimal PSL was 25 mm (sensitivity 89%, specificity 59%) overall and 27 mm for type II/LZ 2 - 3 (sensitivity 31%, specificity 68%). For type III, the optimal PSL was 27 mm (sensitivity 80%, specificity 87%); the safest was 30 mm (sensitivity 100%, specificity 61%) In type III/LZ 2 - 3, the optimal PSL was 27 mm (sensitivity 31%, specificity 68%) and safest was 30 mm (sensitivity 100%, specificity 55%).
Conclusion: A 20 mm PSL may be acceptable only for type I arches. For types II/III, that represent the majority of cases, a 25 - 30 mm PSL may be required for a safe and durable TEVAR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejvs.2021.05.012 | DOI Listing |
Adv Mater
September 2025
Key Laboratory of In-Fiber Integrated Optics of Ministry of Education, College of Physics and Optoelectronic Engineering, Harbin Engineering University, Harbin, 150001, China.
Recently, joint replacement surgery is facing significant challenges of patient dissatisfaction and the need for revision procedures. In-situ monitoring of stress stability at the site of artificial joint replacement during postoperative evaluation is important. Mechanoluminescence (ML), a novel "force to light" conversion technology, may be used to monitor such bio-stress within tissues.
View Article and Find Full Text PDFProg Nucl Magn Reson Spectrosc
February 2025
Brown Boveri Platz 4, 5400 Baden, Switzerland.
Zero and ultralow-field nuclear magnetic resonance (ZULF NMR) is an NMR modality where experiments are performed in fields at which spin-spin interactions within molecules and materials are stronger than Zeeman interactions. This typically occurs at external fields of microtesla strength or below, considerably smaller than Earth's field. In ZULF NMR, the measurement of spin-spin couplings and spin relaxation rates provides a nondestructive means for identifying chemicals and chemical fragments, and for conducting sample or process analyses.
View Article and Find Full Text PDFSleep Breath
September 2025
Université Paris Cité, NeuroDiderot, Inserm U1141, Paris, F-75019, France.
Purpose: obstructive sleep apnea is underdiagnosed due to limited access to polysomnography (PSG). We aimed to assess the performances of Apneal, an application recording sound and movements thanks to a smartphone's microphone, accelerometer and gyroscope, to estimate patients' apnea-hypopnea index (AHI).
Methods: monocentric proof-of-concept study with a first manual scoring step, then automatic detection of respiratory events from recorded signals using a sequential deep-learning model (version 0.
Imaging Neurosci (Camb)
September 2025
Physics for Medicine Paris, Inserm, ESPCI Paris-PSL, CNRS, Paris, France.
Functional ultrasound (fUS) is a promising imaging method for evaluating brain function in animals and human neonates. fUS images local cerebral blood volume changes to map brain activity. One application of fUS imaging is the quantification of functional connectivity (FC), which characterizes the strength of the connections between functionally connected brain areas.
View Article and Find Full Text PDFGlobal Spine J
August 2025
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
Study DesignRetrospective Study.ObjectivesTo compare the efficacy of pedicle Hounsfield unit (HU) values and pedicle bone quality (PBQ) scores in predicting pedicle screw loosening (PSL) after posterior lumbar interbody fusion (PLIF) in elderly patients and to identify the most discriminative bone mineral density (BMD) assessment indicator.MethodsThis retrospective analysis included 275 consecutive patients who underwent PLIF.
View Article and Find Full Text PDF