Article Abstract

The standard method for obtaining samples during endoscopic ultrasonography (EUS) is fine-needle aspiration (FNA), the accuracy of which can be affected by the presence of a cytopathologist in endoscopy room (rapid on-site evaluation [ROSE]). With the introduction of fine-needle biopsy (FNB), macroscopic on-site evaluation (MOSE) of a acquired specimen has been proposed. Only a few studies have evaluated the role of MOSE and in all except one, a 19G needle was used. Our primary aim was to evaluate the diagnostic yield and accuracy of MOSE with different needle sizes and the secondary aim was to identify factors influencing the yield of MOSE. Data from patients who underwent EUS-FNB for solid lesions, with MOSE evaluation of the specimen, were collected in six endoscopic referral centers. A total of 378 patients (145 F and 233 M) were enrolled. Needles sizes used during the procedures were 20G (42 %), 22G (45 %), and 25G (13 %). The median number of needle passes was two (IQR 2-3). The overall diagnostic yield of MOSE was of 90 % (confidence interval [CI] 86 %-92 %). On multivariable logistic regression analysis, variables independently associated with the diagnostic yield of MOSE were a larger needle diameter (20G vs. 25G, OR 11.64, 95 %CI 3.5-38.71; 22G vs. 25G, OR 6.20, 95 %CI 2.41-15.90) and three of more needle passes (OR 3.39, 95 %CI 1.38-8.31). MOSE showed high diagnostic yield and accuracy. Its yield was further increased if performed with a large size FNB needles and more than two passes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8159577PMC
http://dx.doi.org/10.1055/a-1395-7129DOI Listing

Publication Analysis

Top Keywords

diagnostic yield
16
on-site evaluation
12
yield mose
12
mose
9
macroscopic on-site
8
evaluation mose
8
solid lesions
8
yield accuracy
8
needle passes
8
needle
6

Similar Publications

The aim of this in-vitro study was to verify which field of view (FOV) in cone-beam computed tomography (CBCT) yields greater accuracy in the detection of internal root resorption (IRR) volume, in comparison to the gold standard of micro-computed tomography (micro-CT) and to a physical method. Twenty-five extractedsingle-rooted teeth were scanned by CBCT with two different FOV parameters (6x6-FOV and 10x10-FOV) and via micro-CT. The volume of dental hard tissue was measured on these images.

View Article and Find Full Text PDF

The utility of thymus and spleen ultrasound in the early prediction of neonatal sepsis.

J Neonatal Perinatal Med

September 2025

Muratpaşa District Health Directorate, Antalya, Turkey.

BackgroundThis investigation aimed to determine the utility of postnatal, ultrasonographically-derived dimensions of the thymus and spleen as imaging indicators for the prediction of early-onset neonatal sepsis (EOS).Material and MethodIn this case-control study, 30 term neonates diagnosed with Early-Onset Sepsis (EOS), based on European Medicines Agency (EMA) criteria, were compared to 30 healthy, matched control neonates. All participants underwent ultrasonography to quantify thymic and splenic dimensions.

View Article and Find Full Text PDF

Predicting the future risk and outcomes of severe heart failure and coronary artery disease with machine learning in the UK Biobank Cohort.

PLoS One

September 2025

Department of Medicine, The Red Rogers Centre for Heart Research, Peter Munk Cardiac Centre, University Health Network, University of Toronto, Toronto, Ontario, Canada.

Background: In order to seriously impact the global burden of heart failure (HF) and coronary artery disease (CAD), identifying at-risk individuals as early as possible is vital. Risk calculator tools in wide clinical use today are informed by traditional statistical methods that have historically yielded only modest prediction accuracy.

Methods: This study uses machine learning algorithms to generate predictions models for the development and progression of severe HF and CAD.

View Article and Find Full Text PDF

There are limited data regarding photopatch testing (PPT) in Israel. To investigate the prevalence of positive reactions and concurrent diagnosis of patients that underwent PPT in a single center in Israel. Retrospective cohort study that included all patients that were suspected of having contact dermatitis and underwent patch testing with the European baseline series (EBS) and additionally were selectively PPT with the Scandinavian/European baseline photopatch series in a tertiary medical center in Israel (2009-2023).

View Article and Find Full Text PDF

Importance: Behavioral variant frontotemporal dementia (bvFTD), the most common subtype of FTD, is a leading form of early-onset dementia worldwide. Accurate and timely diagnosis of bvFTD is frequently delayed due to symptoms overlapping with common psychiatric disorders, and interest has increased in identifying biomarkers that may aid in differentiating bvFTD from psychiatric disorders.

Objective: To summarize and critically review studies examining whether neurofilament light chain (NfL) in cerebrospinal fluid (CSF) or blood is a viable aid in the differential diagnosis of bvFTD vs psychiatric disorders.

View Article and Find Full Text PDF