A microfluidic chip for electrochemical impedance spectroscopy (EIS) is presented as bio-sensor for label-free detection of proteins by using the example of cardiac troponin I. Troponin I is one of the most specific diagnostic serum biomarkers for myocardial infarction. The microfluidic impedance biosensor chip presented here consists of a microscope glass slide serving as base plate, sputtered electrodes, and a polydimethylsiloxane (PDMS) microchannel. Electrode functionalization protocols were developed considering a possible charge transfer through the sensing layer, in addition to analyte-specific binding by corresponding antibodies and reduction of nonspecific protein adsorption to prevent false-positive signals. Reagents tested for self-assembled monolayers (SAMs) on gold electrodes included thiolated hydrocarbons and thiolated oligonucleotides, where SAMs based on the latter showed a better performance. The corresponding antibody was covalently coupled on the SAM using carbodiimide chemistry. Sampling and measurement took only a few minutes. Application of a human serum albumin (HSA) sample, 1000 ng/mL, led to negligible impedance changes, while application of a troponin I sample, 1 ng/mL, led to a significant shift in the Nyquist plot. The results are promising regarding specific detection of clinically relevant concentrations of biomarkers, such as cardiac markers, with the newly developed microfluidic impedance biosensor chip.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8001378PMC
http://dx.doi.org/10.3390/bios11030080DOI Listing

Publication Analysis

Top Keywords

microfluidic impedance
12
impedance biosensor
12
self-assembled monolayers
8
label-free detection
8
detection proteins
8
biosensor chip
8
ng/ml led
8
microfluidic
4
biosensor chips
4
chips sensing
4

Similar Publications

Microfluidic impedance flow cytometry has functioned as an enabling instrument in single-cell analysis, which, however, suffers from the limiting tradeoff between high sensitivity and clogging-free operation. In order to address this issue, this study presented a microfluidic impedance flow cytometer based on three-dimensional (3D) hydrodynamic focusing, in which the crossflow of conductive sample fluids and insulating sheath fluids was leveraged to centralize and restrict electric field lines to the sample fluid, thereby achieving high impedance sensitivity of single cells without the concern of channel blockage. Different from conventional impedance flow cytometry, in this study, impedance amplitude dips (rather than pulse singles) generated by single microparticles traveling through the 3D hydrodynamic focusing region were experimentally validated using microbeads.

View Article and Find Full Text PDF

Blood tests are widely used to assess a patient's health status. Microfluidics, in combination with electrochemical impedance spectroscopy (MEIS), opens up great prospects for blood analysis. This study aimed to improve the MEIS blood tests.

View Article and Find Full Text PDF

Impedance flow cytometry is a widely used label-free technique for single-cell analysis; however, its limited sensitivity and lack of universality have hindered its ability to replace conventional flow cytometry. In this study, we propose an adaptive microfluidic channel platform that dynamically adjusts the channel height to improve both measurement performance and system versatility. We found that reducing the channel height by one-third effectively decreases the distance between particles and the sensing electrodes, resulting in an average 3.

View Article and Find Full Text PDF

This study introduces a rapid, label-free impedance-based approach for evaluating the effects of NQO1-targeting drugs on cancer cells. Departing from the traditional reliance on adherent cell cultures, the method utilizes suspended cells to eliminate the need for cell seeding, significantly reducing the total assay duration from over 48 h to less than 24 h. Unlike conventional assays like CCK8, which rely on end point metabolic measurements, impedance spectroscopy enables real-time, label-free monitoring of cellular responses by detecting dynamic changes in cell membrane integrity and intracellular conductivity.

View Article and Find Full Text PDF

Organ-on-chip (OOC) systems that recapitulate microenvironmental features like coculture, fluid shear stress, and extracellular matrix are useful for modeling biological barriers. OOC barrier integrity measurements are often done by trans-endothelial/epithelial electrical resistance (TEER) measurement, but this approach is confounded by nonuniform current distribution and interference from biomaterials typical to such systems. We addressed this gap by incorporating gold leaf porous membrane electrical cell-substrate impedance sensing (PM-ECIS) electrodes (diameters of 250, 500, or 750 μm) into a biocompatible tape-based barrier-on-chip (BOC) platform.

View Article and Find Full Text PDF