Article Abstract

. See-through head-mounted displays (HMDs) can be used to view fluoroscopic imaging during orthopedic surgical procedures. The goals of this study were to determine whether HMDs reduce procedure time, number of fluoroscopic images required, or number of head turns by the surgeon compared with standard monitors. . Sixteen orthopedic surgery residents each performed fluoroscopy-guided drilling of 8 holes for placement of tibial nail distal interlocking screws in an anatomical model, with 4 holes drilled while using HMD and 4 holes drilled while using a standard monitor. Procedure time, number of fluoroscopic images needed, and number of head turns by the resident during the procedure were compared between the 2 modalities. Statistical significance was set at < .05. . Mean (SD) procedure time did not differ significantly between attempts using the standard monitor (55 [37] seconds) vs the HMD (56 [31] seconds) ( = .73). Neither did mean number of fluoroscopic images differ significantly between attempts using the standard monitor vs the HMD (9 [5] images for each) ( = .84). Residents turned their heads significantly more times when using the standard monitor (9 [5] times) vs the HMD (1 [2] times) ( < .001). . Head-mounted displays lessened the need for residents to turn their heads away from the surgical field while drilling holes for tibial nail distal interlocking screws in an anatomical model; however, there was no difference in terms of procedure time or number of fluoroscopic images needed using the HMD compared with the standard monitor.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1553350620987978DOI Listing

Publication Analysis

Top Keywords

standard monitor
20
procedure time
16
number fluoroscopic
16
fluoroscopic images
16
time number
12
fluoroscopic imaging
8
imaging orthopedic
8
orthopedic surgery
8
head-mounted displays
8
number head
8

Similar Publications

Antitumor Effects of Doxorubicin-Loaded Cellulose Nanoparticles in the Rabbit VX2 Liver Tumor Model.

Cardiovasc Intervent Radiol

September 2025

Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82, Gumi-ro 173Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea.

Purpose: To evaluate the preclinical efficacy and safety of transarterial chemoembolization (TACE) using doxorubicin-loaded biocompatible cellulose nanoparticles in a rabbit VX2 liver tumor model.

Materials And Methods: Following institutional animal care committee approval, 23 rabbits with VX2 liver tumors were randomized into three groups: Group A (n = 9) received doxorubicin-loaded cellulose nanoparticles with ethiodized oil; Group B (n = 9) received doxorubicin with ethiodized oil; and Group C (n = 5) served as untreated controls. Tumor size was monitored via ultrasound for 4 weeks, and serum liver enzymes (aspartate transaminase and alanine transaminase) were measured on days 1, 3, and 7 to assess hepatotoxicity.

View Article and Find Full Text PDF

Karst water bodies are vital groundwater resources particularly vulnerable to pollution. Protecting their water quality requires documenting contaminants traditionally associated with anthropogenic activities (metals, nutrients, and fecal indicator bacteria) as well as emerging contaminants, such as antibiotic-resistant organisms (AROs) and perfluoroalkyl substances (PFAS). This study detected contaminants in karst-associated water bodies on the Yucatán Peninsula, including 10 sinkholes (cenotes) and one submarine groundwater discharge (SGD) site.

View Article and Find Full Text PDF

Objective: To determine the use of Air-Test in ventilated, anaesthetized dogs for evaluating oxygen uptake and to determine its potential utility in guiding the decision to perform an alveolar recruitment manoeuvre (ARM).

Study Design: Retrospective cohort study.

Animals: A total of 25 client-owned dogs undergoing general anaesthesia.

View Article and Find Full Text PDF

[Cough frequency monitoring: current technologies and clinical research applications].

Zhonghua Jie He He Hu Xi Za Zhi

September 2025

Department of Respiratory and Critical Care Medicine, the First Affiliated Hospital of Guangzhou Medical University, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, State Key Laboratory of Respiratory Disease, Guangzhou Institute of Respiratory He

Cough is a common symptom of many respiratory diseases, and parameters such as frequency, intensity, type and duration play important roles in disease screening, diagnosis and prognosis. Among these, cough frequency is the most widely applied metric. In current clinical practice, cough severity is primarily assessed based on patients' subjective symptom descriptions in combination with semi-structured questionnaires.

View Article and Find Full Text PDF

To explore the feasibility and accuracy of predicting respiratory tract infections (RTIs) using physiological data obtained from consumer-grade smartwatches. The study used smartwatches and paired mobile applications to continuously collect physiological parameters while participants slept. A personalized baseline model was established using multi-day data, followed by the construction of RTIs risk prediction algorithm based on deviations from physiological parameter trends.

View Article and Find Full Text PDF