98%
921
2 minutes
20
Adaptive optics (AO) based ophthalmic imagers, such as scanning laser ophthalmoscopes (SLO) and optical coherence tomography (OCT), are used to evaluate the structure and function of the retina with high contrast and resolution. Fixational eye movements during a raster-scanned image acquisition lead to intra-frame and intra-volume distortion, resulting in an inaccurate reproduction of the underlying retinal structure. For three-dimensional (3D) AO-OCT, segmentation-based and 3D correlation based registration methods have been applied to correct eye motion and achieve a high signal-to-noise ratio registered volume. This involves first selecting a reference volume, either manually or automatically, and registering the image/volume stream against the reference using correlation methods. However, even within the chosen reference volume, involuntary eye motion persists and affects the accuracy with which the 3D retinal structure is finally rendered. In this article, we introduced reference volume distortion correction for AO-OCT using 3D correlation based registration and demonstrate a significant improvement in registration performance via a few metrics. Conceptually, the general paradigm follows that developed previously for intra-frame distortion correction for 2D raster-scanned images, as in an AOSLO, but extended here across all three spatial dimensions via 3D correlation analyses. We performed a frequency analysis of eye motion traces before and after intra-volume correction and revealed how periodic artifacts in eye motion estimates are effectively reduced upon correction. Further, we quantified how the intra-volume distortions and periodic artifacts in the eye motion traces, in general, decrease with increasing AO-OCT acquisition speed. Overall, 3D correlation based registration with intra-volume correction significantly improved the visualization of retinal structure and estimation of fixational eye movements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7771894 | PMC |
http://dx.doi.org/10.1364/OE.410374 | DOI Listing |
Front Cell Neurosci
August 2025
Stem Cell Research Center, University of California, Irvine, Irvine, CA, United States.
Objective: To assess the safety and tolerability of intravitreal injection of human retinal progenitor cells (RPCs) at multiple dose levels in adults with non-syndromic retinitis pigmentosa (RP).
Design: A prospective, multicenter, open-label, single-arm, Phase I/IIa safety study of RPCs in adults with RP ( = 28). Two patient cohorts were studied: Cohort 1: BCVA no better than 20/200 and no worse than Hand Motions, and Cohort 2: BCVA no better than 20/40 and no worse than 20/200).
Clin Ophthalmol
September 2025
Helen Keller Eye Research Foundation, Birmingham, AL, USA.
Rhegmatogenous retinal detachment (retinal detachment, RD) is the most common cause of spontaneous vision loss in aging eyes that were seeing normally until the moment of its occurrence. Causative retinal breaks usually occur in the form of peripheral tears at the vitreous base, resulting from traction exerted by the aging vitreous as it detaches posteriorly. Peripheral encircling laser retinopexy increases retinal resistance to vitreous traction in high-risk eyes.
View Article and Find Full Text PDFMicrosyst Nanoeng
September 2025
Department of Ophthalmology, Key Laboratory of Precision Medicine for Eye Diseases of Zhejiang Province, Center for Rehabilitation Medicine,, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, 314408, China.
Retinal surgery is one of the most delicate and complex operations, which is close to or even beyond the physiological limitation of the human hand. Robots have demonstrated the ability to filter hand tremors and motion scaling which has a promising output in microsurgery. Here, we present a novel soft micron accuracy robot (SMAR) for retinal surgery and achieve a more precise and safer operation.
View Article and Find Full Text PDFJ Vis Exp
August 2025
Marianne Bernadotte Centrum, Department for Clinical Neuroscience, Karolinska Institutet; St Erik Eye Hospital.
The present protocol evaluates the relative impact of visual and vestibular inputs during roll plane rotations using optokinetic, vestibular, and combined visuovestibular stimulations. Subjects underwent isolated visual rotations, whole-body vestibular rotations in darkness, and visuovestibular stimulations combining static visual scenes with head rotations. Dynamic and static eye movement gains, absolute amplitudes, velocities, and accelerations were measured alongside perceptual responses.
View Article and Find Full Text PDFAm Psychol
September 2025
State Key Laboratory of Cognitive Science and Mental Health, Institute of Psychology, Chinese Academy of Sciences.
In cluttered and complex natural scenes, selective attention enables the visual system to prioritize relevant information. This process is guided not only by perceptual cues but also by imagined ones. The current research extends the imagery-induced attentional bias to the unconscious level and reveals its cross-category applicability between different social cues (e.
View Article and Find Full Text PDF