Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Adaptive optics (AO) based ophthalmic imagers, such as scanning laser ophthalmoscopes (SLO) and optical coherence tomography (OCT), are used to evaluate the structure and function of the retina with high contrast and resolution. Fixational eye movements during a raster-scanned image acquisition lead to intra-frame and intra-volume distortion, resulting in an inaccurate reproduction of the underlying retinal structure. For three-dimensional (3D) AO-OCT, segmentation-based and 3D correlation based registration methods have been applied to correct eye motion and achieve a high signal-to-noise ratio registered volume. This involves first selecting a reference volume, either manually or automatically, and registering the image/volume stream against the reference using correlation methods. However, even within the chosen reference volume, involuntary eye motion persists and affects the accuracy with which the 3D retinal structure is finally rendered. In this article, we introduced reference volume distortion correction for AO-OCT using 3D correlation based registration and demonstrate a significant improvement in registration performance via a few metrics. Conceptually, the general paradigm follows that developed previously for intra-frame distortion correction for 2D raster-scanned images, as in an AOSLO, but extended here across all three spatial dimensions via 3D correlation analyses. We performed a frequency analysis of eye motion traces before and after intra-volume correction and revealed how periodic artifacts in eye motion estimates are effectively reduced upon correction. Further, we quantified how the intra-volume distortions and periodic artifacts in the eye motion traces, in general, decrease with increasing AO-OCT acquisition speed. Overall, 3D correlation based registration with intra-volume correction significantly improved the visualization of retinal structure and estimation of fixational eye movements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7771894PMC
http://dx.doi.org/10.1364/OE.410374DOI Listing

Publication Analysis

Top Keywords

eye motion
20
correlation based
16
based registration
16
retinal structure
12
reference volume
12
intra-volume distortion
8
ao-oct correlation
8
fixational eye
8
eye movements
8
distortion correction
8

Similar Publications

Objective: To assess the safety and tolerability of intravitreal injection of human retinal progenitor cells (RPCs) at multiple dose levels in adults with non-syndromic retinitis pigmentosa (RP).

Design: A prospective, multicenter, open-label, single-arm, Phase I/IIa safety study of RPCs in adults with RP ( = 28). Two patient cohorts were studied: Cohort 1: BCVA no better than 20/200 and no worse than Hand Motions, and Cohort 2: BCVA no better than 20/40 and no worse than 20/200).

View Article and Find Full Text PDF

Vitrectomy as a Prevention for Retinal Detachment in High-Risk Eyes.

Clin Ophthalmol

September 2025

Helen Keller Eye Research Foundation, Birmingham, AL, USA.

Rhegmatogenous retinal detachment (retinal detachment, RD) is the most common cause of spontaneous vision loss in aging eyes that were seeing normally until the moment of its occurrence. Causative retinal breaks usually occur in the form of peripheral tears at the vitreous base, resulting from traction exerted by the aging vitreous as it detaches posteriorly. Peripheral encircling laser retinopexy increases retinal resistance to vitreous traction in high-risk eyes.

View Article and Find Full Text PDF

A soft micron accuracy robot design and clinical validation for retinal surgery.

Microsyst Nanoeng

September 2025

Department of Ophthalmology, Key Laboratory of Precision Medicine for Eye Diseases of Zhejiang Province, Center for Rehabilitation Medicine,, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, 314408, China.

Retinal surgery is one of the most delicate and complex operations, which is close to or even beyond the physiological limitation of the human hand. Robots have demonstrated the ability to filter hand tremors and motion scaling which has a promising output in microsurgery. Here, we present a novel soft micron accuracy robot (SMAR) for retinal surgery and achieve a more precise and safer operation.

View Article and Find Full Text PDF

The present protocol evaluates the relative impact of visual and vestibular inputs during roll plane rotations using optokinetic, vestibular, and combined visuovestibular stimulations. Subjects underwent isolated visual rotations, whole-body vestibular rotations in darkness, and visuovestibular stimulations combining static visual scenes with head rotations. Dynamic and static eye movement gains, absolute amplitudes, velocities, and accelerations were measured alongside perceptual responses.

View Article and Find Full Text PDF

Cross-category attentional biases driven by visual mental imagery of social cues.

Am Psychol

September 2025

State Key Laboratory of Cognitive Science and Mental Health, Institute of Psychology, Chinese Academy of Sciences.

In cluttered and complex natural scenes, selective attention enables the visual system to prioritize relevant information. This process is guided not only by perceptual cues but also by imagined ones. The current research extends the imagery-induced attentional bias to the unconscious level and reveals its cross-category applicability between different social cues (e.

View Article and Find Full Text PDF