Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness.

J Mech Behav Biomed Mater

Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada.

Published: March 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological error of the most common methods used to predict long-bone bending stiffness, more specifically, flexural rigidity (EI). Functional testing of a bi-material porcine bone surrogate, developed in a previous study, was conducted under four-point bending test conditions. The bone surrogate was imaged using computed tomography (CT) with an isotropic voxel resolution of 0.625 mm. Digital image correlation (DIC) of the bone surrogate was used to quantify the methodological error between experimental, analytical, and computational methods used to calculate EI. These methods include the application of Euler Bernoulli beam theory to mechanical testing and DIC data; the product of the bone surrogate composite bending modulus and second area moment of inertia; and finite element analysis (FEA) using computer-aided design (CAD) and CT-based geometric models. The methodological errors of each method were then compared. The results of this study determined that CAD-based FEA was the most accurate determinant of bone EI, with less than five percent difference in EI to that of the DIC and consistent reproducibility of the measured displacements for each load increment. CT-based FEA was most accurate for axial strains. Analytical calculations overestimated EI and mechanical testing was the least accurate, grossly underestimating flexural rigidity of long-bones.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2020.104253DOI Listing

Publication Analysis

Top Keywords

bone surrogate
16
experimental analytical
8
analytical computational
8
computational methods
8
long-bone bending
8
bending stiffness
8
quantify methodological
8
methodological error
8
flexural rigidity
8
mechanical testing
8

Similar Publications

Microstructure of the anterior iliac Spine: Identification of trends and relation to fracture tolerance.

J Mech Behav Biomed Mater

September 2025

Center for Applied Biomechanics, University of Virginia, 4040 Lewis and Clark Drive, Charlottesville, VA, 22911, United States.

Seatbelt-induced pelvic iliac wing injuries have been observed since the 1970s, but only recently has there been quantification of fracture tolerance and injury risk of the iliac wing. Previous studies have shown a wide variation in iliac wing fracture tolerance with no significant relationships to pelvis size, sex, or other factors. A weighted average bone density (BD) calculation of the entire iliac wing produced the best predictive performance of fracture tolerance in parametric (Weibull) survival models.

View Article and Find Full Text PDF

The use of cementless total knee arthroplasty (TKA) has significantly increased over the past decade. However, there is no objective criteria or consensus on parameters for patient selection for cementless TKA. The purpose of this study was to develop a machine learning model based on patient and radiographic parameters that could identify patients indicated for cementless TKA.

View Article and Find Full Text PDF

Objectives: This study aims to evaluate the evolution of subchondral sacroiliac joint (SIJ) sclerosis from pregnancy to 12 months postpartum, and to explore preceding and concomitant magnetic resonance imaging (MRI) features, potentially indicating osteitis condensans ilii (OCI).

Methods: One hundred three first-time mothers were recruited for serial SIJ MRIs. MRI scans were performed at pregnancy weeks 20 and 32, and at 3, 6, and 12 months postpartum.

View Article and Find Full Text PDF

Minimal Residual Disease Negativity as the Primary Goal of Multiple Myeloma Therapy.

Drugs

September 2025

Section of Hematology/Oncology, University of Chicago, 5841 S. Maryland Ave, MC 2115, Chicago, IL, 60637, USA.

Measurable (or minimal) residual disease (MRD) testing offers critical prognostic insight in multiple myeloma (MM), surpassing conventional response criteria. While bone-marrow-based assays are most commonly performed, MRD assessment in peripheral blood and advanced imaging may add complementary value. A comprehensive approach, integrating serial MRD testing across compartments, may offer the most accurate appraisal of disease burden.

View Article and Find Full Text PDF

Accurate quantification of bone mineral, organic, and water phases is critical for evaluating bone quality, assessing fracture risk, and diagnosing skeletal diseases. Dual-energy computed tomography (DECT) holds promise for decomposing these phases but fundamentally relies on precise linear attenuation coefficients (LACs) for each phase. Existing surrogate-based imaging methods-typically assuming fixed phase attenuation coefficients-fail to reflect the compositional heterogeneity of native bone, leading to systematic errors in decomposition.

View Article and Find Full Text PDF