98%
921
2 minutes
20
Introduction: Current volume measurement techniques, for the orbit, are time-consuming and involve complex assessments, which prevents their routine clinical use. In this study, we evaluate the applicability and efficacy of stereology and planimetry in orbital volume measurements using magnetic resonance imaging (MRI).
Materials And Methods: Prospective imaging study using MRI. Sheep craniums and human subjects were evaluated. Water-filling measurements were performed in animal skulls, as the standard validation technique. Planimetry and stereology techniques were used in each dataset. Intraobserver and interobserver reliability testing were applied.
Results: In stereology customization, 1/6 systematic sampling scheme was determined as optimal with acceptable coefficient of error (3.09%) and low measurement time (1.2 min). In sheep craniums, the mean volume measured by water displacement, planimetry, and stereology was 17.81 ± 0.59 cm, 18.53 ± 0.24 cm, and 19.19 ± 0.17 cm, respectively. Planimetric and stereological methods were highly correlated ( = 0.94; ≈ 0.001). The mean difference of the orbital volume using planimetry and stereology was 0.316 ± 0.168 cm. In human subjects, using stereology, the mean orbital volume was found to be 19.62 ± 0.2 cm with a CE of 3.91 ± 0.15%.
Conclusions: The optimized stereological method was found superior to manual planimetry in terms of user effort and time spent. Stereology sampling of 1/6 was successfully applied in human subjects and showed strong correlation with manual planimetry. However, optimized stereological method tended to overestimate the orbital volume by about 1 cc, a considerable limitation to be taken in clinical practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7518488 | PMC |
http://dx.doi.org/10.4103/njms.NJMS_9_20 | DOI Listing |
Cell Rep Med
August 2025
Center for Biomedical-photonics and Molecular Imaging, Advanced Diagnostic-Therapy Technology and Equipment Key Laboratory of Higher Education Institutions in Shaanxi Province, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi 710126, China; Engineering Research Center of Mole
Rapid identification and accurate diagnosis are critical for individuals with acute leukemia (AL). Here, we propose a combined deep learning and surface-enhanced Raman scattering (DL-SERS) classification strategy to achieve rapid and sensitive identification of AL with various subtypes and genetic abnormalities. More than 390 of cerebrospinal fluid (CSF) samples are collected as targets, encompassing healthy control, AL patients, and individuals with other diseases.
View Article and Find Full Text PDFRev Sci Instrum
September 2025
National Time Service Center, Chinese Academy of Sciences, Xi'an 710600, China.
We report the design and in-orbit demonstration of a compact optical system for a 87Sr optical lattice clock aboard the Chinese Space Station. This system adopts a compact and robust vertically stacked architecture with a total volume of 0.11 m3 and a mass of 53.
View Article and Find Full Text PDFJ Craniofac Surg
September 2025
Department of Plastic and Reconstructive Surgery, Tokyo Women's Medical University, Tokyo, Japan.
Resorbable implants are increasingly used in orbital wall fracture reconstruction because of their ability to provide temporary structural support without the long-term complications associated with permanent materials. However, the long-term effects of implant resorption on orbital morphology are unclear. This retrospective study evaluated volumetric changes over time following reconstruction using 2 types of resorbable plates: uncalcined hydroxyapatite/poly-L-lactic acid (u-HA/PLLA) and poly-L-lactic acid/polyglycolic acid (PLLA/PGA).
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
September 2025
Department of Ophthalmology, University of California, Los Angeles, Los Angeles, California, United States.
Purpose: Simulations suggest that displacement of rectus extraocular muscle pulleys in superior oblique (SO) palsy accounts for incomitant strabismus patterns even without postulating SO contractile weakness. We asked how rectus extraocular muscle pulleys reorient during head tilt in SO palsy.
Methods: In 13 subjects with unilateral SO palsy, supine magnetic resonance imaging (MRI) in 2-mm-thick quasi-coronal planes in target-controlled central gaze was repeated in both lateral decubitus positions equivalent to 90° head tilts.
Quant Imaging Med Surg
September 2025
Department of Radiology, Chongqing General Hospital, Chongqing University, Chongqing, China.
Background: Abdominal pain is a prevalent and debilitating manifestation of Crohn's disease (CD) that significantly impacts the lives of those affected. The neurological pathways responsible for abdominal pain in patients with CD remain unidentified. Therefore, the purpose of this study was to characterize the structural alterations in the brain and associated functional connectivity (FC) in patients with CD and abdominal pain.
View Article and Find Full Text PDF