Background/aims: There are few studies describing contemporary status of mechanical ventilation in Korea. We investigated changes in management and outcome of mechanical ventilation in Korea.
Methods: International, prospective observational cohort studies have been conducted every 6 years since 1998. Korean intensive care units (ICUs) participated in 2010 and 2016 cohorts. We compared 2016 and 2010 Korean data.
Results: Two hundred and twenty-six patients from 18 ICUs and 275 patients from 12 ICUs enrolled in 2016 and 2010, respectively. In 2016 compared to 2010, use of non-invasive ventilation outside ICU increased (10.2% vs. 2.5%, p = 0.001). Pressure-control ventilation was the most common mode in both groups. Initial tidal volume (7.1 mL/kg vs. 7.4 mL/kg, p = 0.372) and positive end-expiratory pressure (6 cmH2O vs. 6 cmH2O, p = 0.141) were similar, but peak pressure (22 cmH2O vs. 24 cmH2O, p = 0.011) was lower in 2016. More patients received sedatives (70.7% vs. 57.0%, p = 0.002) and analgesics (86.5% vs. 51.1%, p < 0.001) in 2016. The awakening (48.4% vs. 31.0%, p = 0.002) was more frequently attempted in 2016. The accidental extubation rate decreased to one tenth of what it was in 2010 (1.1% vs. 10.2%, p < 0.001). The ICU mortality did not change (31.4% 35.6%, p = 0.343) but ICU length of stay showed a decreasing trend (9 days vs. 10 days, p = 0.054) in 2016.
Conclusion: There were temporal changes in care of patients on mechanical ventilation including better control of pain and agitation, and active attempt of awakening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9082445 | PMC |
http://dx.doi.org/10.3904/kjim.2020.285 | DOI Listing |
J Hazard Mater
September 2025
Architectural Engineering Department, Pennsylvania State University, University Park, PA, USA. Electronic address:
Far-UVC systems and air cleaners are effective strategies for controlling airborne pathogen transmission, particularly in densely occupied spaces with insufficient ventilation, such as school classrooms. This study evaluates the disinfection performance and ozone (O) formation of different far-UVC systems and air cleaners in a standard-sized classroom using computational fluid dynamics (CFD) simulation. Results show that ceiling-mounted far-UVC systems reduce airborne pathogen exposure by up to 30 % more than upper-room and wall-mounted configurations, based on intake fractions and room-average concentrations.
View Article and Find Full Text PDFJ Crit Care
September 2025
Universidade do Oeste de Santa Catarina, Campus de Joaçaba, Brazil; Hospital Universitário Santa Terezinha, Joaçaba, Brazil. Electronic address:
Background: Timely extubation is essential in ICU patients, yet traditional predictors such as the rapid shallow breathing index (RSBI) have limited accuracy. Diaphragm and lung ultrasound offer promising, non-invasive alternatives for assessing extubation readiness.
Methods: We conducted a prospective observational study nested within a randomized trial in a university ICU.
J Med Ultrason (2001)
September 2025
Department of Emergency Medicine, Faculty of Medicine, Kindai University, Osaka, Japan.
Purpose: This study aimed to investigate muscle atrophy in critically ill patients using ultrasonography. We compared the rectus femoris (a major muscle of the lower limbs) with the sternocleidomastoid (an accessory respiratory muscle).
Methods: Thirty-four patients hospitalized at the Critical Care Medical Center of Kindai University Hospital between January 2022 and March 2023 were enrolled.
J Neurointerv Surg
September 2025
Shanxi Key Laboratory of Brain Disease Control, Department of Neurology, Shanxi Provincial People's Hospital, Taiyuan, Shanxi, China
Background: This study aims to develop an interpretable machine learning model using SHapley Additive exPlanations (SHAP) to predict favorable outcomes based on clinical, imaging, and angiographic data.
Methods: This study analyzed data from 184 patients with acute basilar artery occlusion (BAO) who underwent endovascular treatment (EVT) and completed a 90-day follow-up at Shanxi Provincial People's Hospital. A total of 68 medical variables were collected to develop predictive models using three machine learning algorithms: logistic regression (LR), support vector machine (SVM), and Light Gradient Boosting Machine (LightGBM).
BMJ Open
September 2025
Department of Neonatal Health Nursing, School of Nursing, College of Medicine and Health Sciences, and Specialized Hospital, University of Gondar, Gondar, Ethiopia.
Objective: To assess the incidence of delirium and its predictors among adult patients admitted to the intensive care units of comprehensive specialised hospitals in the Amhara region of northwest Ethiopia from 18 October 2024 to 20 February 2025.
Design: A multicentre prospective observational study was conducted.
Setting: Four comprehensive specialised hospitals in the Amhara region of northwest Ethiopia, from 18 October 2024 to 20 February 2025.