Aims: Assess the minimal number of ECGI leads needed to obtain a good spatial resolution.
Methods: We enrolled 20 patients that underwent ablation of premature ventricular or atrial contractions using Carto and ECGI with AMYCARD. We evaluated the agreement regarding the site of origin of the arrhythmia between the ECGI and Carto, the area and diameter of the earliest activation site obtained with the ECGI (EASa and EASd). Based on previous studies with pacemapping, we considered a good spatial resolution of the ECGI when the EASd measured on the isopotential map was less than 18 mm. In presence of agreement the ECGI was reprocessed: a) with half the number of electrode bands (8 leads per electrode band) and b) with 6 electrode bands.
Results: The initial map was obtained with 23 (22-23) electrode bands per patient, corresponding to 143 (130-170) leads. Agreement rate was 85%, the median EASa and EASd were: 0.7 (0.5-1.3) cm and 9 (8-13) mm. With half the number of electrode bands including 73 (60-79) leads, agreement rate was 80%, the EASa and EASd were: 2.1 (1.5-6.2) cm and 16 (14 -28) mm. With only six electrode bands using 38 (30-42) leads, agreement rate was 55%, EASa and EASd were: 4.0 (3.3-5.0) cm and 23 (21-25) mm. The number of leads was a predictor of agreement with a good spatial resolution, OR (95% CI) of 1.138 (1.050-1.234), p = .002. According to the ROC curve, the minimal number of leads was 74 (AUC 0.981; 95% CI: 0.949-1.00, p < .0001).
Conclusion: Reducing the number of leads was associated with a lower agreement rate and a significant reduction of spatial resolution. However, the number of leads needed to achieve a good spatial resolution was less than the maximal available.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelectrocard.2020.07.004 | DOI Listing |
Ann Clin Transl Neurol
September 2025
Department of Neuroscience, Psychology, Drug Research and Child Health, University of Florence, Florence, Italy.
Background: Plasma p-tau181 has proven to be a promising diagnostic and prognostic tool in the earliest phases of Alzheimer's disease (AD). We aimed to evaluate the prognostic role of p-tau181 in predicting conversion to AD dementia and worsening in cognition in mild cognitive impairment (MCI) and subjective cognitive decline (SCD).
Methods: We consecutively enrolled 163 patients (50 SCD, 70 MCI, and 43 AD-demented (AD-d)), who underwent plasma p-tau181 analysis with the Simoa assay.
Med Phys
September 2025
Department of Biomedical Engineering, University of California at Davis, Davis, California, USA.
Background: High-resolution and high-sensitivity small-animal positron emission tomography (PET) scanners are essential non-invasive functional imaging tools in preclinical research. To develop small-animal PET scanners with uniform and high spatial resolution across the field-of-view, PET detectors capable of providing good depth-of-interaction (DOI) information are critical. Dual-ended readout detectors based on lutetium-yttrium oxyorthosilicate (LYSO) arrays with fine pitch represent a promising approach, wherein the choice of inter-crystal reflector significantly impacts the detector performance.
View Article and Find Full Text PDFIntegr Environ Assess Manag
September 2025
School of Public Health, Taipei Medical University, New Taipei City, 235040Taiwan.
Incorporating bioaccessibility into health risk assessments enhances the accuracy of exposure estimates for heavy metal (HM) pollution, supports targeted remediation, and informs public health and policy decisions, particularly for vulnerable populations. Because HM bioaccessibility depends on local soil and geographic characteristics, identifying its relationship with soil properties is crucial for assessing soil pollution potential. Although HM concentrations can be measured relatively easily, bioaccessibility requires complex laboratory procedures, limiting routine applications in regulatory contexts.
View Article and Find Full Text PDFMagn Reson Med
September 2025
Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
Purpose: To develop a method for abdominal simultaneous 3D water ( ) and ( ) mapping with isotropic resolution using a free-breathing Cartesian acquisition with spiral profile ordering (CASPR) at 3 T.
Methods: The proposed data acquisition combines a Look-Locker scheme with the modified BIR-4 adiabatic preparation pulse for simultaneous and mapping. CASPR is employed for efficient and flexible k-space sampling at isotropic resolution during free breathing.
Nat Mater
September 2025
Department of Physics, University of Colorado, Boulder, CO, USA.
Time crystals are unexpected states of matter that spontaneously break time-translation symmetry either in a discrete or continuous manner. However, spatially mesoscale space-time crystals that break both space and time symmetries have not been reported. Here we report a continuous space-time crystal in a nematic liquid crystal driven by ambient-power, constant-intensity unstructured light.
View Article and Find Full Text PDF