Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Portable miniaturised scanning mobility particle sizer (SMPS) instruments measuring atmospheric particles within the 10-241 nm size range were used to track particle number size distributions and concentrations during near-simultaneous pedestrian, bicycle, bus, car, tram and subway commuting journeys in Barcelona, Spain on 4th-6th July 2018. The majority of particles in this size range were <100 nm, with k-means cluster analysis identifying peaks at 15-22 nm, 30-40 nm, and 45-75 nm. Around 10-25% of the particles measured however were >100 nm (especially in the subway environment) and so lie outside the commonly defined range of "ultrafine" particles (UFP, or <100 nm particles). The study demonstrated in detail how personal exposure to quasi-UFP (QUFP, <241 nm), most of which present in the city streets are produced by road traffic, varies greatly depending on the transport mode and route chosen. Proximity to fresh traffic exhaust sources, such as in a car with open windows, on-road cycling, walking downwind of busy roads, or in a subway station contaminated by roadside air, enhances commuter exposure to particles <30 nm in size. In contrast, travelling inside air-conditioned bus or tram offers greater protection to the commuter from high concentrations of fresh exhaust. Ultrafine number size distributions in traffic-contaminated city air typically peak in the size range 30-70 nm, but they can be shifted to finer sizes not only by increased content of fresh proximal exhaust emissions but also by bursts of new particle formation (NPF) events in the city. One such afternoon photochemical nucleation NPF event was identified during our Barcelona study and recognised in different transport modes, including underground in the subway system. The integration of static urban background air monitoring station information with particle number concentration and size distribution data obtained from portable miniaturised SMPS instruments during commuting journeys opens new approaches to investigating city air quality by offering a level of detail not previously available.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envres.2020.109978DOI Listing

Publication Analysis

Top Keywords

miniaturised scanning
8
scanning mobility
8
mobility particle
8
size range
8
particle sizers
4
sizers observe
4
size
4
observe size
4
size distribution
4
distribution patterns
4

Similar Publications

In this study, we describe the synthesis and characterization of the mononuclear complexes [ )], [ ], and [ ], where = (2-((2-hydroxybenzylidene)-amino)-phenol). The structural analysis of these complexes was carried out utilizing mass spectrometry, H NMR, C NMR, P NMR, UV-visible, and FT-IR. All three complexes were investigated as corrosion inhibitors for mild steel in 1 M HCl.

View Article and Find Full Text PDF

All-In-One Iontronic Sensing Aligner for High-Precision 3D Orthodontic Force Monitoring.

Adv Sci (Weinh)

September 2025

Department of Orthodontics, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Stomatology, NMPA Key

Clear aligners offer aesthetic and comfort advantages in orthodontics, yet their ability to deliver effective forces relies heavily on empirical judgment or large-scale optical scanning, lacking real-time quantitative evaluation. Integrating pressure sensors into aligners is a promising solution, but challenges in miniaturization, multi-dimensional sensing, measurement accuracy, and biocompatibility hinder clinical application. Here, an all-in-one Orthodontic Force Acquisition System (OFAS) is presented that enables real-time, 3D force monitoring using a cross-shaped iontronic sensing array and an origami-inspired, wireless battery-free readout circuit miniaturized for single-tooth placement.

View Article and Find Full Text PDF

Fast and accurate measurement of high aspect ratio MEMS trench array with optical lattice illumination.

Microsyst Nanoeng

August 2025

Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, China.

The high aspect ratio (HAR) micro-electro-mechanical system trench array is a key component for the miniaturization of micro sensors, actuators, and other advanced precision equipment, with broad application prospects in defense, security, aerospace, energy, and other fields. Therefore, accurate and efficient measurement of the aspect ratio of microstructures will become a crucial method for monitoring and ensuring the reliability and stability of the device fabrication process. This paper presents a novel method that combines the lattice light field generated by a micro-axicon array with microscopic imaging technology to accurately measure the width and depth of HAR micro-trench structures.

View Article and Find Full Text PDF

Disposable Printed Electrode Made with Chinese Shellac and Carbon Black for Melatonin Detection.

ACS Meas Sci Au

August 2025

Laboratory of Sensors, Nanomedicine, and Nanostructured Materials, Universidade Federal de São Carlos, Araras, São Paulo 13604-900, Brasil.

Screen-printed electrodes (SPEs) are an innovative technology in electrochemical sensors, offering advantages such as easy fabrication, large-scale production, low cost, and potential for miniaturization. These electrodes can be disposable and customized for various applications. Due to these advantages, SPEs are gaining attention in fields such as medicine and pharmacy.

View Article and Find Full Text PDF

Electrothermal micromirrors are suitable for miniaturization of confocal laser endomicroscopic (CLE) probes for in vivo imaging of internal organs due to their large linear scan range at low actuation voltages, but high-speed imaging requires resonant scanning under which those electrothermal micromirrors exhibit strong cross-axis coupling that leads to serious image reconstruction distortions. This paper presents a custom-built CLE probe that utilizes a two-axis asymmetric electrothermal MEMS mirror to achieve distortion-free in vivo imaging. The MEMS mirror with a size of 2mm × 2 mm is integrated into the CLE probe with a diameter of 8.

View Article and Find Full Text PDF