98%
921
2 minutes
20
Beak atrophy and dwarfism syndrome (BADS) is commonly caused by co-infection with duck circovirus (DuCV) and novel goose parvovirus (NGPV). Therefore, concurrent detection of both viruses is important for monitoring and limiting BADS, although such a diagnostic test has not been reported. In this study, we developed a duplex, SYBR Green I-based real-time polymerase chain reaction (PCR) assay to enable the simultaneous detection of DuCV and NGPV. The assay readily distinguished between the two viruses, based on their different melting temperatures (Tm), where the Tm for DuCV was 80 °C and that for NGPV was 84.5 °C. Other non-target duck viruses that were tested did not show melting peaks. The detection limit of the duplex assay was 10 copies/μL for both viruses. This method exhibited high repeatability and reproducibility, and both the inter-assay and intra-assay variation coefficients were <1.6%. Thirty-one fecal samples were collected for clinical testing using real-time PCR analysis, and the results were confirmed using sequencing. The rate of co-infection was 6.5%, which was consistent with the sequencing results. This duplex real-time PCR assay offers advantages over other tests, such as rapid, sensitive, specific, and reliable detection of both viruses in a single sample, which enables the quantitative detection of DuCV and NGPV in clinical samples. Using this test may be instrumental in reducing the incidence of BADS and the associated economic losses in the duck and goose industries.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7426261 | PMC |
http://dx.doi.org/10.1016/j.mcp.2020.101648 | DOI Listing |
Biomed Chromatogr
October 2025
Department of Pharmaceutical Analysis, Pharmacy School, Shenyang Pharmaceutical University, Shenyang, China.
A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.
View Article and Find Full Text PDFJ Mass Spectrom
October 2025
Graduate Program in Health Sciences, Federal University of Health Sciences of Porto Alegre (UFCSPA), Porto Alegre, Rio Grande do Sul, Brazil.
The laboratory analysis of new psychoactive substances and related drugs is crucial for accurate clinical and forensic diagnosis of poisonings. Given this, a new LC-MS/MS method for analyzing hallucinogens, synthetic cathinones, and synthetic cannabinoids in urine was developed. Urine samples were extracted using a liquid-liquid extraction protocol optimized via a multivariate experimental design.
View Article and Find Full Text PDFAnal Bioanal Chem
September 2025
GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Life Science and Technology, Jinan University, Guangzhou, 510632, China.
Illicit drug abuse poses a significant global threat to public health and social security, highlighting the urgent need for rapid, sensitive, and versatile detection technologies. To address the limitations of traditional chromatographic techniques-such as high costs and slow response times-and the drawbacks of conventional immunochromatographic sensors (ICS), including low sensitivity and non-intuitive signal outputs, a fluorescence-quenching ICS (FQICS) was developed. This sensor leverages fluorescence resonance energy transfer (FRET) between aggregation-induced emission fluorescent microspheres (AIEFMs) and gold nanoparticles (AuNPs).
View Article and Find Full Text PDFLight Sci Appl
September 2025
State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Camouflage technology has garnered increasing attention for various applications. With the continuous advancement of detection technologies and the increasing variability of camouflage scenarios, the demand for multispectral dynamic camouflage has been steadily growing. In this work, we present a multispectral dynamic regulator based on phase-changing material vanadium dioxide (VO) that can be dynamically and functional-independently regulated for reflective color and thermal radiation.
View Article and Find Full Text PDFSci Justice
September 2025
School of Life Sciences, University of KwaZulu-Natal, Private Bag X54001, Westville, Durban 4000, South Africa. Electronic address:
A compound marker integrates two or more genetic markers into a single assay. The application of compound markers enhances the predictive accuracy of genetic testing by leveraging the strengths of different genetic variations while mitigating the limitations of individual markers. Compound markers include SNP-SNPs, SNP-STRs, DIP-SNPs, DIP-STRs, Multi-In/Dels, CpG-SNPs, CpG-STRs/CpG-In/Del, and Methylation-Microhaplotypes.
View Article and Find Full Text PDF