Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Unstable fractures of the pelvis remain the predominant cause of severe hemorrhage, shock and early death in severely injured patients. The use of pelvic binders has become increasingly popular, particularly in the preclinical setting. There is currently insufficient evidence available about the stability of the pelvic binder versus supraacetabular fixation using 1 or 2 Schanz screws. We aimed to analyze the stability of the pelvic binder and supraacetabular fixateurs using either 1 or 2 Schanz screws in a cadaver model of an induced pelvic B-type fracture.

Materials And Methods: The study was undertaken in 7 human fresh-frozen cadaveric pelvises with induced AO-type B fractures. Three stabilization techniques were compared: T-POD (pelvic bandage), supraacetabular external fixator with 1 pin on each side and external fixator with 2 pins on each side. Stability and stiffness were analyzed in a biomechanical testing machine using a 5-step protocol with static and dynamic loading, dislocation data were retrieved by ultrasound sensors at the fracture sites.

Results: No significant differences in fracture fragment displacement were detected when using either the T-POD, a 1-pin external fixator or a 2-pin external fixator (P > 0.05). The average difference in displacement between the three methods was < 1 mm.

Conclusions: Pelvic binders are suitable for reduction of pelvic B-type fractures. They provide stability comparable to that of supraacetabular fixators, independently of whether 1 or 2 Schanz screws per side are used. Pelvic binders provide sufficient biomechanical stability for transferring patients without the need to first replace them with surgically applied external fixators. However, soft tissue irritation has to be taken into consideration and prolonged wear should be avoided.

Level Of Evidence: Level III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7368791PMC
http://dx.doi.org/10.1186/s40001-020-00427-0DOI Listing

Publication Analysis

Top Keywords

external fixator
16
schanz screws
12
supraacetabular fixation
8
fixation schanz
8
stability pelvic
8
pelvic binder
8
pelvic
6
t-pod stable
4
supraacetabular
4
stable supraacetabular
4

Similar Publications

BACKGROUND Periprosthetic tibial fractures following total knee arthroplasty (TKA) are increasingly encountered in very elderly patients, where multiple comorbidities and osteoporosis compromise early mobilization and elevate the risk of complications. Maintaining pre-injury activities of daily living (ADL) while ensuring safe surgical management is challenging. We present a case of a 95-year-old woman with a periprosthetic tibial shaft fracture managed with open reduction, additional plate fixation, and Ilizarov external fixation, enabling immediate postoperative weight-bearing.

View Article and Find Full Text PDF

BACKGROUND The treatment of nonunion with deformity and shortening remains a significant challenge in orthopedic surgery. The chipping and lengthening technique is used for bone reconstruction and new bone formation, without the need for bone grafting. However, inadequate bone regeneration can require additional treatment.

View Article and Find Full Text PDF

Objective: To evaluate the feasibility and accuracy of customized 3-D-printed casts, created using virtual surgical planning, to guide wire placement for external skeletal fixation in the canine radius.

Methods: This experimental cadaver study used normal forelimbs from medium-sized canine cadavers (19 to 23 kg). Computed tomography scans were performed to generate 3-D bone and soft tissue models.

View Article and Find Full Text PDF

Purpose: to evaluate the effect of a novel controlled dynamization device attached to external circular fixators on bone healing of tibial fractures.

Methods: this double-blinded randomized clinical trial evaluated 43 patients over 18 years of age with complex tibial pathologies who were treated without (control) or with a 3D-printed controlled dynamization device attached to external fixators. The devices were installed 60 days after fracture fixation surgery and used for 30 days.

View Article and Find Full Text PDF

Background: Low- and middle-income countries (LMICs) are disproportionately affected by trauma, resulting in >5 million deaths annually. An essential treatment for musculoskeletal trauma is external fixation. However, in LMICs, current external fixator assemblies are unaffordable, costing patients upward of $5,000 (USD), leaving LMICs to rely on donations that fail to meet the needs of the patient population.

View Article and Find Full Text PDF