Background: Complicated acetabular fractures comprise the most challenging field for orthopedists. The purpose of this study was to develop three-dimensional printed patient-specific (3DPPS) Ti-6Al-4 V plates to treat complicated acetabular fractures involving quadrilateral plate (QLP) disruption and to evaluate their efficacy.
Methods: Fifty patients with acetabular fractures involving QLP disruption were selected between January 2016 and June 2017. Patients were divided into a control group (Group A, 35 patients) and an experimental group (Group B, 15 patients), and were treated by the conventional method of shaping reconstruction plates or with 3DPPS Ti-6AL-4 V plates, respectively. The efficacy of Ti-6AL-4 V plates was evaluated by blood loss, operative time, reduction quality, postoperative residual displacement, and complications.
Results: The operative time and blood loss in Group B were reduced compared to Group A, and the difference was statistically significant (P < 0.05). There was no significant difference in reduction quality between the two groups (P > 0.05). Reduction quality in Group B was anatomic in 10 (66.7%), satisfactory in four (26.7%), and poor in one (6.7%). In Group A, they were anatomic in 18 (51.4%), satisfactory in 13 (37.1%), and poor in four (11.4%). Residual displacement in Group B was less than that in Group A, and the difference was statistically significant (P < 0.05). In Group B, one case exhibited loosening of the pubic screw postoperatively. In Group A, there was one case of wound infection, one of deep vein thrombosis (DVT) in the ipsilateral lower limb, one case of traumatic arthritis and two obturator nerve injuries.
Conclusions: The 3DPPS Ti-6AL-4 V plate is a feasible, accurate and effective implant for acetabular fracture treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7350601 | PMC |
http://dx.doi.org/10.1186/s12891-020-03370-7 | DOI Listing |
Vet Surg
September 2025
Clinic for Small Animals, University of Veterinary Medicine Hannover, Hannover, Germany.
Objective: To describe and compare arthroscopy-assisted (AA) with fluoroscopy-assisted (FA) minimally invasive plate osteosynthesis (MIPO) for simple transverse acetabular fractures.
Study Design: Ex vivo cadaveric study.
Sample Population: A total of 10 canine cadavers (>20 kg) without coxofemoral joint disease.
J Orthop Sci
September 2025
Department of Orthopaedics, All India Institute of Medical Sciences, Jodhpur, India.
Background: The Stoppa approach was modified to manage fractures of the anterior column as an alternative to the ilioinguinal approach to reduce complications. A debate persists regarding the superiority of one approach over the other. Therefore, in the present study we performed a randomized controlled trial (RCT) to investigate the following hypotheses: (1) Whether the modified Stoppa approach leads to reduced blood loss, (2) Whether the functional and radiological outcomes with the modified Stoppa approach are superior to those with the ilioinguinal approach, and (3) Whether the complication rates differ between the two approaches.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
September 2025
CHU de Grenoble-Alpes, Université de Grenoble-Alpes, Laboratoire TIMC-IMAG, Unité de Chirurgie Orthopédique et Traumatologique, CNRS UMR 5525, Boulevard de la Chantourne, 38700 La Tronche, France.
Percutaneous pelvic screwing (PPS) enables fixation of traumatic or atraumatic fractures with little or no displacement, or displaced but reduced fractures, and preventive fixation of primary or secondary tumoral lesions. It is a relatively recent technique, and indications are evolving with progress in pre- and intra-operative imaging. Morbidity is lower than with open surgery.
View Article and Find Full Text PDFEFORT Open Rev
September 2025
Department of Trauma Surgery, Amsterdam UMC, Amsterdam, The Netherlands.
Purpose: While the incidence of acetabular fractures keeps rising among our older patient population, age-specific rehabilitation guidelines are lacking. Post-surgery weight-bearing is often restricted for 8-12 weeks to avoid secondary fixation failure. However, non- or restricted weight-bearing commonly results in atrophy, and older patients are at additional risk of long-term mobility and functionality loss.
View Article and Find Full Text PDFHip Pelvis
September 2025
Department of Orthopaedics, SMS Medical College, Jaipur, India.
Purpose: Complex acetabular fractures involving both columns often require two approaches, one anterior and other posterior, for adequate reduction and fixation. Treatment of such fractures using modified Stoppa approach (MSA) either alone or in combination with lateral window of the ilio-inguinal approach has been reported. Whether this line of management is appropriate or not is a matter of further investigation.
View Article and Find Full Text PDF