98%
921
2 minutes
20
We firstly demonstrated a tunable 2.1 µm pumped mid-infrared type-II phase-matching (BGSe) optical parametric oscillator (OPO). A signal tuning range of 3.82-3.99 µm was achieved. With a signal light produced by the BGSe OPO serving as seed, the (ZGP) optical parametric amplifier (OPA) was first introduced. A 4.35 W mid-infrared laser was obtained in the novel type-II BGSe OPO with a ZGP OPA system, which was pumped by a 24 W 1 kHz -switched Ho:YAG laser. The beam quality factor of the whole system is ∼2.3, which is over a 50% promotion on the previous results of single BGSe OPO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.398588 | DOI Listing |
Cereb Cortex
August 2025
Translational Neuromodeling Unit (TNU), Institute for Biomedical Engineering, University of Zurich & ETH Zurich, Zurich, Switzerland.
Statistical Parametric Mapping (SPM) is a statistical framework and open source software package for neuroimaging data analysis. Originally created by Karl Friston in the early 1990s, it has been used by a vast number of scientific studies over the last three decades. SPM has not only revolutionized the analysis of neuroimaging data but also catalyzed the development of cognitive neuroscience.
View Article and Find Full Text PDFIEEE Trans Pattern Anal Mach Intell
September 2025
Human beings have the ability to continuously analyze a video and immediately extract the motion components. We want to adopt this paradigm to provide a coherent and stable motion segmentation over the video sequence. In this perspective, we propose a novel long-term spatio-temporal model operating in a totally unsupervised way.
View Article and Find Full Text PDFJ Refract Surg
September 2025
From National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
Purpose: To use parametric numerical simulation to characterize and compare the differences in corneal biomechanical responses to laser in situ keratomileusis (LASIK) and keratorefractive lenticule extraction (KLEx) under various surgical settings.
Methods: The Finite Element Model was used in a parametric study to evaluate corneal biomechanical responses to LASIK and KLEx, considering variations in preoperative corneal thickness, corneal flap/cap thickness and diameter, refractive correction, and optical zone diameter. Surgery-induced stress, displacement, and interface contact pressure were compared between LASIK and KLEx using the Wilcoxon signed-rank test.
J Adv Prosthodont
August 2025
Department of Prosthodontics, Istanbul University, Istanbul, Turkey.
Purpose: This study investigated how different data collection methods affect final restoration design and dynamic occlusal morphology.
Materials And Methods: Digital systems allow intraoral recording of functional occlusal paths through the digitally recorded functionally generated pathway (DRFGP) technique, using intraoral scanners and optical jaw tracking. Two substudies were conducted.
ACS Omega
September 2025
Laboratório de Modelagem Molecular Aplicada e Simulação (LaMMAS), Universidade Estadual de Goiás, Anápolis, GO 75001-970, Brazil.
In this work, we report a theoretical investigation of the third-order nonlinear optical properties of the metronidazolium-picrate salt. The effects of the crystal environment are accounted for by the Iterative Charge Embedding approach, and the electronic calculations are carried out at the DFT (CAM-B3LYP/6-311++G-(d,p)) level. Furthermore, we use the results to parametrize a cavity Quantum Electrodynamics model for a quantum memory based on the Off-Resonant Cascaded Absorption protocol.
View Article and Find Full Text PDF