Objective: To understand the status of pre-procedural safety practices in radiological examinations at radiology residency training institutions in various Asian regions.

Methods: A questionnaire based on the Joint Commission International Accreditation Standards was electronically sent to 3 institutions each in 10 geographical regions across 9 Asian countries. Questions addressing 45 practices were divided into 3 categories. A five-tier scale with numerical scores was used to evaluate safety practices in each institution. Responses obtained from three institutions in the United States were used to validate the execution rate of each surveyed safety practice.

Results: The institutional response rate was 70.0% (7 Asian regions, 21 institutions). 44 practices (all those surveyed except for the application of wrist tags for identifying patients with fall risks) were validated using the US participants. Overall, the Asian participants reached a consensus on 89% of the safety practices. Comparatively, most Asian participants did not routinely perform three pre-procedural practices in the examination appropriateness topic.

Conclusion: Based on the responses from 21 participating Asian institutions, most routinely perform standard practices during radiological examinations except when it comes to examination appropriateness. This study can provide direction for safety policymakers scrutinizing and improving regional standards of care.

Advances In Knowledge: This is the first multicenter survey study to elucidate pre-procedural safety practices in radiological examinations in seven Asian regions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7465868PMC
http://dx.doi.org/10.1259/bjr.20200082DOI Listing

Publication Analysis

Top Keywords

safety practices
20
practices radiological
16
radiological examinations
16
pre-procedural safety
12
asian regions
12
practices
9
asian
8
asian participants
8
routinely perform
8
examination appropriateness
8

Similar Publications

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

The global surge in the population of people 60 years and older, including that in China, challenges healthcare systems with rising age-related diseases. To address this demographic change, the Aging Biomarker Consortium (ABC) has launched the X-Age Project to develop a comprehensive aging evaluation system tailored to the Chinese population. Our goal is to identify robust biomarkers and construct composite aging clocks that capture biological age, defined as an individual's physiological and molecular state, across diverse Chinese cohorts.

View Article and Find Full Text PDF

Background: Blepharitis, meibomian gland dysfunction (MGD), and chalazia are common disorders impacting quality of life. This population-based, pharmacovigilance study aims to identify systemic drugs disproportionately linked to these disorders.

Methods: Data from the Food and Drug Administration Adverse Event Reporting System (FAERS) were analysed (Q4 2003 to Q2 2024).

View Article and Find Full Text PDF

Antitumor Effects of Doxorubicin-Loaded Cellulose Nanoparticles in the Rabbit VX2 Liver Tumor Model.

Cardiovasc Intervent Radiol

September 2025

Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82, Gumi-ro 173Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea.

Purpose: To evaluate the preclinical efficacy and safety of transarterial chemoembolization (TACE) using doxorubicin-loaded biocompatible cellulose nanoparticles in a rabbit VX2 liver tumor model.

Materials And Methods: Following institutional animal care committee approval, 23 rabbits with VX2 liver tumors were randomized into three groups: Group A (n = 9) received doxorubicin-loaded cellulose nanoparticles with ethiodized oil; Group B (n = 9) received doxorubicin with ethiodized oil; and Group C (n = 5) served as untreated controls. Tumor size was monitored via ultrasound for 4 weeks, and serum liver enzymes (aspartate transaminase and alanine transaminase) were measured on days 1, 3, and 7 to assess hepatotoxicity.

View Article and Find Full Text PDF

Objective: This research aimed at evaluating the effectiveness and safety of nitazoxanide and escitalopram as adjuvant therapies in patients with rheumatoid arthritis (RA).

Methods: In this randomized controlled parallel study, 90 patients with active RA were randomized into three groups; group 1 (control group; n = 30) which received traditional therapy, group 2 (Nitazoxanide group; n = 30) which received traditional therapy plus 1 gm/day oral nitazoxanide, and group 3 (Escitalopram group; n = 30) which received traditional therapy plus 10 mg/day oral escitalopram for three months. At baseline and 3 months after treatment, clinical and functional assessments were done through the 28-joint count disease activity score using C-reactive protein (DAS28-CRP), the health assessment questionnaire-disability index (HAQ-DI), and the patient's global assessment (PGA).

View Article and Find Full Text PDF