Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This paper presents an experimental and numerical analysis using the finite element method (FEM) of the bending of honeycomb-core panel. Segments of honeycomb paperboard of several thicknesses were subjected to four-point flexure tests to determine their bending stiffness and maximum load. Several mechanical properties of orthotropic materials were taken into account to account for the experimental results. The numerical analysis of the damage prediction was conducted by using well-known failure criteria such as maximum stress, maximum strain and Tsai-Wu. The present study revealed how to model the honeycomb panel to obtain curves close to experimental ones. This approach can be useful for modelling more complex structures made of honeycomb paperboard. Moreover, thanks to the use of variously shaped cells in numerical models, i.e., the shape of a regular hexagon and models with a real shape of the core cell, results of the calculation were comparable with the results of the measurements. It turned out that the increase of maximum loads and rise in stiffness for studied samples were almost either linearly proportional or quadratically proportional as a function of the panel thickness, respectively. On the basis of failure criteria, slightly lower maximum loads were attained in a comparison to empiric maximum loads.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7321572PMC
http://dx.doi.org/10.3390/ma13112601DOI Listing

Publication Analysis

Top Keywords

maximum loads
12
experimental numerical
8
numerical analysis
8
honeycomb paperboard
8
failure criteria
8
maximum
6
flexural damage
4
honeycomb
4
damage honeycomb
4
honeycomb paperboard-a
4

Similar Publications

Multi-arm rock drilling robots frequently encounter challenges in extreme environments, such as tunnels, where they are subjected to high-frequency impact loads, multi-degree-of-freedom motion coupling, and large-range motion control vibrations. First, we propose a collision-free path planning method that combines an improved genetic algorithm (IGA) and an improved artificial potential field method. This method is based on the kinematic model of the rock drilling robot.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of die spacer thickness on the fit and load to failure of cantilever resin-bonded fixed dental prostheses (RBFDPs).

Methods: Two identical maxillary RBFDPs with a retainer on the canine were designed to replace a lateral incisor. One design involved a closely fitting retainer with no die spacer (NDS), and the other included an 80-µm die spacer (DS).

View Article and Find Full Text PDF

Spatially and temporally controlled drug delivery is an important field to address the limitations of conventional pharmaceutical administration. While many effective controlled drug delivery systems exist, the repertoire of systems that additionally present a beneficial mechanical environment to cells remains scarce. To address this, a comprehensive release study of fluorescein as a model drug, and the corticosteroid dexamethasone, from poly(-isopropylacrylamide)/polypyrrole (pNIPAM/PPy) conducting polymer hydrogels is presented within this study.

View Article and Find Full Text PDF

This study aimed to create multifunctional nanoparticles (NPs), specifically AS1411@MPDA-Len-Cy5.5 (AMLC), for the purpose of developing effective strategies for treating hepatocellular carcinoma (HCC) through targeted therapy and photothermal therapy (PTT). The study involved synthesizing mesoporous polydopamine (MPDA)-NPs, loading lenvatinib (Len) and Cy5.

View Article and Find Full Text PDF

Objective: Due to its inherent high instability, the selection of fixation strategies for unilateral Denis type II sacral fractures remains a controversial challenge in the field of traumatic orthopedics. This study focuses on unilateral Denis type II sacral fractures. By applying three different fixation methods, it aims to explore their biomechanical properties and provide a theoretical basis for optimizing clinical fixation protocols.

View Article and Find Full Text PDF