Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aims: We aimed to examine the long-term mechanical survivorship, describe the modes of all-cause failure, and identify risk factors for mechanical failure of all-polyethylene tibial components in endoprosthetic reconstruction.

Methods: This is a retrospective database review of consecutive endoprosthetic reconstructions performed for oncological indications between 1980 and 2019. Patients with all-polyethylene tibial components were isolated and analyzed for revision for mechanical failure. Outcomes included survival of the all-polyethylene tibial component, revision surgery categorized according to the Henderson Failure Mode Classification, and complications and functional outcome, as assessed by the Musculoskeletal Tumor Society (MSTS) score at the final follow-up.

Results: A total of 278 patients were identified with 289 all-polyethylene tibial components. Mechanical survival was 98.4%, 91.1%, and 85.2% at five, ten and 15 years, respectively. A total of 15 mechanical failures were identified at the final follow-up. Of the 13 all-polyethylene tibial components used for revision of a previous tibial component, five (38.5%) failed mechanically. Younger patients (< 18 years vs > 18 years; p = 0.005) and those used as revision components (p < 0.001) had significantly increased rates of failure. Multivariate logistic regression modelling showed revision status to be a positive risk factor for failure (odds ratio (OR) 19.498, 95% confidence interval (CI) 4.598 to 82.676) and increasing age was a negative risk factor for failure (OR 0.927, 95% CI 0.872 to 0.987). Age-stratified risk analysis showed that age > 24 years was no longer a statistically significant risk factor for failure. The final mean MSTS score for all patients was 89% (8.5% to 100.0%).

Conclusion: The long-term mechanical survivorship of all-polyethylene tibial components when used for tumour endoprostheses was excellent. Tumour surgeons should consider using these components for their durability and the secondary benefits of reduced cost and ease of removal and revision. However, caution should be taken when using all-polyethylene tibial components in the revision setting as a significantly higher rate of mechanical failure was seen in this group of patients. Cite this article: 2020;102-B(2):170-176.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.102B2.BJJ-2019-0535.R1DOI Listing

Publication Analysis

Top Keywords

all-polyethylene tibial
32
tibial components
28
mechanical failure
12
risk factor
12
factor failure
12
tibial
9
components
9
failure
9
all-polyethylene
8
follow-up all-polyethylene
8

Similar Publications

Background: Two tibial component designs are mainly used in fixed-bearing unicompartmental knee arthroplasty (UKA): metal-backed (MtB) and all-polyethylene (AP). While AP components allow for increased polyethylene thickness with minimal bone resection, MtB implants offer modularity for isolated bearing exchange and potentially superior stress distribution. However, controversy remains regarding their respective revision rates and patient-reported outcome measures (PROMs).

View Article and Find Full Text PDF

Purpose: This study aims to analyse the short- and long-term survival rate of an all-polyethylene tibia UKR, and the relationship with implant thickness and patient demographics including sex, age, ASA, and BMI.

Methods: This was a single centre, retrospective, observational study of 388 consecutive medial fixed bearing all-polyethylene tibia UKRs done by a single surgeon between 2007 and 2019. We analysed the survival rate at 2, 5, 7, and 10 years and any relationship with sex, BMI, ASA, and implant thickness.

View Article and Find Full Text PDF

Purpose: The comparative survivorship of all-polyethylene (AP) versus metal-backed (MB) tibial components in unicompartmental knee arthroplasty (UKA) remains unclear, as previous studies mainly used relative risk without comprehensive time-to-event analysis.

Methods: Following PRISMA guidelines, a systematic review and meta-analysis were performed. Databases (PubMed, Scopus, Embase and Web of Science) were searched without restrictions.

View Article and Find Full Text PDF

Experimental wear simulation of a PEEK-OPTIMA™ polymer-on-UHMWPE total knee replacement has shown equivalent UHMWPE wear to conventional knee replacement materials (cobalt chrome-on-UHMWPE) when tested in a clean environment. The aim of this study was to experimentally investigate the wear of this all-polymer total knee replacement under third body wear conditions. Three PEEK-OPTIMA™ and three cobalt chrome femoral components articulating against all-polyethylene tibial components were tested in a knee simulator.

View Article and Find Full Text PDF

Background: The two-stage surgical protocols used for the treatment of periprosthetic joint infection following total knee arthroplasty are associated with marked patient morbidity. As such, alternatives, such as durable "1.5-stage" spacer constructs, have gained popularity.

View Article and Find Full Text PDF