98%
921
2 minutes
20
Assessment of health effects from low-dose radiation exposures in patients undergoing diagnostic imaging is an active area of research. High-quality dosimetry information pertaining to these medical exposures is generally not readily available to clinicians or epidemiologists studying radiation-related health risks. The purpose of this study was to provide methods for organ dose estimation in pediatric patients undergoing four common diagnostic fluoroscopy procedures: the upper gastrointestinal (UGI) series, the lower gastrointestinal (LGI) series, the voiding cystourethrogram (VCUG) and the modified barium swallow (MBS). Abstracted X-ray film data and physician interviews were combined to generate procedure outlines detailing X-ray beam projections, imaged anatomy, length of X-ray exposure, and presence and amount of contrast within imaged anatomy. Monte Carlo radiation transport simulations were completed for each of the four diagnostic fluoroscopy procedures across the 162-member (87 males and 75 females) University of Florida/National Cancer Institute pediatric phantom library, which covers variations in both subject height and weight. Absorbed doses to 28 organs, including the active marrow and bone endosteum, were assigned for all 162 phantoms by procedure. Additionally, we provide dose coefficients (DCs) in a series of supplementary tables. The DCs give organ doses normalized to procedure-specific dose metrics, including: air kerma-area product (µGy/mGy · cm), air kerma at the reference point (µGy/µGy), number of spot films (SF) (µGy/number of SFs) and total fluoroscopy time (µGy/s). Organs accumulating the highest absorbed doses per procedure were as follows: kidneys between 0.9-25.4 mGy, 1.1-16.6 mGy and 1.1-9.7 mGy for the UGI, LGI and VCUG procedures, respectively, and salivary glands between 0.2-3.7 mGy for the MBS procedure. Average values of detriment-weighted dose, a phantom-specific surrogate for the effective dose based on ICRP Publication 103 tissue-weighting factors, were 0.98 mSv, 1.16 mSv, 0.83 mSv and 0.15 mSv for the UGI, LGI, VCUG and MBS procedures, respectively. Scalable database of organ dose coefficients by patient sex, height and weight, and by procedure exposure time, reference point air kerma, kerma-area product or number of spot films, allows clinicians and researchers to compute organ absorbed doses based on their institution-specific and patient-specific dose metrics. In addition to informing on patient dosimetry, this work has the potential to facilitate exposure assessments in epidemiological studies designed to investigate radiation-related risks.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1667/RR15445.1 | DOI Listing |
Arch Orthop Trauma Surg
September 2025
Department of Orthopedic Surgery, Aybars Kıvrak Orthopedics Clinic, Adana, Turkey.
Purpose: This study aimed to compare the clinical outcomes and cost-effectiveness of two widely used intramedullary fixation systems-the Proximal Femoral Nail Antirotation (PFNA) and the Proximal Femoral Nail with Talon Locking System (PFN-TLS)-in the treatment of intertrochanteric femur fractures (ITFF).
Methods: A retrospective cohort study was conducted on 118 patients aged 65-90 years who underwent surgical treatment for ITFF using either PFNA (n = 53) or PFN-TLS (n = 65). All patients were followed for a minimum of 24 months.
Arch Orthop Trauma Surg
September 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Background: Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.
View Article and Find Full Text PDFComparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months.
View Article and Find Full Text PDFMedicine (Baltimore)
September 2025
Department of Orthopaedic Surgery, Kobe Red Cross Hospital, Hyogo, Japan.
This study aims to clarify the dynamic changes in the cervical lordotic angle (CLA) during normal swallowing using an automated motion analysis method. Physiological cervical lordosis is crucial for spinal alignment and musculoskeletal function. While previous studies have noted the relevance of cervical curvature in clinical contexts, its dynamic modulation during swallowing has not been well studied.
View Article and Find Full Text PDFJ Int Med Res
September 2025
Department of Orthopedics and Traumatology, Health Sciences University Fatih Sultan Mehmet Training and Research Hospital, Turkey.
ObjectiveTo determine the effectiveness of bilateral decompression combined with a unilateral transforaminal lumbar interbody fusion approach in centralizing a lordotic cage and preventing contralateral radiculopathy by ensuring equal foraminal elevation.MethodsThis is a retrospective cohort study based on clinical records and radiological data. Eighty-seven patients diagnosed with lumbar spinal stenosis at L3-S1 levels underwent bilateral decompression and transforaminal lumbar interbody fusion between 2017 and 2022.
View Article and Find Full Text PDF