Publications by authors named "David Borrego"

International Commission on Radiological Protection (ICRP) Task Group 113 is developing reference values of organ and effective dose coefficients (DCs) for radiography, fluoroscopy, and computed tomography imaging exams. In support of these efforts, our focus is on pediatric diagnostic fluoroscopy. Contrast agents used during clinical examinations are an important consideration of the work undertaken by the Task Group.

View Article and Find Full Text PDF

Purpose: To summarize dose trends from 1980 to 2020 for 19,651 U.S. Radiologic Technologists who reported assisting with fluoroscopically guided interventional procedures (FGIPs), overall and by work history characteristics.

View Article and Find Full Text PDF

The process to arrive at the radiation protection practices of today to protect workers, patients, and the public, including sensitive populations, has been a long and deliberative one. This paper presents an overview of the US Environmental Protection Agency's (US EPA) responsibility in protecting human health and the environment from unnecessary exposure to radiation. The origins of this responsibility can be traced back to early efforts, a century ago, to protect workers from x rays and radium.

View Article and Find Full Text PDF

Background: Many high-dose groups demonstrate increased leukaemia risks, with risk greatest following childhood exposure; risks at low/moderate doses are less clear.

Methods: We conducted a pooled analysis of the major radiation-associated leukaemias (acute myeloid leukaemia (AML) with/without the inclusion of myelodysplastic syndrome (MDS), chronic myeloid leukaemia (CML), acute lymphoblastic leukaemia (ALL)) in ten childhood-exposed groups, including Japanese atomic bomb survivors, four therapeutically irradiated and five diagnostically exposed cohorts, a mixture of incidence and mortality data. Relative/absolute risk Poisson regression models were fitted.

View Article and Find Full Text PDF

Background: In ISCHEMIA-CKD, 777 patients with advanced chronic kidney disease and chronic coronary disease had similar all-cause mortality with either an initial invasive or conservative strategy (27.2% vs 27.8%, respectively).

View Article and Find Full Text PDF
Article Synopsis
  • Human immunodeficiency virus (HIV) reverse transcriptase has an associated enzyme (RNase H) that hasn’t been validated for antiviral treatment, making it a unique target for research.
  • Investigations on a compound called II-25 showed it inhibited RNase H but was ineffective as an antiviral due to its polarity and poor ability to penetrate cell membranes.
  • Researchers created several II-25 derivatives, and one, IA-6, was found to be highly effective in inhibiting RNase H, yet none demonstrated significant antiviral effects in cell cultures, although they displayed low toxicity levels, suggesting potential for future development.
View Article and Find Full Text PDF
Article Synopsis
  • * Although cardiovascular death rates were similar between the two approaches (2.6% for invasive vs 3.0% for conservative), non-cardiovascular deaths were higher in the invasive group (3.3% vs 2.1%).
  • * The study also reported fewer undetermined causes of death with invasive treatment, but a higher prevalence of cancer-related deaths; these findings need further investigation and must be viewed cautiously with respect to existing research.
View Article and Find Full Text PDF

Purpose: To describe the range of occupational badge dose readings and annualized dose records among physicians performing fluoroscopically guided interventional (FGI) procedures using job title information provided by the same 3 major medical institutions in 2009, 2012, and 2015.

Materials And Methods: The Radiation Safety Office of selected hospitals was contacted to request assistance with identifying physicians in a large commercial dosimetry database. All entries judged to be uninformative of occupational doses to FGI procedure staff were excluded.

View Article and Find Full Text PDF

Background Occupational doses to most medical radiation workers have declined substantially since the 1950s because of improvements in radiation protection practices. However, different patterns may have emerged for radiologic technologists working with nuclear medicine because of the higher per-procedure doses and increasing workloads. Purpose To summarize annual occupational doses during a 36-year period for a large cohort of U.

View Article and Find Full Text PDF

There is limited evidence that non-leukaemic lymphoid malignancies are radiogenic. As radiation-related cancer risks are generally higher after childhood exposure, we analysed pooled lymphoid neoplasm data in nine cohorts first exposed to external radiation aged <21 years using active bone marrow (ABM) and, where available, lymphoid system doses, and harmonised outcome classification. Relative and absolute risk models were fitted.

View Article and Find Full Text PDF

As part of ongoing efforts to assess lifespan disease mortality and incidence in 63,715 patients from the Canadian Fluoroscopy Cohort Study (CFCS) who were treated for tuberculosis between 1930 and 1969, we developed a new FLUoroscopy X-ray ORgan-specific dosimetry system (FLUXOR) to estimate radiation doses to various organs and tissues. Approximately 45% of patients received medical procedures accompanied by fluoroscopy, including artificial pneumothorax (air in pleural cavity to collapse of lungs), pneumoperitoneum (air in peritoneal cavity), aspiration of fluid from pleural cavity and gastrointestinal series. In addition, patients received chest radiographs for purposes of diagnosis and monitoring of disease status.

View Article and Find Full Text PDF
Article Synopsis
  • The HARMONIC project studies how radiation from medical procedures affects kids' health in the long run.
  • It involves about 100,000 young patients from several European countries who had heart exams using radiation before they turned 22.
  • The goal is to figure out the links between radiation exposure and cancer risks, to help doctors keep patients safer while still providing the care they need.
View Article and Find Full Text PDF

This paper describes a study to estimate absorbed doses to various organs from film-based chest radiographs and their uncertainties in the periods 1930 to 1948, 1949 to 1955, and 1956 to 1969. Estimated organ doses will be used in new analyses of risks of cancer and other diseases in tuberculosis patients in Canada who had chest fluoroscopic and radiographic examinations in those periods. In this paper, doses to lungs, female breast, active bone marrow, and heart from a single chest radiograph in adults and children of ages 1, 5, 10, and 15 y in the Canadian cohort and their uncertainties are estimated using (1) data on the tube voltage (kV), total filtration (mm Al), tube-current exposure-time product (mA s), and tube output (mR [mA s]) in each period; (2) assumptions about patient orientation, distance from the source to the skin of a patient, and film size; and (3) new calculations of sex- and age-specific organ dose conversion coefficients (organ doses per dose in air at skin entrance).

View Article and Find Full Text PDF
Article Synopsis
  • Medical staff performing fluoroscopically guided interventional (FGI) procedures are highly exposed to radiation, but there’s a lack of data on their radiation doses over time.
  • A study analyzed occupational badge dose data for over 250,000 medical workers from 2009 to 2015, excluding uninformative readings, and found that a significant portion of badge entries were deemed informative.
  • The results showed no significant change in radiation exposure levels over the years for workers using one or two badges, indicating a consistent radiation environment for those involved in FGI procedures.
View Article and Find Full Text PDF

Assessment of health effects from low-dose radiation exposures in patients undergoing diagnostic imaging is an active area of research. High-quality dosimetry information pertaining to these medical exposures is generally not readily available to clinicians or epidemiologists studying radiation-related health risks. The purpose of this study was to provide methods for organ dose estimation in pediatric patients undergoing four common diagnostic fluoroscopy procedures: the upper gastrointestinal (UGI) series, the lower gastrointestinal (LGI) series, the voiding cystourethrogram (VCUG) and the modified barium swallow (MBS).

View Article and Find Full Text PDF

This work provides dose coefficients necessary to reconstruct doses used in epidemiological studies of tuberculosis patients treated from the 1930s through the 1960s, who were exposed to diagnostic imaging while undergoing treatment. We made use of averaged imaging parameters from measurement data, physician interviews, and available literature of the Canadian Fluoroscopy Cohort Study and, on occasion, from a similar study of tuberculosis patients from Massachusetts, United States, treated between 1925 and 1954. We used computational phantoms of the human anatomy and Monte Carlo radiation transport methods to compute dose coefficients that relate dose in air, at a point 20 cm away from the source, to absorbed dose in 58 organs.

View Article and Find Full Text PDF

Of all the medical imaging modalities that utilize ionizing radiation, fluoroscopy proves to be the most difficult to assess values of patient organ dose owing to the dynamic and patient-specific nature of the irradiation geometry and its associated x-ray beam characteristics. With the introduction of the radiation dose structured report (RDSR) in the mid-2000s, however, computational tools have been developed to extract patient and procedure-specific data for each irradiation event of the study, and when coupled to a computational phantom of the patient, values of skin and internal organ dose may be assessed. Unfortunately, many legacy and even current diagnostic fluoroscopy units do not have RDSR reporting capabilities, thus limiting these dosimetry reporting advances.

View Article and Find Full Text PDF

Objectives: To assess radiation exposure-related work history and risk of cataract and cataract surgery among radiologic technologists assisting with fluoroscopically guided interventional procedures (FGIP).

Methods: This retrospective study included 35 751 radiologic technologists who reported being cataract-free at baseline (1994-1998) and completed a follow-up questionnaire (2013-2014). Frequencies of assisting with 21 types of FGIP and use of radiation protection equipment during five time periods (before 1970, 1970-1979, 1980-1989, 1990-1999, 2000-2009) were derived from an additional self-administered questionnaire in 2013-2014.

View Article and Find Full Text PDF

In epidemiological investigations of cancer risk from occupational exposure, it is important to obtain an organ-specific dose for each cohort member for accurate risk analysis. To date, dose conversion coefficients, which convert physical dose measurement to organ dose, are only available for individuals with reference body size, which can differentially bias the estimated organ dose depending on the body mass index of cohort members. In the current study, we calculated the organ dose coefficients applicable to adult males and females with various body weights by using the Monte Carlo radiation transport technique combined with a library of body size-dependent hybrid computational phantoms exposed in six idealised irradiation geometries.

View Article and Find Full Text PDF

It has long been known that relatively high-dose ionising radiation exposure (> 1 Gy) can induce cataract, but there has been no evidence that this occurs at low doses (< 100 mGy). To assess low-dose risk, participants from the US Radiologic Technologists Study, a large, prospective cohort, were followed from date of mailed questionnaire survey completed during 1994-1998 to the earliest of self-reported diagnosis of cataract/cataract surgery, cancer other than non-melanoma skin, or date of last survey (up to end 2014). Cox proportional hazards models with age as timescale were used, adjusted for a priori selected cataract risk factors (diabetes, body mass index, smoking history, race, sex, birth year, cumulative UVB radiant exposure).

View Article and Find Full Text PDF

Background: Substantial evidence links exposure to moderate or high doses of ionising radiation, particularly in childhood, with increased risk of leukaemia. The association of leukaemia with exposure to low-dose (<100 mSv) radiation is less certain, although this is the dose range most relevant to the general population. We aimed to estimate the risk of leukaemia associated with low-dose radiation exposure in childhood (age <21 years).

View Article and Find Full Text PDF
Article Synopsis
  • * Out of nearly 70,000 eligible subjects, the analysis found 1,631 cases of glaucoma and 1,331 cases of macular degeneration, with an estimated mean radiation dose of 0.058 Gy, considered low.
  • * The results indicated no significant increased risk for glaucoma or macular degeneration associated with low-dose radiation, but researchers suggest that further studies are needed to confirm these findings.
View Article and Find Full Text PDF

Purpose: To assess various computational phantom alignment techniques within Monte Carlo radiation transport models of pediatric fluoroscopically guided cardiac interventional studies.

Methods: Logfiles, including all procedure radiation and machine data, were extracted from a Toshiba infinix-I unit in the University of Florida Pediatric Catheterization Laboratory for a cohort of 10 patients. Two different alignment methods were then tested against a ground truth standard based upon identification of a unique anatomic reference point within images co-registered to specific irradiation events within each procedure.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to experimentally validate UF-RIPSA, a rapid in-clinic peak skin dose mapping algorithm developed at the University of Florida using optically stimulated luminescent dosimeters (OSLDs) and tissue-equivalent phantoms.

Methods: The OSLDs used in this study were InLight Nanodot dosimeters by Landauer, Inc. The OSLDs were exposed to nine different beam qualities while either free-in-air or on the surface of a tissue equivalent phantom.

View Article and Find Full Text PDF