Article Abstract

Purpose: Nyquist ghost artifacts in echo planar imaging (EPI) are originated from phase mismatch between the even and odd echoes. However, conventional correction methods using reference scans often produce erroneous results especially in high-field MRI due to the nonlinear and time-varying local magnetic field changes. Recently, it was shown that the problem of ghost correction can be reformulated as k-space interpolation problem that can be solved using structured low-rank Hankel matrix approaches. Another recent work showed that data driven Hankel matrix decomposition can be reformulated to exhibit similar structures as deep convolutional neural network. By synergistically combining these findings, we propose a k-space deep learning approach that immediately corrects the phase mismatch without a reference scan in both accelerated and non-accelerated EPI acquisitions.

Theory And Methods: To take advantage of the even and odd-phase directional redundancy, the k-space data are divided into 2 channels configured with even and odd phase encodings. The redundancies between coils are also exploited by stacking the multi-coil k-space data into additional input channels. Then, our k-space ghost correction network is trained to learn the interpolation kernel to estimate the missing virtual k-space data. For the accelerated EPI data, the same neural network is trained to directly estimate the interpolation kernels for missing k-space data from both ghost and subsampling.

Results: Reconstruction results using 3T and 7T in vivo data showed that the proposed method outperformed the image quality compared to the existing methods, and the computing time is much faster.

Conclusions: The proposed k-space deep learning for EPI ghost correction is highly robust and fast, and can be combined with acceleration, so that it can be used as a promising correction tool for high-field MRI without changing the current acquisition protocol.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.27896DOI Listing

Publication Analysis

Top Keywords

ghost correction
16
k-space data
16
k-space deep
12
deep learning
12
k-space
9
epi ghost
8
phase mismatch
8
high-field mri
8
hankel matrix
8
neural network
8

Similar Publications

Retinal vascular tree segmentation and enhancement has significant medical imaging benefits because, unlike any other human organ, the retina allows non-invasive observation of blood microcirculation, making it ideal for the detection of systemic diseases. Many traditional methods of segmentation and enhancement encounter issues with visual distortion, ghost artifacts, spatially inconsistent structures, and edge information preservation as a result of the diffusion of spatial intensities at the edges. This article introduces an Optimal Anisotropic Guided Filtering (OAGF) framework tailored for retinal fundus imaging, addressing both enhancement and segmentation needs in a unified approach.

View Article and Find Full Text PDF

Purpose: This work aims to develop a robust Nyquist ghost correction method for multishot echo-planar imaging (EPI). The method helps correct challenging Nyquist ghosts, particularly on scanners with high-performance gradients or ultra-high fields.

Methods: A method for multishot EPI ghost correction, called multishot dual-polarity GRAPPA (msDPG), is developed by extending the DPG concept to multishot readouts.

View Article and Find Full Text PDF

Purpose: To propose and develop an image processing-based methodology for detecting and correcting residual Nyquist ghost artifacts in echo planar imaging (EPI), specifically using non-diffusion-weighted (b=0s/mm) images acquired with four distinct phase-encoding directions (PEDs) in diffusion MRI.

Approach: Previous studies have demonstrated that acquiring images with four different PEDs can improve the reproducibility of diffusion derived quantitative maps. This improvement is achieved by averaging across PEDs to reduce the impact of residual EPI Nyquist ghost artifacts.

View Article and Find Full Text PDF

Angle multiplexing is a crucial technique for volume holographic gratings in grating-based lightguide display systems, enabling an extended image field of view (FOV). However, Bragg mismatch diffraction caused by different angle-multiplexed gratings introduces crosstalk, leading to ghost images. In this paper, we analyze the underlying causes of ghost image formation due to angle-multiplexed gratings and propose an optimized recording method to minimize crosstalk noise.

View Article and Find Full Text PDF

Diffusion-weighted GRASE sequence with 3D navigator for high-resolution time-dependent diffusion MRI in the human cortical gray matter.

Magn Reson Med

October 2025

Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China.

Purpose: Oscillating gradient (OG) and pulsed gradient spin-echo diffusion MRI (dMRI) allows the acquisition of diffusion-weighted signals at varying diffusion time (t) and thus enables characterization of microstructure in complex tissues. This study proposed an advanced three-dimensional (3D) navigator-based diffusion-weighted 3D gradient spin-echo (DW-GRASE) sequence, specifically designed for high-resolution whole-brain oscillating gradient spin-echo and pulsed gradient spin-echo acquisition.

Methods: We developed a 3D navigator for phase correction between multiple shots of the 3D DW-GRASE sequence.

View Article and Find Full Text PDF