Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose Of Review: His bundle pacing (HBP) has continued to emerge as a viable alternative to both right ventricular pacing (RVP) and cardiac resynchronization therapy. In recent years, a considerable amount of research has been published with regard to using HBP to treat congestive heart failure (CHF) and this article presents a concise yet comprehensive review of this literature.

Recent Findings: Studies have demonstrated that HBP is useful for CHF patients who are non-responders to biventricular pacing (BiVP) or have a history of previously failed coronary sinus lead placement, right/left bundle branch block cardiomyopathy, or pacing-induced cardiomyopathy. Additionally, HBP is useful in patients with an indication for pacing who are expected to have a RVP burden exceeding 20%. The theoretical benefit of utilizing the native His Purkinje system to excite cardiac tissue is appealing as it can result in true cardiac resynchronization. Limited studies have shown its benefit in reducing heart failure symptoms and improving cardiac function. Larger randomized clinical trials and further investments into developing better technologies are highly desired to make its clinical use sustainable in the long run.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11897-019-0423-2DOI Listing

Publication Analysis

Top Keywords

bundle pacing
8
cardiac resynchronization
8
heart failure
8
pacing heart
4
heart failure-concept
4
failure-concept current
4
current data
4
data purpose
4
purpose review
4
review bundle
4

Similar Publications

Cardiac resynchronization therapy (CRT) improves outcomes in heart failure, but prior interventions like percutaneous mitral annuloplasty may hinder lead placement. We present a 70-year-old male with ischemic cardiomyopathy and severe functional mitral regurgitation who previously received a Carillon device. Due to coronary sinus inaccessibility, left bundle branch area pacing optimized cardiac resynchronization therapy (LOT-CRT) was performed.

View Article and Find Full Text PDF

Background: During the electrode screwing process in left bundle branch pacing (LBBP), the significance of the S wave in lead V6 remains elusive. Our study analyzes the change of the S wave in lead V6 under different patterns of capture and explores its mechanisms.

Methods: This study included 243 cases with criterion of selective LBBP (SLBBP), we performed continuous pacing technique and classified the electrophysiological characteristics observed during the screwing process into four patterns: left ventricular septal pacing (LVSP), non-selective LBBP (NSLBBP) in low output and in the lower output, selective LBBP.

View Article and Find Full Text PDF

Background: Anti-tachycardia pacing (ATP) delivered from implantable cardioverter defibrillators (ICDs) provides critically timed pacing pulses to terminate ventricular tachycardia (VT). Physiological pacing through left bundle branch area (LBBA) pacing has emerged as a clinically relevant alternative to induce synchronous activation of the ventricles. The main objective of this study was to compare the efficacy and safety of ATP delivered to an LBBA lead and a conventional RV lead.

View Article and Find Full Text PDF

Conduction system pacing has emerged as a new pacing technique to achieve cardiac physiologic pacing, but its utility and safety in patients with atrial fibrillation undergoing simultaneous ablation of the atrioventricular node remains seemingly unknown. Here, we present a case series of 10 patients with long-standing persistent or permanent atrial fibrillation who failed rate-control therapy and elected to proceed with simultaneous ablation of the atrioventricular node and His-bundle pacemaker implantation.

View Article and Find Full Text PDF