98%
921
2 minutes
20
We report rapid and mask-free fabrication of a sapphire concave microlens array by a combined method of femtosecond laser holographic processing and wet etching. The method features high fabrication efficiency, as crater arrays can be created on sapphire through a parallel processing manner, and the subsequent wet etching facilitates the formation of microlens arrays with a smooth surface. More importantly, the size and spacing of the concave microlenses can be well tuned by varying the distance of craters and etching time. Two types of microlens arrays with a spacing of 25 and 40 μm have been successfully fabricated, both of which showed good imaging performance. This method holds great promise for developing sapphire-based micro-optical components.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.57.009604 | DOI Listing |
J Refract Surg
September 2025
Purpose: To discuss the technique and outcome of what the authors called the "flap-in-flap" technique and report its safety as a procedure for correction of post-laser in situ keratomileusis (LASIK) myopic regression.
Methods: Seven eyes of 4 patients were included in this study. All patients had previously undergone LASIK for compound myopic astigmatism using the Moria M2 micro-keratome (Moria) 8 to 12 years prior to presentation.
J Refract Surg
September 2025
Department of Refractive Surgery, Aier Eye Hospital, Jinan University, Guangzhou, Guangdong, China.
Purpose: To report the refractive outcome of femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) in correcting moderate to high hyperopia. Intraoperative effective optical zone (EOZ), centration offset, and postoperative higher order aberrations (HOAs) were analyzed to better understand factors affecting postoperative outcomes.
Methods: This was a prospective, consecutive case series study of LIKE for correcting hyperopia in one department from 2018 to 2023.
J Refract Surg
September 2025
American University of Beirut Ophthalmology Department, Beirut, Lebanon.
Purpose: To investigate eye movement dynamics during excimer laser ablation, specifically femtosecond laser-assisted in situ keratomileusis (FS-LASIK), and compare movement patterns between the right eye (always operated on first) and the left eye (operated on second), analyzing direction, magnitude, and temporal changes.
Methods: A retrospective analysis was conducted on 92 eyes from 46 patients who underwent FS-LASIK with the SCHWIND AMARIS system (SCHWIND eye-tech-solutions). Eye-tracking data were collected to record horizontal and vertical directional movements; variability was assessed using standardized metrics.
Vestn Oftalmol
September 2025
Krasnov Research Institute of Eye Diseases, Moscow, Russia.
Modern surgical strategies for keratoconus aim to both stabilize disease progression and correct induced refractive errors. Effectively and simultaneously achieving both goals remains a relevant challenge. This study presents a clinical case of femtosecond laser-assisted intrastromal keratoplasty with implantation of a biosynthetic complex, demonstrating the efficacy of this surgical approach in treating keratoconus.
View Article and Find Full Text PDFJ Chem Phys
September 2025
Department of Chemistry, Indian Institute of Technology Kanpur, Kanpur, India.
We introduce a novel method using a kilohertz (kHz) amplified 800 nm laser for the first experimental confinement of microparticles within a single beam. This study demonstrates that high-energy kHz pulses can confine 1-μm-radius polystyrene beads in water within ∼26 μm. This approach utilizes the unique properties of high-energy pulsed lasers, distinct from continuous-wave and megahertz pulsed lasers traditionally used in optical trapping.
View Article and Find Full Text PDF