Article Abstract

A tracheal tube can be safely replaced by using a tube exchanger (TE). However, only a thin TE can be used to replace a double-lumen tracheal tube (DLT) with a standard single-lumen tracheal tube (SLT). We successfully replaced a DLT to a SLT by inserting an Aintree Intubation Catheter® (AIC) over a TE in two cases. The AIC (diameter : 19 Fr, overall length : 56 cm) is mainly used for the replacement of various supra- glottic apparatuses using a SLT. In our cases, an AIC with an internal diameter of 4.7 mm was placed over a thin TE with an external diameter of 3.7 mm (11 Fr) to increase the support, and the difference between the SLT with an internal diameter of 7.5 mm and an AIC with an external diameter of 6.3 mm (19 Fr) was decreased, resulting in smooth replacement of the tubes. Even for those cases in which tube replacement might be difficult, acute administration of oxygen could be provided using an AIC with a larger internal lumenthan TE. In conclusion, replacement of a DLT with a SLT i safe and useful through the concomitant use of an AI( and a TE.

Download full-text PDF

Source

Publication Analysis

Top Keywords

tracheal tube
16
aintree intubation
8
dlt slt
8
cases aic
8
internal diameter
8
external diameter
8
tube
7
slt
5
aic
5
diameter
5

Similar Publications

Introduction: Endotracheal tube (ETT) cuff pressures that exceed 20-30 cmHO may lead to iatrogenic adverse effects such as cough, sore throat, and tracheal edema or more serious complications including tracheal stenosis, recurrent laryngeal nerve injury, and tracheal rupture. The current study evaluates a novel technique, titration of the ratio of expiratory to inspiratory tidal volumes (TV), to regulate intracuff pressure.

Methods: This prospective, cross-over trial measured intracuff pressure in a cohort of pediatric patients presenting for general anesthesia with an ETT.

View Article and Find Full Text PDF

Tracheal tube cuff materials, shapes, and coatings in the prevention of ventilator-associated pneumonia: a network meta-analysis and systematic review.

Intensive Crit Care Nurs

August 2025

Shuguang Hospital Affliated to Shanghai University of Traditional Chinese Medicine, Clinical Research Center, Shanghai 201203, China. Electronic address:

Objectives: To compare the effectiveness of various endotracheal tube (ETT) cuff materials, shapes, and antimicrobial coatings in preventing ventilator-associated pneumonia (VAP) through a network meta-analysis.

Methods: Six databases were searched up to February 2025 for relevant randomized controlled trials (RCTs). Data analysis was performed using R software.

View Article and Find Full Text PDF

Efficacy of supraglottic airway devices in Chest Compression Synchronized Ventilation during continuous resuscitation: A prospective randomized cross-over cadaver study.

Resuscitation

September 2025

Ruhr University Bochum, Medical Faculty of Ruhr University Bochum, Universitätstraße 150, 44801 Bochum, Germany; University Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Johannes Wesling Klinikum Minden, Ruhr University Bochum, Hans-Nolte-Straße 1, 3

Background: This study aimed to evaluate the efficacy of Chest-Compression-Synchronized-Ventilation (CCSV) using supraglottic airway devices (SGA) compared to tracheal intubation (TI) for ventilation during continuous resuscitation.

Methods: In this cross-over study, the lungs of adult Thiel-embalmed cadavers were initially recruited using TI. Subsequently, various SGA (Laryngeal-Mask=Ambu®AuraGain™, Laryngeal-Tube=LTS-D®, i-gel-Laryngeal-Mask=I-GEL®) and TI were applied in randomized order during continuous chest compressions.

View Article and Find Full Text PDF

Objectives: At present, the available evidence regarding the relationship between prone position ventilation (PPV) and tracheal injury score remains inadequate. This study seeks to gain deeper insights into the relationship between PPV and tracheal injury score in intensive care unit (ICU) patients with invasive ventilation.

Design: A secondary analysis of a prospective cohort study.

View Article and Find Full Text PDF

Tracheal erosion is a rare but life-threatening complication of prolonged endotracheal intubation, especially in medically complex patients. We report a case of a 70-year-old male with multiple comorbidities, including bilateral cerebellar stroke, multi-infarct dementia, and heart failure with reduced ejection fraction, who developed tracheal erosion secondary to prolonged endotracheal intubation of 265 days. Computed tomography revealed that the endotracheal tube had pierced the anterior wall of the trachea.