Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The ACR Dose Index Registry (DIR) provides a new source of clinical radiation exposure data that has not been used previously to establish or update the relative radiation level (RRL) values in the ACR Appropriateness Criteria (AC). The results of a recent review of DIR data for 10 common CT examinations were compared with current ACR AC RRL values for the same procedures. The AC RRL values were previously determined by consensus of members of the AC Radiation Exposure Subcommittee based on reference radiation dose values from the literature (when available) and anecdotal information from individual members' clinical practices and experiences. For 7 of the 10 examination types reviewed, DIR data agreed with existing RRL values. For 3 of 10 examination types, DIR data reflected lower dose values than currently rated in the AC. The Radiation Exposure Subcommittee will revise these RRL assignments in a forthcoming update to the AC (in October 2018) and will continue to monitor the DIR and associated reviews and analyses to refine RRL assignments for additional examination types. Given recent attention and efforts to reduce radiation exposure in CT and other imaging modalities, it is likely that other examination types will require revision of RRL assignments once information from the DIR database is considered.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacr.2018.08.008DOI Listing

Publication Analysis

Top Keywords

radiation exposure
20
rrl values
16
examination types
16
exposure subcommittee
12
dir data
12
rrl assignments
12
radiation
8
relative radiation
8
acr dose
8
dose registry
8

Similar Publications

Radiation exposure initiates a cascade of reactions, including the release of reactive oxygen species, DNA double-strand breaks, and cellular apoptosis, leading to cell death, tissue damage, and potentially the development of cancer. Consequently, there is an urgent need to develop highly effective and low-toxicity radioprotective agents. Traditional chemically synthesized protective agents face significant limitations in clinical applicability due to their pronounced off-target toxicity, narrow therapeutic window, and high production costs.

View Article and Find Full Text PDF

Chili pepper exports from Ghana are subject to stringent chemical residue regulations in key export destinations. Consequently, microbial biopesticides are urgently needed to complement current nonchemical control options for key pests of chili pepper, particularly the phytosanitary insect, False Codling Moth (FCM). Thus, the search for native entomopathogenic fungi in Ghanaian farms was initiated in 2023.

View Article and Find Full Text PDF

Background: Ultraviolet-C (UV-C) radiation has emerged as a widely adopted disinfection technology in healthcare settings due to its germicidal effectiveness. However, concerns have grown regarding the potential degradation of materials, particularly polymeric surfaces, subjected to repeated UV-C exposure. Understanding the extent, mechanism, and contributing factors of UV-C-induced material degradation is essential for safe and sustainable implementation.

View Article and Find Full Text PDF

Objective: The present study aimed to compare the accuracy of the Paprosky Classification of Femoral Bone Loss using plain radiographs and two-dimensional computed tomography (2D CT) images with the femoral defect observed intraoperatively by the surgeon.

Methods: There were 14 hip surgeons from the same hospital who classified 80 patients with an indication for revision hip arthroplasty according to Paprosky based on plain radiographs in anteroposterior views of the pelvis and 2D CT images, reconstructed in the axial, coronal, and sagittal planes. We compared this data with the intraoperative findings of femoral bone loss by the same surgeons.

View Article and Find Full Text PDF

Objective: The present study aimed to compare the accuracy of the Paprosky Classification of Femoral Bone Loss using plain radiographs and two-dimensional computed tomography (2D CT) images with the femoral defect observed intraoperatively by the surgeon.

Methods: There were 14 hip surgeons from the same hospital who classified 80 patients with an indication for revision hip arthroplasty according to Paprosky based on plain radiographs in anteroposterior views of the pelvis and 2D CT images, reconstructed in the axial, coronal, and sagittal planes. We compared this data with the intraoperative findings of femoral bone loss by the same surgeons.

View Article and Find Full Text PDF