Article Abstract

Screening for hepatopulmonary syndrome (HPS) using pulse oximetry is recommended in liver transplant (LT) candidates because mortality is increased, independently of the severity of the oxygenation defect. LT exception points may be afforded to those with HPS and severe hypoxemia. We assessed the screening characteristics of pulse oximetry for HPS. The Pulmonary Vascular Complications of Liver Disease 2 study is a multicenter, prospective cohort study of adults undergoing their first LT evaluation. Patients underwent protocolized assessment of oxygen saturation by pulse oximetry (SpO ), arterial blood gas, spirometry, and contrast-enhanced echocardiography (CE). HPS was defined as an alveolar-arterial gradient ≥15 mm Hg (≥20 mm Hg if age >64 years), intrapulmonary vascular dilatation on CE, and absence of lung disease. The study sample included 363 patients. Of these, 75 (20.7%; 95% confidence interval [CI], 16.6%-25.2%) met the criteria for HPS. The area under the receiver operating characteristic curve (or c-statistic) for SpO in discriminating HPS was 0.59 (95% CI, 0.51-0.66). An SpO <96%, recommended by practice guidelines as a threshold to require further testing, had low sensitivity (28%; 95% CI, 18%-28%). The c-statistic of SpO in discriminating HPS with a partial pressure of oxygen (PaO ) <60 mm Hg (eligible for LT exception points) was 0.76 (95% CI, 0.46-1.00). An SpO cutoff of <96% had higher sensitivity for detecting HPS with PaO <60 mm Hg (71%; 95% CI, 38%-100%) but was still inadequate. Conclusion: Pulse oximetry is not sufficiently sensitive to screen for HPS in LT candidates. Arterial blood gas and CE are required in LT candidates for diagnosis of HPS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6652183PMC
http://dx.doi.org/10.1002/hep.30139DOI Listing

Publication Analysis

Top Keywords

pulse oximetry
16
hepatopulmonary syndrome
8
disease study
8
hps
6
pulse
4
oximetry insensitive
4
insensitive detection
4
detection hepatopulmonary
4
syndrome patients
4
patients evaluated
4

Similar Publications

Background: Nocturnal SpO monitoring is recommended for detecting residual sleep-disordered breathing (SDB), including nocturnal hypoventilation, in patients treated by non-invasive ventilation (NIV) or continuous positive airway pressure (CPAP). It is a general assumption that different pulse oximetry devices will provide similar results. This may, however, not be correct.

View Article and Find Full Text PDF

Point-of-Care Ultrasound Optimizes the Preoperative Use of Prostaglandin E1 in Infants With Transposition of the Great Arteries.

Rev Cardiovasc Med

August 2025

Department of Neonatology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080 Guangzhou, Guangdong, China.

Background: This study aimed to determine the optimal dosages of prostaglandin E1 required to maintain a patent ductus arteriosus (PDA) in infants with transposition of the great arteries (TGA) based on point-of-care ultrasound (POCUS) findings.

Methods: Infants with TGA were recruited from two groups (the historical control group and the POCUS group that received POCUS in combination with pulse oximetry saturation (SpO) to titrate the dose of prostaglandin E1 (PGE1)).

Results: A total of 150 patients were included in this study.

View Article and Find Full Text PDF

Harlequin syndrome, also known as differential hypoxia (DH) or North-South syndrome, is a serious complication of femoro-femoral venoarterial extracorporeal membrane oxygenation (V-A ECMO). Moreover, Harlequin syndrome is caused by competing flows between the retrograde oxygenated ECMO output and the anterograde ejection of poorly oxygenated blood from the native heart. In the setting of impaired pulmonary gas exchange, the addition of an Impella device (ECPELLA configuration), although beneficial for ventricular unloading and hemodynamic support, may further exacerbate this competition and precipitate DH.

View Article and Find Full Text PDF

Methemoglobinemia is an uncommon yet potentially life-threatening condition that results from the oxidation of iron from the ferrous (Fe²⁺) to the ferric (Fe³⁺) state, rendering hemoglobin unable to effectively transport oxygen. This translates into a state of functional hypoxia despite adequate arterial oxygen tension. Among the various causes of acquired methemoglobinemia, recreational inhalation of alkyl nitrites, widely known as "poppers," is a notable but underrecognized trigger.

View Article and Find Full Text PDF

Purpose: To assess the association between skeletal-muscle endurance performance and mitochondrial oxidative capacity of the hamstrings as respectively measured by biomechanical and physiological standards.

Methods: Nineteen (12 men and 7 women) healthy, young, recreationally active participants enrolled in our study. Participant characteristics comprised a mean and SD age of 21.

View Article and Find Full Text PDF