98%
921
2 minutes
20
In this study, a plastic microdevice based on loop-mediated isothermal amplification (LAMP) was fabricated for the amplification and on-chip fluorescence detection of multiple pathogens. Papers infused with LAMP reagents and specific primers were embedded inside the multiple reaction chambers of the microdevice. A solution containing the target pathogens was injected into the sample chamber, located in the center of the microdevice, and evenly distributed to the reaction chambers simultaneously via centrifugal force. For detection, fisetin, a plant-derived fluorophore, was used as the DNA-intercalating dye. Purified DNAs of Escherichia coli O157:H7 (E. coli O157:H7), Salmonella spp., Staphylococcus aureus (S. aureus), and Cochlodinium polykrikoides were successfully amplified and directly detected on the microdevice, where as low as 0.13 and 0.12 ng μL-1 of the DNA of E. coli O157:H7 and S. aureus, respectively, were identified. In addition, the potential of this microdevice for point-of-care testing was further examined by incorporating on-chip sample purification module and testing using a real sample - milk spiked with Salmonella spp. The thermally lysed milk sample was filtered using polydopamine-coated paper embedded inside a sample chamber and seamlessly transported into the reaction chambers by centrifugal force for subsequent LAMP followed by direct on-chip detection inside the reaction chambers in which fisetin-soaked papers were embedded. The limit of detection for Salmonella spp. was determined to be approximately 1.7 × 102 CFU mL-1 using the microdevice. This microdevice is safe, easy to use, selective, and sensitive enough for point-of-care testing to identify foodborne pathogens as well as environmentally harmful microorganisms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c8lc00424b | DOI Listing |
Cornea
September 2025
Department of Ophthalmology, Ewha Womans University Mokdong Hospital, Ewha Womans University College of Medicine, Seoul, Korea.
Purpose: To report a case of Epstein-Barr virus (EBV) corneal endotheliitis and uveitis in a patient diagnosed with extranodal natural killer/T-cell lymphoma (ENKTL).
Methods: This is a case report performed at a tertiary care center in the Republic of Korea.
Results: A 64-year-old man presented with decreased vision in his right eye that had persisted for 4 days.
Med Sci Sports Exerc
September 2025
Department of Physical Therapy, University of Pittsburgh, Pittsburgh, PA.
Background: Osteoarthritis is a leading cause of disability and is accompanied by pain, high medical expenditures, and poor quality of life. Adults with obesity develop osteoarthritis at twice the rate of normal weight adults, in part due to higher joint loading. Middle-aged adults have the highest prevalence of obesity among adult age groups.
View Article and Find Full Text PDFJ Hazard Mater
August 2025
College of Mechanical Engineering, Guangxi University, Nanning 530004, China. Electronic address:
This research addresses the soot emission challenges of conventional internal combustion engines by incorporating Fe-based metal-organic frameworks (Fe-MOFs) into alcohol-based fuel. In a constant volume combustion chamber, optical diagnostic methods were employed to examine the spray properties, combustion dynamics, and emission profiles of fuel mixtures with Fe-MOFs concentrations of 20 ppm, 40 ppm, and 60 ppm. Additionally, a BO-GPR algorithm was employed to predict emission outcomes.
View Article and Find Full Text PDFBiosens Bioelectron
December 2025
Life Science Center, Vilnius University, Saulėtekio al. 7, LT-10257, Vilnius, Lithuania. Electronic address:
The total pool of blood's serum circulating L-amino acids (ΣAA) is an underused biomarker that integrates muscle protein turnover, nutritional status and metabolic disorders. Despite increasing clinical relevance, current methods for quantifying ΣAA, including colorimetry/fluorimetry and chromatography, are laboratory-bound, slow, and unsuitable for decentralized or extreme environments such as space missions. We report a self-contained, portable, calibration-free prototype device - Aminometer - for rapid quantitative analysis of ΣAA concentration in 7.
View Article and Find Full Text PDFNanocarriers hold transformative potential for treating anterior segment eye diseases, yet corneal epithelium impermeability necessitates intraocular injection. Given the discomfort and infection risk, an injectable hydrogel-based depot offers a promising strategy for sustained nanocarrier delivery in intraocular therapy. However, because the aqueous humor is a large, fluid-filled environment, achieving spatially confined gelation remains a key challenge as injected materials rapidly diffuse.
View Article and Find Full Text PDF