Article Abstract

Objectives: In this study, the authors performed a meta-analysis of currently available comparative prospective studies to assess the efficacy and safety of exercise training in heart failure (HF) patients with implantable cardioverter-defibrillators (ICD).

Background: ICDs have been shown to improve survival in patients with HF. However, many patients with ICDs experience fear of shocks and avoid physical activity. Few data exist for efficacy and safety of exercise training in HF patients with ICDs.

Methods: Prospective parallel arm trials with control and exercise training groups that evaluated the efficacy of exercise training in patients with ICDs were included in the meta-analysis. Outcomes of interest were difference in the change in cardiorespiratory fitness (CRF) (ml/kg/min) between exercise and control group and the likelihood of ICD shocks among exercise training compared with that among control participants on follow-up.

Results: We included study level data from 6 trials (5 randomized controlled trials and 1 nonrandomized controlled trial). In the pooled analysis, ICD patients undergoing exercise training had significant improvement in CRF (weighted mean difference: 1.98 ml/kg/min; 95% confidence interval [CI]: 0.58 to 3.38). The likelihood of ICD shocks on follow-up was also significantly lower among exercise training than among control participants (pooled odds ratio: 0.47; 95% CI: 0.24 to 0.91).

Conclusions: Among patients with HF and ICD implantation, exercise training was associated with significant improvement in CRF and lower likelihood of ICD shocks.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacep.2016.06.008DOI Listing

Publication Analysis

Top Keywords

exercise training
32
likelihood icd
12
icd shocks
12
exercise
9
efficacy safety
8
safety exercise
8
training
8
patients icds
8
training patients
8
control participants
8

Similar Publications

Background: Bridge preparation skills are a vital component of dental education and require specific techniques. This study aimed to develop and evaluate 3D printed teeth for use in defect-oriented bridge preparation and pre-prosthetic exercises in dental training, addressing the limited customization and lack of integrated workflows found in commercial typodont teeth. The null hypothesis stated that 3D printed teeth offered no advantage over established typodont training methods for bridge preparation.

View Article and Find Full Text PDF

Slowing down the clock on ovarian aging-does the ovary hold the secret to the fountain of youth?

Geroscience

September 2025

NUS Bia-Echo Asia Centre for Reproductive Longevity and Equality, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.

In the past century, the human Lifespan has doubled. However, this is not equivalent to Healthspan which refers to the number of years spent healthy and free from disease. Women have an additional level of complexity on the path to optimal healthspan where health resilience dramatically decreases following menopause and this is due to their ovaries aging by midlife.

View Article and Find Full Text PDF

Purpose: We developed a diet quality index based on the Planetary Health Diet (PHD) to assess healthy and sustainable diets. The index was applied alongside socio-demographic characteristics in five regions across Europe and North Africa.

Methods: The Sustainable Healthy Diet Index (SHDI) was designed using existing and validated healthy diet indexes.

View Article and Find Full Text PDF