Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background/aims: The position of the tip of tunnelled haemodialysis (HD) catheters (THC) might influence flow characteristics during HD. In chest X-ray (CXR), carina-related landmarks may be practicable to verify the THC position, and tip-carina distance (TCD) might be useful to predict early-flow dysfunctions.

Methods: In this single-centre, retrospective study, the TCD and the angle between the distal catheter and the body vertical axis (tip-body vertical-angle [TVA]) was measured in 115 THC by post-procedure CXR with 2 investigators. The parameters were proved to be feasible by interrater-reliability and correlated with the incidence of flow-dysfunction within 10 days after insertion.

Results: Steep-aligned (TVA <40°, p < 0.01) and deep-ending catheters (TCD: right-sighted >1.5 cm or left-sighted >4.5 cm below the carina; p < 0.01) showed a significantly less dysfunction with a good interrater-reliability (R[TVA] = 0.8, R[TCD] = 0.9).

Conclusions: Carina-related landmarks in CXR might be helpful to predict early-flow dysfunctions. However, randomized studies will be necessary to confirm this in fluoroscopic-guided placement during the insertion of THC.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000486845DOI Listing

Publication Analysis

Top Keywords

tunnelled haemodialysis
8
haemodialysis catheters
8
chest x-ray
8
carina-related landmarks
8
predict early-flow
8
early flow
4
flow disturbances
4
disturbances tunnelled
4
catheters topographic
4
topographic landmarks
4

Similar Publications

Rationale: This case report aims to highlight a rare but life-threatening complication of femoral venous catheterization and to describe a novel endovascular technique for its management. Non-tunneled femoral catheters provide rapid vascular access for emergency dialysis (e.g.

View Article and Find Full Text PDF

CHRFS5, HL_CHRU_S18, S48B, HL_CHRU_S16, S19, HL_CHRU_S79, and HL_CHRU_S111 were isolated from the biofilm of catheter tip of renal failure patients. Whole genome sequencing predicted the presence of multiple antibiotic-resistant gene cassettes.

View Article and Find Full Text PDF

Objectives: As a two-dimensional modality, venography has limitations in its capacity to measure lumen caliber and to assess stenotic disease accurately. This has implications in the management of end-stage renal-disease (ESRD) patients "no-option" candidates access for arteriovenous fistula (AVF) or graft (AVG) creation secondary to high risk of vascular access failure. The incremental diagnostic and clinical impact of intravascular ultrasound (IVUS) was quantified in this tunneled dialysis catheter dependent ESRD cohort.

View Article and Find Full Text PDF

Objective: Upper-extremity arteriovenous (AV) access often requires re-intervention. However, the frequency of re-interventions and subsequent access failure is not well-characterized. Our goal was to evaluate the frequency and type of re-interventions, risk-factors, and outcomes after AV access creation.

View Article and Find Full Text PDF

As a widely used vascular access for hemodialysis patients, arteriovenous fistula (AVF) still faces high failure rates, in which local inflammatory response is an essential factor. In animal studies, chronic kidney disease (CKD) has been reported to aggravate local inflammation in AVFs, but the mechanisms are controversial. Here, spatial transcriptomics and single-cell RNA sequencing are used to explore the cellular changes during AVF remodeling in human and mouse.

View Article and Find Full Text PDF