Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Density changes occurring during fractionated radiotherapy in the pelvic region may degrade proton dose distributions. The aim of the study was to quantify the dosimetric impact of gas cavities and body outline variations.

Material And Methods: Seven patients with locally advanced cervical cancer (LACC) were analyzed through a total of 175 daily cone beam computed tomography (CBCT) scans. Four-beams intensity-modulated proton therapy (IMPT) dose plans were generated targeting the internal target volume (ITV) composed of: primary tumor, elective and pathological nodes. The planned dose was 45 Gy [Relative-Biological-Effectiveness-weighted (RBE)] in 25 fractions and simultaneously integrated boosts of pathologic lymph nodes were 55-57.5 Gy (RBE). In total, 475 modified CTs were generated to evaluate the effect of: 1/gas cavities, 2/outline variations and 3/the two combined. The anatomy of each fraction was simulated by propagating gas cavities contours and body outlines from each daily CBCT to the pCT. Hounsfield units corresponding to gas and fat were assigned to the propagated contours. D98 (least dose received by the hottest 98% of the volume) and D99.9 for targets and V43Gy(RBE) (volume receiving ≥43 Gy(RBE)) for organs at risk (OARs) were recalculated on each modified CT, and total dose was evaluated through dose volume histogram (DVH) addition across all fractions.

Results: Weight changes during radiotherapy were between -3.1% and 1.2%. Gas cavities and outline variations induced a median [range] dose degradation for ITV45 of 1.0% [0.5-3.5%] for D98 and 2.1% [0.8-6.4%] for D99.9. Outline variations had larger dosimetric impact than gas cavities. Worst nodal dose degradation was 2.0% for D98 and 2.3% for D99.9. The impact on bladder, bowel and rectum was limited with V43Gy(RBE) variations ≤3.5 cm.

Conclusion: Bowel gas cavities and outline variations had minor impact on accumulated dose in targets and OAR of four-field IMPT in a LACC population of moderate weight changes.

Download full-text PDF

Source
http://dx.doi.org/10.1080/0284186X.2017.1376753DOI Listing

Publication Analysis

Top Keywords

gas cavities
20
outline variations
16
dose
10
bowel gas
8
body outline
8
accumulated dose
8
intensity-modulated proton
8
proton therapy
8
locally advanced
8
advanced cervical
8

Similar Publications

Rescue pneumatic retinopexy for recurrent retinal detachments due to superior retinal breaks following initial vitrectomy.

Jpn J Ophthalmol

September 2025

Kyorin Eye Center, School of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.

Purpose: To evaluate the clinical outcomes of pneumatic retinopexy (PnR) for a recurrent rhegmatogenous retinal detachment (RRD) due to superior retinal breaks following initial vitrectomy for a RRD.

Study Design: Clinical investigations.

Methods: A retrospective study of 82 eyes of 82 patients who underwent vitrectomy by a single surgeon between November 2021 and March 2023.

View Article and Find Full Text PDF

OH-stretching overtone spectra of primary and secondary alcohols.

Spectrochim Acta A Mol Biomol Spectrosc

September 2025

Department of Chemistry, University of Copenhagen, Universitetsparken 5, Copenhagen-Ø, DK-2100, Denmark. Electronic address:

Absorption spectra of neopentyl alcohol and pinacolyl alcohol are recorded in the gas phase at room temperature and equilibrium conditions. A combination of conventional Fourier transform spectroscopy and cavity ringdown spectroscopy is used to cover the spectral OH-stretching regions, Δv=1-5. The conformer distributions of the alcohols are determined from the recorded spectra combined with transition intensities calculated with a reduced dimensional local mode model.

View Article and Find Full Text PDF

Porous Janus membrane for ultrasensitive detection and efficient degradation of sulfur mustard simulant.

J Hazard Mater

August 2025

Qilu University of Technology (Shandong Academy of Sciences), Shandong Analysis and Test Center, Jinan, Shandong 250014, China. Electronic address:

The development of integrated systems for simultaneous chemical threat detection and decontamination is hindered by inherent sensitivity-efficiency trade-offs. We address this challenge through interfacial engineering of a Janus membrane combining D-A molecule functionalized MOFs with PDMS. A gas-liquid interfacial self-assembly strategy enables the creation of a microporous PDMS top layer for vapor preconcentration and vertically aligned MOF nanochannels (2.

View Article and Find Full Text PDF

An exceptional case of sudden death due to pseudo-Meigs syndrome.

J Forensic Sci

September 2025

Cook County Medical Examiner's Office, Chicago, Illinois, USA.

Pseudo-Meigs syndrome is a rare clinical entity characterized by the triad of ascites, pleural effusion, and a benign pelvic tumor other than an ovarian fibroma. Although typically considered benign and reversible following tumor removal, the syndrome can result in severe life-threatening compromise if unrecognized or untreated. Unlike the classical Meigs syndrome, which has occasionally been associated with fatal outcomes, no deaths related to pseudo-Meigs syndrome due to benign tumors have been previously reported.

View Article and Find Full Text PDF

In vitro and in vivo degradation behavior of an assembled magnesium alloy suture anchor for ligament-bone reconstruction.

Acta Biomater

August 2025

School of Material Science and Engineering, Zhengzhou University, Zhengzhou, 450001, China; Henan Key Laboratory of Advanced Light Alloys, Zhengzhou 450002, China; Zhongyuan Critical Metals Laboratory, Zhengzhou 450001, China. Electronic address:

Biodegradable magnesium alloys suture anchors face rapid anchor eyelet degradation, compromising mechanical strength. In this study, an assembled-structure magnesium alloy suture anchor was proposed to mitigate the fast failure of anchor eyelet. In vitro and in vivo experiments were conducted to evaluate the degradation behavior and biomechanical performance of assembled ZE21C magnesium alloy suture anchors.

View Article and Find Full Text PDF