98%
921
2 minutes
20
Classic studies in bone mechanobiology have established the importance of loading parameters on the anabolic response. Most of these early studies were done using loading methods not currently in favor, and using non-murine species. Our objective was to re-examine the effects of several loading parameters on the response of cortical bone using the contemporary murine axial tibial compression model. We subjected tibias of 5-month old, female C57Bl/6 mice to cyclic (4 Hz) mechanical loading and examined bone formation responses using dynamic and static histomorphometry. First, using a reference protocol of 1,200 cycles/day, 5 days/week for 2 weeks, we confirmed the significant influence of peak strain magnitude on periosteal mineralizing surface (Ps.MS/BS) and bone formation rate (Ps.BFR/BS) (p < 0.05, ANOVA). There was a significant induction of periosteal lamellar bone at a lower threshold of approx. -1,000 μϵ and a transition from lamellar-woven bone near -2,000 μϵ. In contrast, on the endocortical surface, bone formation indices did not exhibit a load magnitude-dependent response and no incidence of woven bone. Next, we found that reducing daily cycle number from 1,200 to 300 to 60 did not diminish the bone formation response (p > 0.05). On the other hand, reducing the daily frequency of loading from 5 consecutive days/week to 3 alternate days/week significantly diminished the periosteal response, from a loading-induced increase in Ps.MS/BS of 38% (loaded vs. control) for 5 days/week to only 15% for 3 days/week (p < 0.05). Finally, we determined that reducing the study duration from 2 to 1 weeks of loading did not affect bone formation outcomes. In conclusion, cyclic loading to -1,800 μϵ peak strain, at 4 Hz and 60 cycles/day for 5 consecutive days (1 week) induces an increase in periosteal lamellar bone formation with minimal incidence of woven bone in 5-month-old C57Bl/6 female mice. Our results provide a basis for reduction of loading duration (daily cycles and study length) without loss of anabolic effect as measured by dynamic histomorphometry. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:682-691, 2018.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5839947 | PMC |
http://dx.doi.org/10.1002/jor.23727 | DOI Listing |
J Control Release
September 2025
Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G9, Canada; The Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Unity Health Toronto, Toronto, Ontario M5B 1T8, Canada; Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M
Microfluidic hydrodynamic focusing (HF) has emerged as a powerful platform for the controlled synthesis of lipid nanoparticles (LNPs) and liposomes, offering superior precision, reproducibility, and scalability compared to traditional batch methods. However, the impact of HF inlet configuration and channel geometry on nanoparticle formation remains poorly understood. In this study, we present a comprehensive experimental and computational analysis comparing 2-inlet (2-way) and 4-inlet (4-way) HF designs across various sheath inlet angles (45°, 90°, 135°) and cross-sectional geometries (square vs.
View Article and Find Full Text PDFJ Environ Manage
September 2025
National and Local Joint Engineering Laboratory of Municipal Sewage Resource Utilization Technology, Jiangsu Collaborative Innovation Center of Technology and Material of Water Treatment, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, 215009, Ch
The anaerobic ammonia oxidation (anammox) process has attracted considerable interest for its advantages in low energy requirements, reduced sludge output, and eliminating the need for external carbon sources. However, its application is constrained by the long generation time, slow growth, and challenges in enriching anammox bacteria. Studies indicate that carbon material addition significantly accelerates anammox bacteria proliferation, enhances nitrogen removal efficiency, and improves anammox microbial activity.
View Article and Find Full Text PDFFront Bioeng Biotechnol
August 2025
Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, China.
Objective: Due to its inherent high instability, the selection of fixation strategies for unilateral Denis type II sacral fractures remains a controversial challenge in the field of traumatic orthopedics. This study focuses on unilateral Denis type II sacral fractures. By applying three different fixation methods, it aims to explore their biomechanical properties and provide a theoretical basis for optimizing clinical fixation protocols.
View Article and Find Full Text PDFVet World
July 2025
Department of Geography, University College London, United Kingdom.
Background And Aim: Hospital effluents are a major source of environmental contaminants, harboring pathogenic bacteria, toxic trace metals, and high organic loads. This study aimed to evaluate the bacteriological and physicochemical profiles of wastewater discharged from three coastal hospitals in Oran, Algeria, and to assess the associated public and livestock health risks under the One Health approach.
Materials And Methods: A cross-sectional study was conducted from January 2023 to February 2024, involving monthly sampling at three hospitals and one drainage collector.
Aerosp Med Hum Perform
September 2025
Introduction: Military fast jet pilots face significant physical challenges, including high Gz accelerations during dynamic maneuvers. The objectives of this study were threefold: 1) to record pilot movements during real flights, 2) to quantify head and trunk movements under standardized Gz conditions and during basic fighter maneuvers (BFMs), and 3) to categorize compensatory strategies used to mitigate physical strain.
Methods: A total of 20 Eurofighter pilots (mean age: 28.