Optimization of Tube Current in Cone-beam Computed Tomography for the Detection of Vertical Root Fractures with Different Intracanal Materials.

J Endod

Department of Stomatology, Public Oral Health, and Forensic Dentistry School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil. Electronic address:

Published: October 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: There is no consensus about the accuracy of cone-beam computed tomography (CBCT) for detecting vertical root fractures (VRFs), nor is there certainty about the isolated effect of different tube current parameters on the diagnosis of VRF through CBCT scans. This study aimed to evaluate how tube current affects the detection of VRF on CBCT examinations in the absence of intracanal materials and in the presence of gutta-percha (GP) and metal (MP) or fiberglass (FP) intracanal posts.

Methods: The sample consisted of 320 CBCT scans of tooth roots with and without VRF divided into 8 groups: no fracture/no intracanal material; no fracture + GP; no fracture + MP; no fracture + FP; fracture/no intracanal material; fracture + GP; fracture + MP; fracture + FP. The scans were acquired with an OP300 unit using 4 different milliamperes (4 mA, 8 mA, 10 mA, 13 mA). Five oral radiologists analyzed the images. The area under the receiver operating characteristic curve (Az), sensitivity, specificity, positive and negative predictive values, and interobserver agreement were calculated.

Results: Diagnostic performance for the different milliamperes tested was similar for teeth without root filling materials or with FP. Teeth with GP and MP showed the highest Az values for 8 mA and 10 mA, respectively. For teeth with MP, specificity was significantly higher when 10 mA was used.

Conclusions: For teeth without root filling materials or with FP, the use of a reduced milliampere does not seem to influence the detection of VRF in a significant manner. For teeth with GP and MP, an increased milliampere may lead to increased diagnostic performance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2017.04.003DOI Listing

Publication Analysis

Top Keywords

tube current
12
cone-beam computed
8
computed tomography
8
vertical root
8
root fractures
8
intracanal materials
8
vrf cbct
8
cbct scans
8
detection vrf
8
fracture/no intracanal
8

Similar Publications

A soft robotic device for rapid and self-guided intubation.

Sci Transl Med

September 2025

Department of Mechanical Engineering, University of California, Santa Barbara, Santa Barbara, CA 93106, USA.

Endotracheal intubation is a critical medical procedure for protecting a patient's airway. Current intubation technology requires extensive anatomical knowledge, training, technical skill, and a clear view of the glottic opening. However, all of these may be limited during emergency care for trauma and cardiac arrest outside the hospital, where first-pass failure is nearly 35%.

View Article and Find Full Text PDF

Introduction: It is well known that Obstructive Sleep Apnea (OSA) is a complex disease characterized by an Upper Airway (UA) collapse during sleep, with potential consequences on ENT districts. Recent evidence suggests a possible association with Eustachian Tube Dysfunction (ETD). However, the potential effects of both surgical and non-surgical therapeutic strategies on ET function remain poorly explored in the current literature.

View Article and Find Full Text PDF

Background: Certain scientific publications suggest that medications with high protein binding, such as phenytoin, have lower-than-expected serum levels in patients receiving enteral nutrition (EN) preparations or nutritional supplements. Valproic acid (VPA) is highly protein bound but currently no interactions with EN that would reduce serum levels have been documented.

Case Description: A 69-year-old patient receiving enteral VPA oral solution via a nasojejunal tube experienced a clinically significant decrease in serum concentration when EN was initiated.

View Article and Find Full Text PDF

Background: Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide. The tumor microenvironment (TME), particularly the interactions between endothelial cells and cancer-associated fibroblasts (CAFs), plays a pivotal role in promoting tumor growth, angiogenesis, oxidative stress, and therapy resistance. The HUVEC-fibroblast co-culture model closely mimics stromal-endothelial interactions observed in CRC, enabling mechanistic insights not achievable in monocultures.

View Article and Find Full Text PDF

Thermal imaging for estimating melting point in cheese: A cost-effective alternative to rheology.

JDS Commun

September 2025

Dairy and Food Science Department, Midwest Dairy Foods Research Center, South Dakota State University, Brookings, SD 57007.

The melting characteristics of cheese play a pivotal role in determining functional performance in various applications. Measuring the meltability and melting point of cheese is a challenge and requires sophisticated equipment, a laboratory setup, and personnel training, and the cost can be prohibitive. Over the years, many tests have been developed to determine the meltability or melting point of cheese.

View Article and Find Full Text PDF