Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Endotracheal intubation is a critical medical procedure for protecting a patient's airway. Current intubation technology requires extensive anatomical knowledge, training, technical skill, and a clear view of the glottic opening. However, all of these may be limited during emergency care for trauma and cardiac arrest outside the hospital, where first-pass failure is nearly 35%. To address this challenge, we designed a soft robotic device to autonomously guide a breathing tube into the trachea with the goal of allowing rapid, repeatable, and safe intubation without the need for extensive training, skill, anatomical knowledge, or a glottic view. During initial device testing with highly trained users in a mannequin and a cadaver, we found a 100% success rate and an average intubation duration of under 8 s. We then conducted a preliminary study comparing the device with video laryngoscopy, in which prehospital medical providers with 5 min of device training intubated cadavers. When using the device, users achieved an 87% first-pass success rate and a 96% overall success rate, requiring an average of 1.1 attempts and 21 s for successful intubation, significantly ( = 0.008) faster than with video laryngoscopy. When using video laryngoscopy, the users achieved a 63% first-pass success rate and a 92% overall success rate, requiring an average of 1.6 attempts and 44 s for successful intubation. This preliminary study offers directions for future clinical studies, the next step in testing a device that could address the critical needs of emergency airway management and help democratize intubation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1126/scitranslmed.ads7681 | DOI Listing |