Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Nitric oxide (NO) is an important signaling molecule occurring in virtually all organisms, whose mechanism of action relies mainly on its interaction with proteins or peptides by nitrosylation, forming compounds such as S-nitrosothiols (SNO). The Saville reaction and the ozone-based chemiluminescence method are the main techniques used for nitrosylated protein quantification. While the Saville assay is not very sensitive, the ozone-based chemiluminescence is expensive and time-consuming. Here we propose a method in which the protein-bound NO groups are exposed to UV light, cleaving the bond and allowing the quantification of the derived NO molecules by diamino-rhodamine (DAR) dyes. The DAR-based method was shown to be specific in plant tissues by pre-treatment of the samples with reducing agents and parallel EPR analysis. Spike-and-recovery assays revealed 72% recovery after a GSNO spike. Moreover, the method was significantly more sensitive than the Saville reaction, and this increase in sensitivity was crucial for detecting the reduced levels of nitrosylated proteins in plant species other than Arabidopsis. The method presented here is a suitable alternative to compare plant samples, allowing simple and fast detection of nitrosylated proteins.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.niox.2017.03.001DOI Listing

Publication Analysis

Top Keywords

saville reaction
8
ozone-based chemiluminescence
8
nitrosylated proteins
8
method
6
alternative fluorimetric-based
4
fluorimetric-based method
4
method detect
4
detect compare
4
compare total
4
total s-nitrosothiols
4

Similar Publications

Multiple respiratory viruses lead to high morbidity and mortality, yet global surveillance platforms focus primarily on seasonal influenza viruses. The COVID-19 pandemic and new RSV vaccines highlight the importance of a broader approach. Upper respiratory tract swabs from children aged 24-59 months presenting with influenza-like illness in The Gambia were collected during follow-up of a live-attenuated influenza vaccine randomised controlled trial in 2017-18.

View Article and Find Full Text PDF

Setrusumab for the treatment of osteogenesis imperfecta: 12-month results from the phase 2b asteroid study.

J Bone Miner Res

September 2024

Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Wellington Square, Oxford OX1 2JD, United Kingdom.

Article Synopsis
  • * The phase 2b Asteroid study tested the efficacy and safety of the drug setrusumab in adults with OI, providing different doses of the drug or a placebo over 12 months.
  • * Results showed significant improvements in bone strength measures like failure load and stiffness for certain doses, and although there were some serious adverse reactions, the drug shows promise for further research in phase 3 trials.
View Article and Find Full Text PDF

Cutaneous hypersensitivity reactions represent the most common manifestation of drug allergy seen in the clinic, with 25% of all adverse drug reactions appearing in the skin. The severity of cutaneous eruptions can vastly differ depending on the cellular mechanisms involved from a minor, self-resolving maculopapular rash to major, life-threatening pathologies such as the T-cell mediated bullous eruptions, i.e.

View Article and Find Full Text PDF

Integrated microneedle-smartphone nucleic acid amplification platform for in-field diagnosis of plant diseases.

Biosens Bioelectron

September 2021

Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC, 27696, USA; Emerging Plant Disease and Global Food Security Cluster, North Carolina State University, Raleigh, NC, 27696, USA. Electronic address:

We demonstrate an integrated microneedle (MN)-smartphone nucleic acid amplification platform for "sample-to-answer" diagnosis of multiplexed plant pathogens within 30 min. This portable system consists of a polymeric MN patch for rapid nucleic acid extraction within a minute and a 3D-printed smartphone imaging device for loop-mediated isothermal amplification (LAMP) reaction and detection. We expanded the extraction of the MN technology for DNA targets as in the previous study (ACS Nano, 2019, 13, 6540-6549) to more fragile RNA biomarkers, evaluated the storability of the extracted nucleic acid samples on MN surfaces, and developed a smartphone-based LAMP amplification and fluorescent reader device that can quantify four LAMP reactions on the same chip.

View Article and Find Full Text PDF

Aim: Validate the Roche, MagNAPure96 (MP96) nucleic acid extraction platform for Seegene Anyplex II HPV28 (Anyplex28) detection of Human Papillomavirus.

Methods And Results: Comparisons were made for Anyplex28 genotyping from 115 cervical samples extracted on the Hamilton, STARlet and the MP96. Two DNA concentrations were used for the MP96, one matched for sample input to the STARlet and another 5× concentration (laboratory standard).

View Article and Find Full Text PDF