98%
921
2 minutes
20
Background: Primary stability following implant placement is essential for osseointegration and is affected by both implant design and bone density. The aim of this study was to compare the relationships between torque-time curves and implant designs in a poor bone quality model.
Methods: Nine implant designs, with five implants in each category, were compared. A total of 90 implants (Straumann: Standard RN, Bone Level RC, Tapered Effect RN; Nobel Biocare: Brånemark MKIII, MKIV) were placed in type IV artificial bone. Torque-time curves of insertion and removal were recorded at the rate of 1000 samples/s by a torque analyzer.
Results: The torque-time curves were divided into initial, parallel, tapered, and platform areas. The mean torque rise rate of the parallel area was smallest at 0.36 N · cm/s, with a significant difference from those of the other areas (p < 0.05). Values of 2.14, 2.33, and 2.65 N · cm/s were obtained for the initial, tapered, and platform areas, respectively. The removal torque for six of the implant designs (Bone Level RC 8, 10, and 12 mm; Tapered Effect RN 10 mm; Brånemark MKIII 10 mm, MKIV 10 mm) was significantly smaller than the corresponding insertion torque (p < 0.05). However, the removal torque for ST6, 8, and 10 was almost the same as or slightly greater than the corresponding insertion torque.
Conclusions: The insertion torque-time curves and design features of the implants were accurately transferred. Increasing implant taper angle appeared to increase the torque rate. Torque was mainly generated from the superior surface to the valley of the thread and the inferior and axial surfaces of the platform, while the inferior and axial surfaces of the thread did not significantly affect torque generation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5005779 | PMC |
http://dx.doi.org/10.1186/s40729-015-0024-0 | DOI Listing |
J Dent Sci
July 2025
Tokyo Clinic, Matsumoto Dental University, 1040061, Tokyo, Japan.
Background/purpose: This study examined the effect of insertion load on implant primary stability by evaluating the insertion torque and insertion time in various implant designs.
Materials And Methods: Four implant designs were tested, including one cylindrical implant standard (S), two hybrid implants tapered effect (TE) and bone level (BL), and one conical implant bone level tapered (BLT). Polyurethane bone models of the maxillary posterior region were used.
Clin Biomech (Bristol)
October 2024
Biomedical Engineering Doctorate Program, Boise State University, Boise, ID, USA. Electronic address:
Background: Strength and neuromuscular decrements following knee musculoskeletal injury may accelerate knee osteoarthritis development. This study assessed isometric knee extensor and flexor strength and steadiness between individuals with knee injury, i.e.
View Article and Find Full Text PDFSleep Sci
December 2023
Neuromuscular Research Lab, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada, Dafundo, Portugal.
The impact of sleep deprivation on the physiological determinants of explosive torque production remains poorly understood. We aimed at determining the acute effects of 24 hours of sleep deprivation on the sequential rate of torque development (RTD) obtained during plantar flexion through maximum voluntary isometric contraction (MVIC). The study included 14 healthy-young adults (8 men and 6 women).
View Article and Find Full Text PDFClin Biomech (Bristol)
October 2023
Department of Exercise Sciences, Brigham Young University, Provo, UT, USA.
Background: Individuals with chronic ankle instability have decreased peak torque during maximum voluntary contraction in ankle evertors/invertors, and hip abductors. However, it is unclear whether individuals with chronic ankle instability and/or copers demonstrate decreased rate of torque development in ankle evertors/invertors, and hip abductors.
Methods: 54 university-aged participants (18 chronic ankle instability, 18 copers, and 18 controls) performed three maximal isometric contractions for ankle evertors and invertors, and hip abductors.
J Hum Kinet
April 2022
Neuromuscular Research Lab, Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada, Dafundo, Portugal.
Exploring acute neuromuscular fatigue induced by different modalities of resistance exercise would help understand the adaptation subsequent to specific training programs. Therefore, we investigated the acute impact of high-intensity and low-intensity blood flow-restricted resistance exercise on the development of explosive torque throughout the torque-time curve. Seventeen healthy, young participants were included in a randomized, counterbalanced within-subjects design study, in which participants underwent two experimental conditions, separated by a 1-wk period.
View Article and Find Full Text PDF