98%
921
2 minutes
20
The acquisition of reliable kinetic parameters for the characterization of biomolecular interactions is an important component of the drug discovery and development process. While several benchmark studies have explored the variability of kinetic rate constants obtained from multiple laboratories and biosensors, a direct comparison of these instruments' performance has not been undertaken, and systematic factors contributing to data variability from these systems have not been discussed. To address these questions, a panel of ten high-affinity monoclonal antibodies was simultaneously evaluated for their binding kinetics against the same antigen on four biosensor platforms: GE Healthcare's Biacore T100, Bio-Rad's ProteOn XPR36, ForteBio's Octet RED384, and Wasatch Microfluidics's IBIS MX96. We compared the strengths and weaknesses of these systems and found that despite certain inherent systematic limitations in instrumentation, the rank orders of both the association and dissociation rate constants were highly correlated between these instruments. Our results also revealed a trade-off between data reliability and sample throughput. Biacore T100, followed by ProteOn XPR36, exhibited excellent data quality and consistency, whereas Octet RED384 and IBIS MX96 demonstrated high flexibility and throughput with compromises in data accuracy and reproducibility. Our results support the need for a "fit-for-purpose" approach in instrument selection for biosensor studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2016.06.024 | DOI Listing |
Biochim Biophys Acta Gen Subj
September 2025
Department of Biotechnology, Faculty of Applied Science, King Mongkut University of Technology North Bangkok, Bangkok 10800, Thailand; Food and Agro-Industrial Research Center, King Mongkut's University of Technology North Bangkok, Bangkok 10800, Thailand,. Electronic address:
In modern drug discovery, there is a pressing need for rapid, cost-effective, and accessible methods to evaluate the biological activities of newly synthesized compounds. Traditional kinase assay platforms are often labor-intensive, time-consuming, and require specialized equipment or expertise. To address these limitations, we developed and validated a convenient in vitro kinase assay based on a recombinant biosensor, Picchu-B, constructed using a bacterial expression system.
View Article and Find Full Text PDFJ Biomater Sci Polym Ed
September 2025
Department of Bioengineering, Faculty of Chemical and Metallurgical Engineering, Yildiz Technical University, Turkey.
Biodegradable biosensors represent a transformative advancement in sustainable sensing technology, offering an environmentally friendly and biocompatible alternative to traditional sensors. This review examines recent advancements, material innovations, degradation mechanisms, and application areas of biodegradable biosensors within the biomedical and environmental sectors. Natural and synthetic biodegradable polymers, such as chitosan, silk fibroin, alginate, PLA, PLGA, and PVA, are assessed for their functional contributions to sensing platforms.
View Article and Find Full Text PDFACS Synth Biol
September 2025
ARC Centre of Excellence in Synthetic Biology, Queensland University of Technology, Brisbane, QLD 4000, Australia.
Fluorescent proteins (FPs) are commonly used as reporters to examine intracellular genetic, molecular, and biochemical status. Flow cytometry is a powerful technique for accurate quantification of single-cell fluorescent levels. Here, we characterize green, red, and blue FPs for use in yeast .
View Article and Find Full Text PDFMikrochim Acta
September 2025
Faculty of Science, Shenyang University of Chemical Technology, Shenyang, 110142, China.
A sensitive electrochemical glucose biosensor using ZrO₂@CNTs nanocomposite was developed for real-time metabolism monitoring for athletes. The nanocomposite was prepared by a simple ultrasound-assisted technique, and the glucose oxidase (GOx) was covalently immobilized to improve the biorecognition ability. CNTs treated with acid served as a highly conductive framework, and ZrO₂ nanoparticles can provide structural stability and catalytic performance, thus showing synergistic enhancement of electron transfer kinetics and enzyme loading capacity.
View Article and Find Full Text PDFVirology
September 2025
Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science and Technology, Xinjiang University, Urumqi, Xinjiang, China. Electronic address:
Colloidal gold technology has revolutionized viral diagnostics through its rapid, cost-effective, and user-friendly applications, particularly in point-of-care testing (POCT). This review synthesizes recent advancements, focusing on its role in detecting respiratory viruses, hepatitis viruses, and emerging pathogens. The technology leverages the unique optical and physicochemical properties of gold nanoparticles (AuNPs), including localized surface plasmon resonance (LSPR) and high surface-to-volume ratios, to achieve rapid antigen-antibody recognition with visual readouts within 15 min.
View Article and Find Full Text PDF