Article Abstract

Objectives: Our aim was to assess image quality and radiation dose of low-voltage high-pitch computed tomography angiography of the infrarenal aorta and lower extremities and evaluate the efficacy of test injection technique using a monitoring scan at knee level.

Methods: A total of 60 patients with suspected peripheral arterial disease were divided into 2 groups: group 1 (30 patients, 80 kVp, high pitch [3.2], and hybrid iterative reconstruction [sinogram-affirmed iterative reconstruction]) and group 2 (30 patients, 120 kVp, low pitch [1.0], and filtered back projection reconstruction). The test injection technique at knee level was used to determine the scan delay time in group 1. The image quality and radiation exposure were compared.

Results: There were significant differences between the 2 groups in mean (SD) arterial attenuation (80 vs 120 kVp: 507.78 [103.01] vs 317.54 [62.03] Hounsfield units, P < 0.001), mean (SD) signal-to-noise ratio (51.04 [20.29] vs 34.66 [9.94], P < 0.001), and contrast-to-noise ratio (44.83 [17.93] vs 28.26 [9.60], P < 0.001). No difference in subjective image quality was found between the 2 groups (all P > 0.05). The imaging time was significantly shorter in group 1 (2.70 [0.11] vs 14.65 [0.90s], P < 0.001). The mean (SD) effective dose was significantly lower in the 80 kVp group (0.76 [0.06] vs 4.29 [0.63] mSv, P < 0.001).

Conclusions: The 80-kVp high-pitch computed tomography angiography of the lower limbs using sinogram-affirmed iterative reconstruction yields reduction of radiation exposure as well as obtains acceptable image quality if acquisition protocols are used in conjunction with the test injection technique using monitoring scan at knee level to determine the delay time.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RCT.0000000000000365DOI Listing

Publication Analysis

Top Keywords

image quality
20
test injection
16
tomography angiography
12
iterative reconstruction
12
monitoring scan
12
scan knee
12
knee level
12
injection technique
12
low-voltage high-pitch
8
angiography infrarenal
8

Similar Publications

Objective: To improve B field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array.

Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation.

View Article and Find Full Text PDF

The need to enhance the quality of life and functionality of patients with a number of diseases, such as congenital abnormalities, traumas, and gender incongruence, has contributed to a significant development in the field of male genital reconstructive surgery. This article highlights the roots of penile reconstructive surgeries over history, emphasizing innovative achievements that have shaped modern practices. Critical advancements that have improved surgical accuracy and post-operative care are examined, including new imaging modalities, penile prosthesis implantation, and complete phallic reconstruction.

View Article and Find Full Text PDF

In-line multi-wavelength non-destructive pharma quality monitoring with ultrabroadband carbon nanotubes photo-thermoelectric imaging scanners.

Light Sci Appl

September 2025

Department of Electrical, Electronic, and Communication Engineering, Faculty of Science and Engineering, Chuo University, 1-13-27 Kasuga, Bunkyo-ku, Tokyo, 112-8551, Japan.

While non-destructive in-line monitoring at manufacturing sites is essential for safe distribution cycles of pharmaceuticals, efforts are still insufficient to develop analytical systems for detailed dynamic visualisation of foreign substances and material composition in target pills. Although spectroscopies, expected towards pharma testing, have faced technical challenges in in-line setups for bulky equipment housing, this work demonstrates compact dynamic photo-monitoring systems by selectively extracting informative irradiation-wavelengths from comprehensive optical references of target pills. This work develops a non-destructive in-line dynamic inspection system for pharma agent pills with carbon nanotube (CNT) photo-thermoelectric imagers and the associated ultrabroadband sub-terahertz (THz)-infrared (IR) multi-wavelength monitoring.

View Article and Find Full Text PDF

Background And Objective: While whole-gland therapies for localized prostate cancer (PCa) offer excellent oncological outcomes, these can impact patients' quality of life (QoL) through serious side effects. Focal therapy using high-intensity focused ultrasound (HIFU) has emerged as a less invasive alternative to preserve QoL. However, data on the psychological impact of HIFU remain rare.

View Article and Find Full Text PDF

Background: Hounsfield units (HU) on computed tomography (CT) are strongly correlated with bone mineral density (BMD) and may aid in osteoporosis screening. However, there is no standardized method for assessing bone density in displaced femoral head fractures. This study aimed to measure HU values in the femoral head using preoperative post-fracture CT images of patients with intertrochanteric femoral fractures and investigate whether it correlated with BMD measured by dual-energy X-ray absorptiometry (DXA).

View Article and Find Full Text PDF