Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Although a smartphone could be used for a urine reagent strip test, few studies have reported on the reliability of the test in a clinical setting. The objective of our study was to access the smartphone-based urine reagent strip test in the clinical emergency department (ED).

Materials And Methods: We developed a smartphone-based urine reagent strip reader for a rapid and accurate screening of leukocyte esterase (LE) and nitrite (NIT) in urine. The developed reader was evaluated with the clinical urine samples (n = 81). The detection performance of the reader for LE and NIT was evaluated to assess reliability of the reader; turnaround times (TATs) for analysis and the time for the entire study procedure were also calculated to assess the efficiency of the reader. A photometric analyzer (model US-3100R Plus(®); Eiken Chemical, Ltd., Tokyo, Japan) was used as a reference.

Results: The proposed reader showed high accuracy (85.2% for LE and 97.5% for NIT), exhibiting close agreement with the true values (κ = 0.903 for LE; κ = 1.000 for NIT). The reader also exhibited a lower median TAT for analysis than the photometric analyzer (3.0 min versus 33.0 min; p < 0.001). This reduction of TAT in the reader was even more evident considering the required time for delivery of urine samples for the photometric analyzer (3.0 min versus 62.0 min; p < 0.001).

Conclusions: Our results demonstrated the clinical capability of a smartphone-based urine reagent strip test, and this reader is expected to enable a more rapid and reliable colorimetric test for screening of LE and NIT at the clinical setting and the point of care.

Download full-text PDF

Source
http://dx.doi.org/10.1089/tmj.2015.0153DOI Listing

Publication Analysis

Top Keywords

urine reagent
16
reagent strip
16
smartphone-based urine
12
strip test
12
emergency department
8
test clinical
8
photometric analyzer
8
reader
7
urine
5
reagent
4

Similar Publications

Accuracy of leukocyte esterase and nitrite tests for diagnosing bacteriuria in older adults: A systematic review and meta-analysis.

Clin Microbiol Infect

September 2025

Institute for Primary Health Care Research Jordi Gol i Gurina (IDIAPJGol), Barcelona, Spain; CIBER de Enfermedades Infecciosas, Instituto de Salud Carlos III, Madrid, Spain; Research Unit for General Practice, Department of Public Health, University of Southern Denmark, Odense-Aabenraa, Denmark; Stu

Background: Urine dipsticks are commonly used for the diagnosis of bacteriuria and/or urinary tract infections (UTIs).

Objectives: To perform a systematic review and meta-analysis to evaluate the accuracy of positive leukocyte esterase and/or nitrite results from dipsticks (index test) for diagnosing bacteriuria in older individuals, using urine culture as the reference standard.

Data Sources: MEDLINE (Pubmed), EMBASE, and Cochrane Database of Systematic Reviews from the inception date up to April 2025.

View Article and Find Full Text PDF

Weight-independent amelioration of adipokine profile by enavogliflozin, a selective SGLT2 inhibitor, in patients with type 2 diabetes.

Cardiovasc Diabetol

August 2025

Division of Endocrinology and Metabolism, Department of Internal Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Republic of Korea.

Background And Objective: The metabolic benefits of sodium-glucose co-transporter 2 inhibitors in clinical application are well established; however, there is dearth of knowledge on their impact on adipokine regulation. This study investigated the effect of enavogliflozin on adiponectin and leptin in patients with type 2 diabetes.

Methods: This secondary analysis of a phase III randomized, double-blind, placebo-controlled trial evaluated changes in serum adiponectin and leptin over 24 weeks.

View Article and Find Full Text PDF

Coronavirus Disease 2019 (COVID-19), caused by SARS-CoV-2, has posed a significant global public health challenge, with long-term sequelae such as post-COVID-19 syndrome continuing to burden health systems. Tobacco use, a major preventable cause of morbidity and mortality, impairs the immune response and exacerbates respiratory diseases, including COVID-19. Passive smoking, an important but often overlooked public health problem, exposes non-smokers to harmful health risks and may contribute to worse outcomes in respiratory disease.

View Article and Find Full Text PDF

Evaluation of coadministration schedules of rA1M for kidney protection after administration of 177Lu-octreotide.

Radiat Prot Dosimetry

August 2025

Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, SE-413 45 Gothenburg, Sweden.

Late radiation-induced kidney toxicity limits molecular radionuclide therapy using radiopharmaceuticals such as 177Lu-octreotate and 177Lu-octreotide. Better kidney protection would allow higher amounts of radiopharmaceutical to be administered. Coadministration of recombinant human alpha-1-microglobulin (rA1M) has been suggested to protect kidneys from exposure from 177Lu-octreotate.

View Article and Find Full Text PDF

Background: Liquid chromatography-mass spectrometry (LC-MS), widely used in metabolomics, is often limited by low ionization efficiency and ion suppression, which reduce overall metabolite detectability and quantification accuracy. To address these challenges, chemical isotope labeling (CIL) LC-MS has emerged as a powerful approach, offering high sensitivity, accurate quantification, and broad metabolome coverage. This method enables comprehensive profiling by targeting multiple submetabolomes.

View Article and Find Full Text PDF