Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Two-dimensional blood velocity estimation has shown potential to solve the angle-dependency of conventional ultrasound flow imaging. Clutter filtering, however, remains a major challenge for large beam-to-flow angles, leading to signal drop-outs and corrupted velocity estimates. This work presents and evaluates a compounding speckle tracking (ST) algorithm to obtain robust angle-independent 2-D blood velocity estimates for all beam-to-flow angles. A dual-angle plane wave imaging setup with full parallel receive beamforming is utilized to achieve high-frame-rate speckle tracking estimates from two scan angles, which may be compounded to obtain velocity estimates of increased robustness. The acquisition also allows direct comparison with vector Doppler (VD) imaging. Absolute velocity bias and root-mean-square (RMS) error of the compounding ST estimations were investigated using simulations of a rotating flow phantom with low velocities ranging from 0 to 20 cm/s. In a challenging region where the estimates were influenced by clutter filtering, the bias and RMS error for the compounding ST estimates were 11% and 2 cm/s, a significant reduction compared with conventional single-angle ST (22% and 4 cm/s) and VD (36% and 6 cm/s). The method was also tested in vivo for vascular and neonatal cardiac imaging. In a carotid artery bifurcation, the obtained blood velocity estimates showed that the compounded ST method was less influenced by clutter filtering than conventional ST and VD methods. In the cardiac case, it was observed that ST velocity estimation is more affected by low signal-to-noise (SNR) than VD. However, with sufficient SNR the in vivo results indicated that a more robust angle-independent blood velocity estimator is obtained using compounded speckle tracking compared with conventional ST and VD methods.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2015.007108DOI Listing

Publication Analysis

Top Keywords

blood velocity
20
velocity estimates
16
robust angle-independent
12
velocity estimation
12
clutter filtering
12
speckle tracking
12
velocity
9
angle-independent blood
8
dual-angle plane
8
plane wave
8

Similar Publications

Optimized FDA Blood Pump: A Case Study in System-Level Customized Ventricular Assist Device Designs.

Ann Biomed Eng

September 2025

Department of Mechanical Engineering, Koc University, Rumeli Feneri Campus, Sarıyer, 34450, Istanbul, Turkey.

Purpose: The design and development of ventricular assist devices have heavily relied on computational tools, particularly computational fluid dynamics (CFD), since the early 2000s. However, traditional CFD-based optimization requires costly trial-and-error approaches involving multiple design cycles. This study aims to propose a more efficient VAD design and optimization framework that overcomes these limitations.

View Article and Find Full Text PDF

Purpose: This study explored the acute physiological effects of different eccentric tempos, explosive speed (EXP), volitional speed, and 4-second tempo during 5 sets of velocity-based squat training.

Methods: Twelve healthy males performed parallel squats under 3 eccentric conditions using a randomized crossover design. Each session included 5 sets at a relative load, initiated with a concentric mean velocity of 0.

View Article and Find Full Text PDF

Airway obstruction and gender affect arterial stiffness in children with cystic fibrosis.

Turk J Pediatr

September 2025

Department of Cardiorespiratory Physiotherapy and Rehabilitation, Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Türkiye.

Background: Vascular changes are observed in children with cystic fibrosis (cwCF), and gender-specific differences may impact arterial stiffness. We aimed to compare arterial stiffness and clinical parameters based on gender in cwCF and to determine the factors affecting arterial stiffness in cwCF.

Methods: Fifty-eight cwCF were included.

View Article and Find Full Text PDF

Objectives: To evaluate the predictive role of carotid stiffening, quantified using ultrafast pulse wave velocity (ufPWV), for assessing cardiovascular risk in young populations with no or elevated cardiovascular risk factors (CVRFs).

Materials And Methods: This study enrolled 180 young, apparently healthy individuals who underwent ufPWV measurements. They were classified into three groups: the CVRF-free group (n = 60), comprising current non-smokers with untreated blood pressure < 140/90 mmHg, fasting blood glucose (FBG) < 7.

View Article and Find Full Text PDF

Cerebral autoregulation in orthostatic hypotension and falls among older adults: a community-based exploratory study.

Clin Auton Res

September 2025

Faculty of Medicine, Department of Medicine, Ageing and Age-Associated Disorders Research Group, Division of Geriatric Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia.

Background: Orthostatic hypotension (OH) is prevalent in older adults and is often associated with falls. However, the presence or absence of symptoms in OH may be mediated by cerebral autoregulation, which helps maintain cerebral perfusion during blood pressure fluctuations.

Methods: We recruited 40 older adults (aged ≥ 55 years) from the Malaysian Elders Longitudinal Research (MELoR) cohort.

View Article and Find Full Text PDF