Iterative CT shading correction with no prior information.

Phys Med Biol

Sir Run Run Shaw Hospital, Zhejiang University School of Medicine; Institute of Translational Medicine, Zhejiang University, Hangzhou, Zhejiang, 310016, People's Republic of China.

Published: November 2015


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Shading artifacts in CT images are caused by scatter contamination, beam-hardening effect and other non-ideal imaging conditions. The purpose of this study is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT images (e.g. cone-beam CT, low-kVp CT) without relying on prior information. The method is based on the general knowledge of the relatively uniform CT number distribution in one tissue component. The CT image is first segmented to construct a template image where each structure is filled with the same CT number of a specific tissue type. Then, by subtracting the ideal template from the CT image, the residual image from various error sources are generated. Since forward projection is an integration process, non-continuous shading artifacts in the image become continuous signals in a line integral. Thus, the residual image is forward projected and its line integral is low-pass filtered in order to estimate the error that causes shading artifacts. A compensation map is reconstructed from the filtered line integral error using a standard FDK algorithm and added back to the original image for shading correction. As the segmented image does not accurately depict a shaded CT image, the proposed scheme is iterated until the variation of the residual image is minimized. The proposed method is evaluated using cone-beam CT images of a Catphan©600 phantom and a pelvis patient, and low-kVp CT angiography images for carotid artery assessment. Compared with the CT image without correction, the proposed method reduces the overall CT number error from over 200 HU to be less than 30 HU and increases the spatial uniformity by a factor of 1.5. Low-contrast object is faithfully retained after the proposed correction. An effective iterative algorithm for shading correction in CT imaging is proposed that is only assisted by general anatomical information without relying on prior knowledge. The proposed method is thus practical and attractive as a general solution to CT shading correction.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/60/21/8437DOI Listing

Publication Analysis

Top Keywords

shading correction
16
shading artifacts
16
residual image
12
proposed method
12
image
11
artifacts images
8
relying prior
8
template image
8
correction
7
shading
7

Similar Publications

Multiband Fast Spin Echo on portable low-field systems.

Magn Reson Med

August 2025

School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.

Purpose: To improve the SNR efficiency of Fast Spin Echo (FSE) using RF-encoded multiband imaging and to develop techniques that correct artifacts from non-Carr-Purcell-Meiboom-Gill (CPMG) magnetization arising from system imperfections.

Methods: Optimal refocusing pulse band phase modulations that satisfy the CPMG condition were calculated for different multiband factors. Fast recovery was used to enhance T2 contrast.

View Article and Find Full Text PDF

Complementary and alternative therapies (CAT) is an umbrella term applied to a diverse set of approaches, with high interest among persons with Parkinson's disease. However, scientific community regards evidence-based medicine as the only acceptable, creating a black and white dichotomy, which is neither epistemologically correct nor workable in daily practice. CAT are heterogeneous, and the label is dynamic as new scientific insights might accrue.

View Article and Find Full Text PDF

Purpose: To assess the impact of resin cement color and the thickness of monolithic CAD/CAM materials on the final color of the fixed dental restoration.

Materials And Methods: Four high translucent monolithic CAD-CAM materials in shade A2, including lithium disilicate glass-ceramic (IPS e.max CAD, IP), monolithic zirconia (Ceramill Zolid HT+, CZ), two zirconia-reinforced lithium silicate ceramics (VITA Suprinity, VS, and Celtra Duo, CD) were prepared as rectangular specimens measuring 12 × 14 mm in two thicknesses (0.

View Article and Find Full Text PDF

Background: Due to the expanding population aging phenomenon, public spaces must be redesigned architecturally to make them accessible to the elderly. Motivating people to engage in physical activity is crucial because outdoor exercise positively impacts seniors' well-being. Outdoor gyms, which serve as meeting spots, places to work out, and locations for daily walks, play a significant role in this context.

View Article and Find Full Text PDF

The aim of this study was to evaluate the impact of various polishing methods on the color stability of compomer and composite resin restorations used in anterior restorations within pediatric dentistry. One hundred and twenty disc-shaped specimens (8 mm diameter x 4 mm thickness) were prepared from A2 shade compomer and nanohybrid composite resin to assess color stability in four different polishing systems. Sixty specimens from each material were randomly distributed into five groups (n = 12) according to the polishing method used.

View Article and Find Full Text PDF