Frequency-change in DPOAE evoked by 1 s/octave sweeping primaries in newborns and adults.

Hear Res

Speech-Language-Hearing Sciences, Graduate School and University Center, City University of New York, 365 Fifth Avenue, NY 10016, United States. Electronic address:

Published: October 2015


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Distortion product otoacoustic emissions (DPOAE) in newborns and adults were evoked by sweeping primaries up and down in frequency at 1 s/octave. Sweeping up and down in frequency resulted in changes in the amplitude vs. frequency functions of the composite DPOAE and its two major components. In addition, DPOAE component phases differed slightly between the up- and down-swept conditions. The changes in amplitude vs. frequency functions were quantified using a covariate correlation technique, yielding single-valued estimates of the magnitude of the frequency changes. Separate analyses were performed for the entire DPOAE frequency range and split into low and high frequency ranges. There were consistent changes in newborn and adult composite DPOAEs and reflection components, but not generator components. Adults had significant frequency changes in the composite DPOAE for all frequency ranges and in the reflection component for the entire frequency range. Newborns had significant frequency change in the reflection component for all frequency ranges. Differences in frequency change between adults and newborns may stem from developmental changes in cochlear processing. Alignment of the component phase differences between the up- and down-swept conditions resulted in elimination of frequency-change in reconstructed composite DPOAEs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.heares.2015.08.012DOI Listing

Publication Analysis

Top Keywords

frequency
13
frequency changes
12
frequency ranges
12
1 s/octave sweeping
8
sweeping primaries
8
newborns adults
8
changes amplitude
8
amplitude frequency
8
frequency functions
8
composite dpoae
8

Similar Publications

The Guide for the Care and Use of Laboratory Animals provides recommendations on sanitation frequencies for rodent caging equipment; however, it allows for performance standards to be used when extending this frequency for individually ventilated cage (IVC) caging. Our institution wanted to reexamine our current standards of care for mouse IVC caging, which includes a 14-d cage bottom and bedding change as well as the use of corncob bedding. This was driven by desire to reduce the stress to mice associated with cage change, and by recent literature showing a potential improved absorbency and multiple health and welfare benefits of paper pulp cellulose bedding products.

View Article and Find Full Text PDF

Background: Previous studies have suggested that the associations between ambient air pollution and atherosclerotic cardiovascular diseases (ASCVD) differ by genotype. A genome-wide approach provides a more comprehensive understanding of this relationship on a genomic scale.

Methods: Using data from ≈300 000 UK Biobank participants, we conducted a genome-wide interaction analysis on 10 745 802 variants.

View Article and Find Full Text PDF

Background: Cardio-kidney-metabolic (CKM) disease represents a significant public health challenge. While proteomics-based risk scores (ProtRS) enhance cardiovascular risk prediction, their utility in improving risk prediction for a composite CKM outcome beyond traditional risk factors remains unknown.

Methods: We analyzed 23 815 UK Biobank participants without baseline CKM disease, defined by -Tenth Revision codes as cardiovascular disease (coronary artery disease, heart failure, stroke, peripheral arterial disease, atrial fibrillation/flutter), kidney disease (chronic kidney disease or end-stage renal disease), or metabolic disease (type 2 diabetes or obesity).

View Article and Find Full Text PDF

Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).

Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.

View Article and Find Full Text PDF