Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The maximum thickness permissible within the single-scattering approximation for the determination of the structure of perfectly ordered protein microcrystals by transmission electron diffraction is estimated for tetragonal hen-egg lysozyme protein crystals using several approaches. Multislice simulations are performed for many diffraction conditions and beam energies to determine the validity domain of the required single-scattering approximation and hence the limit on crystal thickness. The effects of erroneous experimental structure factor amplitudes on the charge density map for lysozyme are noted and their threshold limits calculated. The maximum thickness of lysozyme permissible under the single-scattering approximation is also estimated using R-factor analysis. Successful reconstruction of density maps is found to result mainly from the use of the phase information provided by modeling based on the protein data base through molecular replacement (MR), which dominates the effect of poor quality electron diffraction data at thicknesses larger than about 200 Å. For perfectly ordered protein nanocrystals, a maximum thickness of about 1000 Å is predicted at 200 keV if MR can be used, using R-factor analysis performed over a subset of the simulated diffracted beams. The effects of crystal bending, mosaicity (which has recently been directly imaged by cryo-EM) and secondary scattering are discussed. Structure-independent tests for single-scattering and new microfluidic methods for growing and sorting nanocrystals by size are reviewed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2014.08.013DOI Listing

Publication Analysis

Top Keywords

maximum thickness
12
single-scattering approximation
12
protein nanocrystals
8
permissible single-scattering
8
perfectly ordered
8
ordered protein
8
electron diffraction
8
r-factor analysis
8
solving protein
4
nanocrystals cryo-em
4

Similar Publications

Purpose: To evaluate the effect of die spacer thickness on the fit and load to failure of cantilever resin-bonded fixed dental prostheses (RBFDPs).

Methods: Two identical maxillary RBFDPs with a retainer on the canine were designed to replace a lateral incisor. One design involved a closely fitting retainer with no die spacer (NDS), and the other included an 80-µm die spacer (DS).

View Article and Find Full Text PDF

Spatially and temporally controlled drug delivery is an important field to address the limitations of conventional pharmaceutical administration. While many effective controlled drug delivery systems exist, the repertoire of systems that additionally present a beneficial mechanical environment to cells remains scarce. To address this, a comprehensive release study of fluorescein as a model drug, and the corticosteroid dexamethasone, from poly(-isopropylacrylamide)/polypyrrole (pNIPAM/PPy) conducting polymer hydrogels is presented within this study.

View Article and Find Full Text PDF

Background: Ear canker in domestic rabbits is caused by infestations of non-burrowing parasitic mites, Psoroptes spp., but the specific species responsible for these infestations remains unclear. This study reports the clinical signs and performs the molecular characterization and phylogenetic analysis of Psoroptes ovis isolated from the ear canal of a domestic rabbit in South India.

View Article and Find Full Text PDF

Objective This research investigated the application of real-time, three-dimensional speckle tracking imaging (RT-3D-STI) to evaluate left atrial (LA) function in individuals suffering from hypertensive heart disease (HHD) and heart failure with preserved ejection fraction (HFpEF).Material and methods This retrospective study included 100 patients with HHD and HFpEF hospitalized from August 2023to June 2024 (HFpEF group). 100 healthy individuals undergoing physical examinations comprised the control group.

View Article and Find Full Text PDF

Background: Optical coherence tomography (OCT) with artificial intelligence (AI) has been developed.

Aims: The study aimed to evaluate the differences between AI-quantified and visual assessments.

Methods: Patients scheduled for OCT-guided percutaneous coronary intervention between September 2021 and October 2022 were included.

View Article and Find Full Text PDF