Article Abstract

Electrocardiographic imaging (ECG imaging) is a method to depict electrophysiological processes in the heart. It is an emerging technology with the potential of making the therapy of cardiac arrhythmia less invasive, less expensive, and more precise. A major challenge for integrating the method into clinical workflow is the seamless and correct identification and localization of electrodes on the thorax and their assignment to recorded channels. This work proposes a camera-based system, which can localize all electrode positions at once and to an accuracy of approximately 1 ± 1 mm. A system for automatic identification of individual electrodes is implemented that overcomes the need of manual annotation. For this purpose, a system of markers is suggested, which facilitates a precise localization to subpixel accuracy and robust identification using an error-correcting code. The accuracy of the presented system in identifying and localizing electrodes is validated in a phantom study. Its overall capability is demonstrated in a clinical scenario.

Download full-text PDF

Source
http://dx.doi.org/10.1515/bmt-2014-0018DOI Listing

Publication Analysis

Top Keywords

electrode positions
8
electrocardiographic imaging
8
automatic camera-based
4
identification
4
camera-based identification
4
identification 3-d
4
3-d reconstruction
4
reconstruction electrode
4
positions electrocardiographic
4
imaging electrocardiographic
4

Similar Publications

Operando Evaluation of the Electrochemically Active Area in a Solid Oxide Fuel Cell Porous Electrode by Micro X-ray Absorption Spectroscopy.

J Phys Chem Lett

September 2025

Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan.

An operando X-ray absorption spectroscopic technique, which enables us to measure X-ray absorption spectra with a position resolution of submicrometers at increased temperatures while controlling atmospheres and passing an electrical current through the specimen, was developed. By applying this technique, the electrochemically active area in a porous LaSrCoO electrode for a solid oxide fuel cell (SOFC) was experimentally and directly evaluated for the first time. The characteristic length of the active area was approximately 1 μm from the electrode-electrolyte interface under a cathodic overpotential of 140 mV at 873 K under 10 bar of (O), although the investigated electrode was thicker than 50 μm.

View Article and Find Full Text PDF

The multi-user motor imagery brain-computer interface (BCI) is a new approach that uses information from multiple users to improve decision-making and social interaction. Although researchers have shown interest in this field, the current decoding methods are limited to basic approaches like linear averaging or feature integration. They ignored accurately assessing the coupling relationship features, which results in incomplete extraction of multi-source information.

View Article and Find Full Text PDF

The multi-channel synchronous stimulator, aimed at achieving efficient and precise neural regulation, typically utilizes a monolithic microelectrode array structure. However, this structure limits the flexibility of electrode placement and the expansion to a large number of nodes, particularly in discontinuous locations. To address this, this paper designs a distributed passive micro-magnetic stimulation (DP-μMS) neuro-regulation device with multi-brain region collaborative stimulation functionality.

View Article and Find Full Text PDF

Electroencephalography-based brain-computer interfaces have revolutionized the integration of neural signals with technological systems, offering transformative solutions across neuroscience, biomedical engineering, and clinical practice. This review systematically analyzes advancements in electroencephalography-based brain-computer interface architectures, emphasizing four pillars, namely signal acquisition, paradigm design, decoding algorithms, and diverse applications. The aim is to bridge the gap between technology and application and guide future research.

View Article and Find Full Text PDF

Hybrid pneumatic-hydraulic actuation for MRI-guided robotic stereotactic neurointervention.

Sci Adv

September 2025

Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200336, China.

Stereotactic neurointervention is a common procedure for biopsy, injection, ablation, and implantation of electrodes for deep brain stimulation. Guided by preoperative imaging, conventional approaches are mostly performed manually, lacking operation stability and interactive feedback. The intraoperative magnetic resonance imaging (MRI) guidance enables both structural and functional assessment during operation, permitting interactive adaptation to tissue deformation and avoidance of critical anatomical regions.