Article Abstract

Aim: Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period.

Methods And Results: We randomized 240 patients (age 74 ± 11 years, 67% male) with a high-grade AV block requiring >90% ventricular pacing and preserved baseline LVEF >50%, to receive pacing at the RVA (n = 120) or RVHS (n = 120). At 2 years, LVEF decreased in both the RVA (57 ± 9 to 55 ± 9%, P = 0.047) and the RVHS groups (56 ± 10 to 54 ± 10%, P = 0.0003). However, there was no significant difference in intra-patient change in LVEF between confirmed RVA (n = 85) and RVHS (n = 83) lead position (P = 0.43). There were no significant differences in heart failure hospitalization, mortality, the burden of atrial fibrillation, or plasma brain natriutetic peptide levels between the two groups. A significantly greater time was required to place the lead in the RVHS position (70 ± 25 vs. 56 ± 24 min, P < 0.0001) with longer fluoroscopy times (11 ± 7 vs. 5 ± 4 min, P < 0.0001).

Conclusion: In patients with a high-grade AV block and preserved LV function requiring a high percentage of ventricular pacing, RVHS pacing does not provide a protective effect on left ventricular function over RVA pacing in the first 2 years.

Protect-pace: ClinicalTrials.gov number NCT00461734.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurheartj/ehu304DOI Listing

Publication Analysis

Top Keywords

ventricular pacing
12
left ventricular
8
ventricular function
8
patients high-grade
8
atrioventricular block
8
pacing
8
rva pacing
8
rvhs pacing
8
high-grade block
8
ventricular
6

Similar Publications

Aims: There is a lack of data from randomized clinical trials comparing treatment outcomes between conduction system pacing (CSP) modalities and biventricular pacing (BVP) in symptomatic patients with refractory atrial fibrillation (AF) scheduled for atrioventricular node ablation (AVNA). The CONDUCT-AF investigates whether CSP is non-inferior to BVP in improving left ventricular ejection fraction (LVEF) and clinical outcomes in heart failure (HF) patients with symptomatic AF undergoing AVNA.

Methods: This study is an investigator-initiated, prospective, randomized, multicentre clinical trial conducted across 10 European centres, enrolling 82 patients with symptomatic AF, HF with reduced LVEF, and narrow QRS.

View Article and Find Full Text PDF

Background: A high burden of right ventricular pacing (RVP) increases the risk of hospitalization because of heart failure. Data on predictive factors for high burden of RVP in patients with permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) are limited.

Objective: This study aimed to identify predictors of high RVP burden in patients with current indications for PPI after TAVR.

View Article and Find Full Text PDF

Background: Leadless pacemakers (LPs) can reduce long-term complications compared with conventional devices. However, previous studies have primarily focused on single chamber right ventricular LPs.

Objective: This study aimed to evaluate the implantation, safety, and device performance characteristics in a first real-world European use of an active fixation atrial LP for either dual chamber or single chamber pacing.

View Article and Find Full Text PDF

Background: During the electrode screwing process in left bundle branch pacing (LBBP), the significance of the S wave in lead V6 remains elusive. Our study analyzes the change of the S wave in lead V6 under different patterns of capture and explores its mechanisms.

Methods: This study included 243 cases with criterion of selective LBBP (SLBBP), we performed continuous pacing technique and classified the electrophysiological characteristics observed during the screwing process into four patterns: left ventricular septal pacing (LVSP), non-selective LBBP (NSLBBP) in low output and in the lower output, selective LBBP.

View Article and Find Full Text PDF

Identifying the onset of the QRS complex is an important step for localizing the site of origin (SOO) of premature ventricular complexes (PVCs) and the exit site of Ventricular Tachycardia (VT). However, identifying the QRS onset is challenging due to signal noise, baseline wander, motion artifact, and muscle artifact. Furthermore, in VT, QRS onset detection is especially difficult due to the overlap with repolarization from the prior beat.

View Article and Find Full Text PDF