Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In modern ultrasound imaging devices, two-dimensional probes and electronic scanning allow volumetric imaging of anatomical structures. When dealing with the design of such complex 3-D ultrasound (US) systems, as the number of transducers and channels dramatically increases, new challenges concerning the integration of electronics and the implementation of smart micro-beamforming strategies arise. Hence, the possibility to predict the behavior of the whole system is mandatory. In this paper, we propose and describe an advanced simulation tool for ultrasound system modeling and simulation, which conjugates the US propagation and scattering, signal transduction, electronic signal conditioning, and beamforming in a single environment. In particular, we present the architecture and model of an existing 16-channel integrated receiver, which includes an amplification and micro-beamforming stage, and validate it by comparison with circuit simulations. The developed model is then used in conjunction with the transducer and US field models to perform a system simulation, aimed at estimating the performance of an example 3-D US imaging system that uses a capacitive micromachined ultrasonic transducer (CMUT) 2-D phased-array coupled to the modeled reception front-end. Results of point spread function (PSF) calculations, as well as synthetic imaging of a virtual phantom, show that this tool is actually able to model the complete US image reconstruction process, and that it could be used to quickly provide valuable system-level feedback for an optimized tuning of electronic design parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2014.6805693DOI Listing

Publication Analysis

Top Keywords

ultrasound imaging
8
imaging system
8
imaging
5
system
5
volumetric cmut-based
4
ultrasound
4
cmut-based ultrasound
4
system simulator
4
simulator integrated
4
integrated reception
4

Similar Publications

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

Background: This study aimed to investigate the gender-specific associations of skeletal muscle mass and fat mass with non-alcoholic fatty liver disease (NAFLD) and NAFLD-related liver fibrosis in two population-based studies.

Methods: Analyses were based on data from the MEGA (n = 238) and the MEIA study (n = 594) conducted between 2018 and 2023 in Augsburg, Germany. Bioelectrical impedance analysis was used to evaluate relative skeletal muscle mass (rSM) and SM index (SMI) as well as relative fat mass (rFM) and FM index (FMI); furthermore, the fat-to-muscle ratio was built.

View Article and Find Full Text PDF

Background: Disturbances in lipid metabolism are usually associated with hyperlipidemia, which is commonly observed in donkeys with inappetence or anorexia. The diagnostic utility of ultrasound measurements of croup fat thickness (CFT) and relative liver echogenicity for lipomobilization in donkeys with fasting-induced hyperlipidemia was investigated. A prospective observational control study involving 25 donkeys was conducted, and the animals were randomly assigned to a fasting group (FG, n = 20) and a control group (CG, n = 5).

View Article and Find Full Text PDF

Background: This study aimed to evaluate the impact of asthma severity on biventricular cardiac functions using tissue Doppler imaging (TDI), two-dimensional speckle tracking echocardiography (2D-STE), and three-dimensional speckle tracking echocardiography (3D-STE).

Methods: Sixty-three children with asthma, aged between 5 and 16 years, were enrolled in the study along with 63 matched controls. All participants underwent cardiac assessments, including TDI, 2D-STE, 3D-STE, conventional echocardiography, and pulmonary function testing with spirometry.

View Article and Find Full Text PDF

Background: Thyroid nodules (TNs) are frequent and often benign. Accurately differentiating between benign and malignant nodules is crucial for proper management. This research aims to use ultrasonography to examine TNs and identify possible risk factors in order to improve patient outcomes and diagnostic accuracy.

View Article and Find Full Text PDF