Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Previous studies demonstrated that individuals with subtype D HIV infection who had been infected for 2 or more years were frequently misclassified as assay positive using cross-sectional incidence assays. Samples from 510 subjects (212 subtype A, 298 subtype D) who were infected for 2.2 to 14.5 years (median 5.4 years) and were not virally suppressed were tested using an LAg-Avidity enzyme immunoassay (LAg-Avidity EIA), Bio-Rad Avidity assay, and BED capture enzyme immunoassay (BED-CEIA). The performance of these three assays was evaluated using various assay cutoff values [LAg-Avidity EIA: <1.0 OD-n and <2.0 OD-n; Bio-Rad Avidity assay: <40% avidity index (AI) and <80% AI; BED-CEIA: <0.8 OD-n]. The mean LAg-Avidity EIA result was higher for subtype A than D (4.54±0.95 vs. 3.86±1.26, p<0.001); the mean Bio-Rad Avidity assay result was higher for subtype A than D (88.9%±12.5% vs. 75.1±30.5, p<0.001); and the mean BED-CEIA result was similar for the two subtypes (2.2±1.2 OD-n for subtype A, 2.2±1.3 OD-n for subtype D, p<0.9). The frequency of misclassification was higher for individuals with subtype D infection compared to those with subtype A infection, using either the LAg-Avidity EIA with a cutoff of <2.0 OD-n or the Bio-Rad Avidity assay with cutoffs of <40% or <80% AI. No subtype-specific differences in assay performance were observed using the BED-CEIA. Sex and age were not significantly associated with misclassification by any assay. The LAg-Avidity EIA with a cutoff <1.0 OD-n had the lowest frequency of misclassification in this Ugandan population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3976571PMC
http://dx.doi.org/10.1089/aid.2013.0169DOI Listing

Publication Analysis

Top Keywords

enzyme immunoassay
12
bio-rad avidity
8
avidity assay
8
assay bed
8
bed capture
8
impact hiv
4
subtype
4
hiv subtype
4
subtype performance
4
performance limiting
4

Similar Publications

Global warming causes heat stress in livestock, impairing their health, welfare, and productivity. In bovines, chronic stress elevates cortisol levels; however, this response often goes undetected due to the lack of practical biomatrices for accurate assessment. Common biomatrices such as blood require repeated sampling that may affect measurement accuracy.

View Article and Find Full Text PDF

Purpose: To investigate the short-term impact of exposure to smoke from vegetation burns on ocular surface symptoms and signs.

Methods: Woody bushfuels were burnt in an enclosed room (Flammability Laboratory, University of Tasmania, Australia) to generate particulate matter and monitored in real time (Dust Trak II). Eighteen participants (aged 20-63 years, 8 males and 10 females) fitted with respirators were seated 1.

View Article and Find Full Text PDF

In the United States, the use of Food & Drug Administration (FDA)-licensed, approved, or cleared tests is required for infectious disease screening and determining the eligibility of deceased donors for all Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps). With the discontinuation of two manual enzyme-linked immunoassay (EIA) tests, automated Chemiluminescent Microparticle Immunoassay (CMIA) technology was introduced as the primary alternative. This study compares serologic reactivity rates between manual EIA and automated CMIA methods.

View Article and Find Full Text PDF

Directed Design of Anti-Idiotypic Nanobody with Antibacterial Activity against Foodborne and Its Innovative Application in Green Immunoassay.

ACS Synth Biol

September 2025

Jiangsu Key Laboratory for Food Quality and Safety, State Key Laboratory Cultivation Base of Ministry of Science and Technology, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.

Anti-idiotypic antibodies (Anti-Ids) possess the properties to mimic the structure and biological activity of an antigen, which can be utilized for preventing and monitoring hazards. In this study, Nb4Mutant6-Anti-Id, which mimics the structure and antibacterial activity of vancomycin, was designed based on phage display antibody library screening and mutagenesis technology. The affinity of Nb4Mutant6-Anti-Id for the coated antigens of Van-pAbs F(ab)2 and inactivated cells was 6.

View Article and Find Full Text PDF

A Versatile DNAzyme-Amplified Protease-Sensing Platform for Accurate Diagnosis of SARS-CoV-2 and Reliable Classification of Colorectal Cancer.

Angew Chem Int Ed Engl

September 2025

College of Chemistry and Molecular Sciences, Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430072, P.R. China.

Peptide-based biosensors are widely used for in vitro detection of protease activity but often suffer from the limited sensitivity, poor accuracy, and incompatibility with point-of-care testing (POCT) devices. Herein, we developed a versatile deoxyribozyme (DNAzyme)-amplified protease-sensing (DP) platform that integrates the positively charged oligopeptides with a negatively charged DNAzyme biocatalyst for highly-sensitive protease detection. The system leverages the electrostatic peptide-DNAzyme interactions to inhibit DNAzyme catalytic activity, which is reactivated upon the protease-triggered peptide hydrolysis, thus enabling an efficient signal amplification via the successive cleavage of DNAzyme substrate.

View Article and Find Full Text PDF