Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The purpose of this study was to determine the particulate concentration in a gelatin-based ultrasound phantom for lesion biopsy at 6 cm in depth to reduce visualization of the biopsy needle in the near field, simulating subcutaneous fat and tissue echogenicity, and maintain target lesion visualization.

Methods: Four gelatin-based phantoms with cornstarch at concentrations of 4, 8, 12, and 16 g/L and an anechoic gelatin target at 7 cm in depth were rated on a 5-point scale by readers for visibility of the target lesion, similarity of near-field to abdominal subcutaneous fat echogenicity, and visibility of a 22-gauge spinal needle in the phantom. A timed sonographically guided localization task was performed on the anechoic target by 4 radiology residents using the 22-gauge spinal needle. Results were analyzed by comparative statistical analysis.

Results: An increasing particulate concentration did not alter the similarity of near-field to abdominal subcutaneous fat echogenicity (P = .6) but did significantly reduce visibility of the anechoic target at a cornstarch concentration of 16 g/L (P = .04) and the 22-gauge needle at 12 g/L (P = .03). Decreased visualization of the needle or target lesion did not affect the time for needle localization of the anechoic target (P = .96).

Conclusions: The optimal ultrasound phantom cornstarch concentration was 12 g/L to reduce visualization of the spinal needle, simulating subcutaneous fat echogenicity while maintaining target lesion visualization.

Download full-text PDF

Source
http://dx.doi.org/10.7863/ultra.32.8.1471DOI Listing

Publication Analysis

Top Keywords

subcutaneous fat
16
target lesion
16
particulate concentration
12
fat echogenicity
12
spinal needle
12
anechoic target
12
concentration gelatin-based
8
sonographically guided
8
lesion biopsy
8
ultrasound phantom
8

Similar Publications

Background: Cryolipolysis is an effective, well-tolerated noninvasive subcutaneous fat reduction treatment.

Objective: Assess participant satisfaction, effectiveness, and safety of a dual-applicator cryolipolysis system that can deliver simultaneous treatments.

Materials And Methods: Adult participants received treatment to the abdomen/flanks (midsection).

View Article and Find Full Text PDF

Background And Aim: The search for sustainable and cost-effective protein alternatives to soybean meal in livestock diets has led to the exploration of legumes such as faba beans [FBs] ( L.). This study investigated the effects of dietary inclusion of FBs on carcass traits, meat quality, and selected blood parameters in Awassi lambs.

View Article and Find Full Text PDF

Background: Disturbances in lipid metabolism are usually associated with hyperlipidemia, which is commonly observed in donkeys with inappetence or anorexia. The diagnostic utility of ultrasound measurements of croup fat thickness (CFT) and relative liver echogenicity for lipomobilization in donkeys with fasting-induced hyperlipidemia was investigated. A prospective observational control study involving 25 donkeys was conducted, and the animals were randomly assigned to a fasting group (FG, n = 20) and a control group (CG, n = 5).

View Article and Find Full Text PDF

Objective: This study aimed to create and validate a nomogram to predict early recurrence (ER) in Colorectal cancer (CRC) patients by combining CT-derived abdominal fat parameters with clinical and pathological characteristics.

Methods: We conducted a retrospective analysis of 206 CRC patients, dividing them into training (n = 146) and validation (n = 60) cohorts. We quantified abdominal fat parameters, including subcutaneous adipose tissue index (SATI) and visceral adipose tissue index (VATI), using semi-automatic software on CT images at the level of the third lumbar vertebra (L3).

View Article and Find Full Text PDF

Objectives: The escalating global incidence of obesity, cardiometabolic disease and sarcopenia necessitates reliable body composition measurement tools. MRI-based assessment is the gold standard, with utility in both clinical and drug trial settings. This study aims to validate a new automated volumetric MRI method by comparing with manual ground truth, prior volumetric measurements, and against a new method for semi-automated single-slice area measurements.

View Article and Find Full Text PDF