Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Soft liners are materials that can be advocated successfully to manage clinical situations like atrophic edentulous ridges with flabby displaceable tissues and in cases of severely resorbed ridges which adversely affect the retention and stability of complete dentures and further enhance bone loss. Soft liner provides a cushioning effect and distributes uniform occlusal forces to compromised residual ridges. In this paper a modified technique of soft liner application in mandibular denture has been discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3603830PMC
http://dx.doi.org/10.1136/bcr-2012-007656DOI Listing

Publication Analysis

Top Keywords

soft liner
12
modified technique
8
technique soft
8
liner application
8
soft
4
application soft
4
soft liners
4
liners materials
4
materials advocated
4
advocated manage
4

Similar Publications

Background and objectives With the continuous presence of microflora, saliva, and frequent intake of coloured food, the colour stability of any aesthetic material may become compromised. Hence, the present study was conducted to evaluate the influence of tea, coffee, and turmeric solutions on the colour stability of commercially available heat-cured and autopolymerizing denture base acrylic resins as well as a soft lining material. Methods Twenty-four rectangular samples measuring 20 mm × 15 mm × 2 mm were prepared for each type of test material.

View Article and Find Full Text PDF

The mechanical behavior of prosthetic liners significantly influences stress distribution, soft tissue protection, and the overall efficiency of the prosthetic. While extensive research has been conducted on liner materials, the impact of liner thickness (2 mm, 4 mm, and 6 mm) on biomechanical response remains underexplored. This study utilizes finite element analysis in Abaqus to investigate how liner material (Gel vs.

View Article and Find Full Text PDF

Anterior Approach Total Ankle Arthroplasty with Patient-Specific Cut Guides.

JBJS Essent Surg Tech

August 2025

Department of Orthopaedics, Faculty of Medicine, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada.

Background: Over the last 30 years, total ankle arthroplasty (TAA) has become a viable surgical option for end-stage ankle arthritis. The aim of TAA is to relieve pain and preserve ankle joint range of motion, which, by definition, shields adjacent joints. Alignment is essential for the longevity and survival of TAA, since malalignment of TAA components can cause abnormal loading patterns with subsequent polyethylene wear and early implant failure.

View Article and Find Full Text PDF

The thin spray-on liner (TSL) is widely used in the seal engineering of mines. TSL with high bearing capability is a new method that can be used to replace metal mesh in the roadway support of underground coal mines. This method exhibits the advantages of fast development, automation, and applicability of geo-conditions.

View Article and Find Full Text PDF

Background: Dislocation is a common complication after head and liner exchange. Although surgical approach has been shown to influence instability rate following primary total hip replacement, the same has not been demonstrated for head and liner exchange. The effect of additional soft tissue release to achieve exposure in revision surgery has been implicated in this finding.

View Article and Find Full Text PDF