Electrical capacitance as a rapid and non-invasive indicator of root length.

Tree Physiol

CSIRO Land and Water, EcoSciences Precinct, Dutton Park, QLD 4102, Australia.

Published: January 2013


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Measurement of tree root systems by conventional methods is a Herculean task. The electrical capacitance method offers a rapid and non-destructive alternative, but it has largely been restricted to herbaceous species. The Dalton Model has been the main concept for understanding equivalent root circuitry; it proposed that roots were cylindrical capacitors with epidermis and xylem being the external and internal electrodes. Capacitance (C) therefore varied in proportion to root surface area (A), mass (M), length (L) and relative permittivity of the plant tissue ε(r). We used the capacitance method on forest and plantation trees (13 to circa 100 y.o.) in situ to test hypotheses derived from implicit assumptions about tree-root-soil circuitry. We concluded: C was not confounded by intermingled root systems; C was strongly related to diameter at breast height (DBH); C was less strongly related to DBH for multiple species at the same site; and C was a poor indicator of DBH, M and L across species, ages and sites. We proposed that ε(r) was proportional to root tissue density ρ and fitted a model with P < 0.05 and R(2) = 0.70 when the three immature (13 y.o.) trees were excluded. There was no significant difference (P = 0.28) between the parameters of the tree model (excluding the immature trees) and one of the same form fitted to data from bean (Vicia faba L.; R(2) = 0.55). Together, the data sets suggested (R(2) = 0.94; n = 26) that there may exist a general relationship of this form applied over two orders of magnitude of L.

Download full-text PDF

Source
http://dx.doi.org/10.1093/treephys/tps115DOI Listing

Publication Analysis

Top Keywords

electrical capacitance
8
root systems
8
capacitance method
8
root
6
capacitance rapid
4
rapid non-invasive
4
non-invasive indicator
4
indicator root
4
root length
4
length measurement
4

Similar Publications

Soft conductive composites are significant components of soft and wearable electronics. Existing soft conductive composites encounter difficulties in attaining 10% of copper's electrical conductivity while maintaining high stretchability. In this work, a novel "soft conductive junction" concept is introduced to overcome the conductivity-stretchability trade-off.

View Article and Find Full Text PDF

Graphene/mesoporous carbon/ZIF-derived carbon heterostructures interface-reinforced assembly for capacitive energy storage.

Chem Commun (Camb)

September 2025

State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China.

We report the synthesis of three-dimensional (3D) graphene/mesoporous carbon/ZIF-derived microporous carbon (G/MC/ZDC-A) heterostructures through an interface-reinforced assembly. This hierarchical architecture synergistically integrates 2D graphene nanosheets with 0D ZDC nanoparticles a mesoporous carbon "binder", effectively mitigating the agglomeration issue while establishing continuous charge transport pathways. When configurated as symmetric supercapacitors with EMIMBF electrolyte, the obtained G/MC/ZDC-A demonstrates decent capacitive performance: a high specific capacitance (240 F g at 0.

View Article and Find Full Text PDF

In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass.

View Article and Find Full Text PDF

We report the performance of solid-state ceramic supercapacitors (SSCs) based on a novel composite electrolyte comprising aluminum-doped lithium lanthanum titanate perovskite, LiLaTiAlO (Al-doped LLTO), and the ionic liquid 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIM BF). Rietveld refinement of X-ray diffraction data confirms the preservation of the tetragonal perovskite phase after Al substitution, indicating structural stability of the host lattice. X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy further corroborate the successful incorporation of Al without forming secondary phases.

View Article and Find Full Text PDF

Bacterial detection is crucial for accurate clinical diagnostics and effective environmental monitoring. Particularly, , a pathogenic bacterium, can cause a wide range of infections, including meningitis, bloodstream infections, pneumonia, urinary tract infections, and wound or surgical site infections. Herein, a polypyrrole (PPy) functionalized TiCT -tin dioxide nanoparticle (SnO NPs) nanocomposite-based hybrid capacitive electrode for the electrochemical detection of ATCC 700603 is developed.

View Article and Find Full Text PDF