Influence of minerals on the taste of bottled and tap water: a chemometric approach.

Water Res

Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona, 18-26, 08026 Barcelona, Spain.

Published: February 2013


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Chemometric analysis was performed on two sets of sensory data obtained from two separate studies. Twenty commercially-available bottled mineral water samples (from the first study) and twenty-five drinking tap and bottled water samples (from the second study) were blind tasted by trained panelists. The panelists expressed their overall liking of the water samples by rating from 0 (worst flavor) to 10 (best flavor). The mean overall score was compared to the physicochemical properties of the samples. Thirteen different physicochemical parameters were considered in both studies and, additionally, residual chlorine levels were assessed in the second study. Principal component analysis performed on the physicochemical parameters and the panelists' mean scores generated models that explain most of the total data variance. Moreover, partial least squares regression of the panelists' sensory evaluations of the physicochemical data helped elucidate the main features underlying the panelists' ratings. The preferred bottled and tap water samples were associated with moderate (relatively to the parameters mean values) contents of total dissolved solids and with relatively high concentrations of HCO₃⁻, SO₄²⁻, Ca²⁺ and Mg²⁺ as well as with relatively high pH values. High concentrations of Na⁺, K⁺ and Cl⁻ were scored low by many of the panelists, while residual chlorine did not affect the ratings, but did enable the panel to distinguish between bottled mineral water and tap water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2012.10.040DOI Listing

Publication Analysis

Top Keywords

water samples
20
tap water
12
bottled tap
8
analysis performed
8
bottled mineral
8
mineral water
8
second study
8
physicochemical parameters
8
residual chlorine
8
high concentrations
8

Similar Publications

Background: In 2023, Mayotte, a French department in the Mozambique channel, experienced a long drought that led to potable water restrictions. Although the French vaccination schedule makes polio vaccination compulsory for children, the large proportion of migrants on the island coupled with the water crisis raised concerns about the establishment of poliovirus transmission chains. Therefore, a surveillance was implemented to detect polioviruses in sewage sampled in the two main wastewater treatment plants.

View Article and Find Full Text PDF

A water-soluble NIR-II fluorescent probe for non-invasive real-time detection of blood ATP optoacoustic and fluorescence imaging.

J Mater Chem B

September 2025

State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.

Adenosine triphosphate (ATP) is a critical biomolecule in cellular energy metabolism, with abnormal levels in the bloodstream linked to pathological conditions such as ischemia, cancer, and inflammatory disorders. Accurate and real-time detection of ATP is essential for early diagnosis and disease monitoring. However, conventional biochemical assays and other techniques suffer from limitations, including invasive sample collection, time-consuming procedures, and the inability to provide dynamic, monitoring.

View Article and Find Full Text PDF

Optimization of the measurement method for airborne endotoxins in workplace atmospheres: experiments using laboratory-generated bioaerosols.

Ann Work Expo Health

September 2025

Laboratoire de Métrologie des Aérosols, INRS, 54519 Vandœuvre-lès-Nancy Cedex, France.

Endotoxins are components of the outer membrane of bacteria that can become airborne during aerosol-generating work activities and cause adverse effects on workers' health. Filtration is the sampling method recommended by the EN 14031 standard for endotoxin measurements in workplace atmospheres. However, there are still differences in terms of practice regarding certain parameters of the measurement method.

View Article and Find Full Text PDF

Efficient and low-cost removal of dissolved organic phosphorus by visible light-enhanced Ti electrocoagulation with self-generated rutile photocatalysts.

Water Res

August 2025

State Key Laboratory of Environmental Aquatic Chemistry, Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.

Phosphorus is recognized as a major pollutant in municipal and domestic wastewater, but the effective removal of organic phosphorus (OP) using conventional wastewater treatment technologies is difficult. Herein, a novel visible light-enhanced Ti electrocoagulation (EC) technology was proposed for the removal of OP using 2-amino-ethyl phosphonic acid (AEP) as a model compound to elucidate the removal efficiency and mechanisms. The results showed that the irradiation under visible light (670 Lux) effectively enhanced the removal of AEP by Ti EC.

View Article and Find Full Text PDF

Liquid chromatography has advanced considerably since its introduction in the 1970s, with reversed-phase liquid chromatography (RPLC) becoming the dominant technique for separating non-volatile molecules. A key strategy for optimising separation conditions is the modelling of chromatographic retention from experimental data. Traditionally, this is achieved by fitting model parameters for each solute, resulting in individual solute models (ISMs).

View Article and Find Full Text PDF